• Title/Summary/Keyword: Dong-Office

Search Result 878, Processing Time 0.031 seconds

Development of Yeongdong Heavy Snowfall Forecast Supporting System (영동대설 예보지원시스템 개발)

  • Kwon, Tae-Yong;Ham, Dong-Ju;Lee, Jeong-Soon;Kim, Sam-Hoi;Cho, Kuh-Hee;Kim, Ji-Eon;Jee, Joon-Bum;Kim, Deok-Rae;Choi, Man-Kyu;Kim, Nam-Won;Nam Gung, Ji Yoen
    • Atmosphere
    • /
    • v.16 no.3
    • /
    • pp.247-257
    • /
    • 2006
  • The Yeong-dong heavy snowfall forecast supporting system has been developed during the last several years. In order to construct the conceptual model, we have examined the characteristics of heavy snowfalls in the Yeong-dong region classified into three precipitation patterns. This system is divided into two parts: forecast and observation. The main purpose of the forecast part is to produce value-added data and to display the geography based features reprocessing the numerical model results associated with a heavy snowfall. The forecast part consists of four submenus: synoptic fields, regional fields, precipitation and snowfall, and verification. Each offers guidance tips and data related with the prediction of heavy snowfalls, which helps weather forecasters understand better their meteorological conditions. The observation portion shows data of wind profiler and snow monitoring for application to nowcasting. The heavy snowfall forecast supporting system was applied and tested to the heavy snowfall event on 28 February 2006. In the beginning stage, this event showed the characteristics of warm precipitation pattern in the wind and surface pressure fields. However, we expected later on the weak warm precipitation pattern because the center of low pressure passing through the Straits of Korea was becoming weak. It was appeared that Gangwon Short Range Prediction System simulated a small amount of precipitation in the Yeong-dong region and this result generally agrees with the observations.

The Effects of Apartment Office Managers' Servant Leadership on the Residents' Satisfaction and Housing Management Company Contract Renewal Ratio (공동주택 관리소장의 서번트 리더십이 입주자만족도와 관리업체 재계약율에 미치는 영향)

  • Lee, Jae-Young;Lee, Do-Hwa;Choi, Seo-Hyun
    • Journal of the Korean housing association
    • /
    • v.27 no.5
    • /
    • pp.45-54
    • /
    • 2016
  • This study aims to verify the effects of the apartment office managers' servant leadership on the residents' satisfactions and housing management company contract renewal ratio, and to examine whether the number of apartment units and the apartments' average size have the moderating effects upon the relationship between servant leadership and the residents's satisfaction and housing management company contract renewal ratio. For the purpose of testing the hypotheses, the questionnaire survey was conducted targeting 1,000 apartment office staffs and 8,000 apartment residents of 200 apartment complex in the region of Ulsan, Kyungnam, and Busan, and the statistical analyses were carried out for the useful questionnaires of 961 apartment office staffs and 7,119 apartment residents. The main results are as follows: First, the higher the office managers servant leadership is, the higher the residents' satisfactions. Second, the number of apartment units and the average size have moderating effects on the relationship between the office managers' servant leadership and housing management company contract renewal ratio. Finally, the summary, implications, and limitations of this study, and the future research direction were discussed in the conclusion.

Effective Performance Analysis of Disease-oriented Translational Research from a Point of View of Biotechnology (생명공학기술적 관점에서 질병중심 중개연구의 효율적 성과분석에 대한 실증연구)

  • Cheon, Su-Hwan;Jung, Sung-Chul;Je, Young-Tae;Kim, Gi-Tae;Kim, Myung-Hwan;Park, Seong-Ho;Jeon, Hye-Kyoung;Kwon, Jun-Young;Kim, Dong-Il;Kim, Dong-Seok;Lee, Kyung-Min;Sun, Kyung
    • KSBB Journal
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Recently, translational research (TR) in health technology (HT) has been considered as an emerging alternative research system for the improvement of human health. TR from bench to bedside involves a strong bidirectional relationship between basic science discovery and clinical practice. To support R&D planning and policy in HT effectively, the performance of TR programs was analyzed and evaluated in a R&D project on health and medical technology. TR programs were classified into three parts: unilateral TR, bilateral TR and multilateral TR. Bibliometrics and citation analysis were performed to assess research papers and gather information for the performance analysis of TR programs. In addition, both quantitative and qualitative analysis were successfully carried out using ISI Web of Science, Google Scholar Citations, SCOPUS and Knowledgematrix. In conclusion, the performance analysis of TR programs could significantly improve the efficiency of R&D plans, R&D management and evaluation for a safe and healthy life.

Recommended Practice for Demand Factor by Feature Parameters and Regression Analysis depending on Power Consumption Characteristics in Office Buildings (사무소용빌딩의 전력소비특성을 고려한 특징파라메터 및 회귀분석을 통한 조명 및 일반동력부하의 수용률 분석)

  • Kim, Se-Dong;Nam, Ki-Beom;Jung, Hyung-Yong;Shin, Hwa-Young;Kim, Sung-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.331-336
    • /
    • 2005
  • It is increased electrical energy consumption with the development of intelligence society in the office buildings and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 54 office buildings and 34 electrical design offices. In this dissertation, it is necessary to analyse the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried linear and nonlinear regression analysis.

  • PDF

The Characteristics of HVAC Noise in Office Buildings (사무소 건물의 공조설비소음 특성)

  • Do, Young-Ju;Kim, Dong-Gyu;Kim, Heung-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.59-66
    • /
    • 1989
  • This study aims to provide the basic data useful in assessing indoor-noise and designing sound devices in office buildings of HVAC system. The measurements of HVAC noise were carried out in office room and mechanical room. The performance of absorptive chamber and side branch was also estimated in the office buildings which have HVAC noise problems. The results of experiments show that the NR value of indoor HVAC noise is rather higher than that of ISO recommendations at the frequencies below 500Hz. In addition, the results indicated that the absorptive chamber attenuates noise over broad band frequencies and side branch reduces noise at the special resonant frequency.

  • PDF

Recommended Practice for Demand Factor and Maximum Utilization Factor by Feature Parameters and Regression Analysis depending on Power Consumption Characteristics in Office Buildings (사무소용빌딩의 전력소비특성을 고려한 특징파라메터 및 회귀분석을 통한 수용률과 변압기최대이용률 비교 분석)

  • Kim, Se-Dong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.241-244
    • /
    • 2007
  • It is increased electrical energy consumption with the development of intelligence society in office buildings and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 132 office buildings. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried linear and nonlinear regression analysis.

  • PDF

Concentrations of Dextromethorphan in Urine and Blood of Two Crime Suspects

  • Rhee, Jong-Sook;Choi, Dong-Ki;Yang, Hee-Jin;Koo, Ki-Ser
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.394.3-395
    • /
    • 2002
  • Dextromethorphan (Romilar. DEX) is a synthetic analogue of codeine. is not classified as a narcotic and is used only for its antitussive effects in Korea. The daily intake by adults range up to 120mg. Usually in the case of traffic accident. alcohol concentration of blood is analyzed in Korea. but drug tests (medicine, narcotic. alcohol) are submitted in Australia. In crimes of violence (2 examples), a traffic and a murder accident. drug testing in urine and blood was performed. (omitted)

  • PDF

A Study on the Environmental Load of Office Buildings in Seoul

  • Lee, Sang-Hyung;Lee, Yun-Gyu;Yang, Kwan-Seob;Ahn, Tae-Kyung;Lee, Seung-Eon;Park, Hyo-Soon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.58-64
    • /
    • 2001
  • This study is to examine the emission quantity of $CO_2$ gas as the environmental load in office buildings. After the investigation of monthly consumption of each energy source(electricity and natural gas), it is analyzed that the $CO_2$ emission quantity of 34 office buildings surveyed is 22.4 kg-c/$m^2$-year, which consists of 17.5 kg-c/$m^2$-year by consurunlelectncif. and 4.9 kg-c/$m^2$-year by consuming natural gas. And the $CO_2$ emission quantity of each load in those buildings consists of 68% emitted by general electricity, 16% by cooling load and 16% by beating load. It is also proposed that the $CO_2$ emission quantity of cooling and heating load is profoundly pertinent to the variation of outdoor temperature.

  • PDF

Histopathological Observations on Viral Encephalomyelitis in Suckling Piglets Raised in Korea (포유자돈(哺乳仔豚)에 발생(發生)한 Viral Encephalomyelitis의 병리조직학적관찰(病理組織學的觀察))

  • Kim, Soon Bok;Park, Keun Sik;Shin, Dong Gyu;Lee, Chang Ku
    • Korean Journal of Veterinary Research
    • /
    • v.20 no.1
    • /
    • pp.25-27
    • /
    • 1980
  • The outbreak of viral encephalomyelitis (Talfan disease) in suckling piglets was diagnosed pathologically for the first time in Korea. The clinical signs of affected sucklings were very high morbidity without death, and fever ($39^{\circ}C$ or higher) with incoordination of the rear limbs and paresis, while no specific gross lesions were observed at autopsy. Histopathological changes were confined to the nervous system, and were of the nature of a nonsuppurative and nondemyelinating encephalomyelitis which is usual for the viral encephalitis. It was characterized by perivascular cuffing, meningitis, neuronal degeneration, neuronophagia and glial nodules in the brain and spinal cord.

  • PDF

A study of LCA(Life Cycle Assessment) to a office building remodeling - Focused on Electrical Equipment - (사무소건축 리모델링에서의 전과정 평가에 관한 연구 - 전기 부분을 중심으로 -)

  • Lee, Seon-Dong;Yoo, Ho-Chun
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.3
    • /
    • pp.85-92
    • /
    • 2004
  • Environmental issues become one of today's central concerns due to draining natural resources and environmental pollution. Architecture is given a great deal of weight on the evoking environmental pollution. In this point of view, polluting factors in architectural planning and construction were predicted in advance and alternative plans were studied, In investigation of alternative plans, both environmental pollution and economical efficiency of various alternatives were considered. A office building was analyzed for energy consumption and construction environmental load by appling LCA. Applying LCA to a office building includes a total amount of materials and energy consumption, environmental impacts and economical efficiency evaluation. In present study, LCA applied to electrical part of a office building and economical efficiency evaluation was considered.