• 제목/요약/키워드: Domestic water use

Search Result 302, Processing Time 0.022 seconds

Use of Na+/K+ATPase in Maceobrachium nipponnese as a biomaker of lead pollution in aquatic ecosystem (수서생태계 납오염에 대한 생체지표로서 Maceobrachium nipponnese내 Na+/K+ATPase의 활용)

  • Chung, Myung-Kiu;Kim, Hak-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.4
    • /
    • pp.395-400
    • /
    • 2002
  • Lead is one of the most toxic metal and is detectable in practically all phases of environment and in all biological system. Transport, industrial and domestic waste products are the main sources of this pollutant. Ingested lead is rapidly absorbed and widely distributed throughout the body, causing extensive tissue damage. In this study, we chose the freshwater decapods Maceobrachium nipponnese as a sensitive indicator organism for environmental pollution. In order to investigate the possibility in use of $Na^+/K^+ATPase$ activity as a biomarker of lead pollution, we tested the acute toxicity of lead to Maceobrachium nipponnese. The $LC_{50}(96hr)$ value for lead in Maceobrachium nipponnese was found to be $446{\mu}g/L$ with the 95% confidence limits. The lead exposure group at $LC_{50}$ showed a significant $Na^+/K^+ATPase$ inhibition, depending on the exposure time. Comparision of several concentrations of lead revealed that the $Na^+/K^+ATPase$ activity in Maceobrachium nipponnese was significantly decreased in a concentration dependent manner. These results suggest that $Na^+/K^+ATPase$ activity in Maceobrachium nipponnese may possibly be used as a biomarker of lead pollution in aquatic ecosystem.

Economic Evaluation of Air-side Economizer System for Data Center (데이터센터의 외기도입 냉방시스템 적용에 따른 경제성 평가)

  • Park, Seonghyun;Seo, Janghoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.4
    • /
    • pp.145-150
    • /
    • 2014
  • Many studies are being conducted with the aim of reducing the energy consumption in data centers, which are one of the highest consumers of energy. The use of an air-side economizer system that uses external air during intermediate and winter seasons is being considered for reducing the energy consumption of air conditioners. In this study, using the energy simulation, we evaluated the energy performance of a central chilled water cooling system and air-side economizer system in domestic data centers. Further, the cost-effectiveness of the air-side economizer was analyzed through Life-Cycle Cost Analysis. The results showed that with the use of air-side economizer systems, the energy costs increased as the applied filter grade increased; however, unlike existing central chilled water systems, it would break even within 2 years.

CFD Performance analysis of Micro Tubular-type hydro turbine by blade shape (블레이드 형상 변화에 따른 마이크로 튜블러 수차의 CFD 성능해석)

  • Park, Ji-Hoon;Hwang, Young-Cheol;Mo, Jang-Oh;Kim, You-Taek;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.206.1-206.1
    • /
    • 2011
  • Recently, various developments in the area of small hydropower have being made and small hydro turbines are suitable for domestic use because it is a clean and renewable energy source. A small hydropower generator produces power by using the different water pressure levels in pipe lines and energy which was initially wasted by use of a reducing valve at the end of the pipeline is instead collected by a tubular-type hydro turbine in the generator. In this study, in order to acquire the performance of tubular-type hydro turbine applied, the output power, head, efficiency characteristics due to the different guide vane and runner vane angle are examined in detail. Moreover, influences of pressure and velocity distributions with the variation of guide vane and runner vane angle on turbine performance are investigated by using a commercial CFD code.

  • PDF

Recognition and Practice of middle school students' mothers on Prevention of Environmental Pollution in Cheong-ju (청주 지역 중학생 자모들의 환경오염 방지에 대한 의식과 실천 연구)

  • 김기남;권수애
    • Hwankyungkyoyuk
    • /
    • v.8 no.1
    • /
    • pp.66-80
    • /
    • 1995
  • The purpose of this study was to investigate the housewives's recognition and practice on prevention of environmental pollution. The subjects of this study were 250 housewives, school students' mothers, living in Cheong-ju. Major findings were as follows: 1. In washing their faces and brushing their teeth, they saved the water very well, but in taking bath, washing the dished, using the water of the lavatory they did not save the water so well. 2. The kinds of the cleansers differed in taking a bath, washing the hair, and doing the laundry respectively : what they use most was hard soaps in taking bath, liquid cleansers mixed with shampoo and linse in washing the hair, and synthetic powder detergent in laundrying. They used more synthetic detergent than natural soaps, which is known to be a cause of water pollution. Especially, when they cleansed, they did not use a measuring cup. It resulted in the waste of detergent and accelerating of water pollution. Therefore, the environmental education for them was very urgently needed. 3. In handling domestic waste, the separate collection rate of empty bottles and old newspapers was very high, but that of used phone-call cards and used batteries was extremely low. It was truly nessesary to educate and step up publicic activities on the separate collection of phone-call cards and batteries caused environmental pollution. 4. The housewives had much knowledge about environmental pollution, but they did not practice it so well in their home. 5. The housewives made more effort than their children in preventing environmental pollution and saving resources. In conclusion, what is most important for solving environmental problem was for each citizen to make an effort to prevent environmental pollution, and the government's support and producing the atmosphere of the society for this was really needed.

  • PDF

Development and Assessment of Environmental Water Seasonal Outlook Method for the Urban Area (도시지역에 대한 환경용수의 계절전망 기법 개발 및 평가)

  • So, Jae-Min;Kim, Jeong-Bae;Bae, Deg-Hyo
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.1
    • /
    • pp.67-76
    • /
    • 2018
  • There are 34 mega-cities with a population of more than 10 million in the world. One of the highly populated cities in the world is Seoul in South Korea. Seoul receives $1,140million\;m^3/year$ for domestic water, $2million\;m^3/year$ for agricultural water and $6million\;m^3/year$ for industrial water from multi-purpose dams. The maintenance water used for water conservation, ecosystem protection and landscape preservation is $158million\;m^3/year$, which is supplied from natural precipitation. Recently, the use of the other water for preservation of water quality and ecosystem protection in urban areas is increasing. The objectives of this study is to develop the seasonal forecast method of environmental water in urban areas (Seoul, Daejeon, Gwangju, Busan) and to evaluate its predictability. In order to estimate the seasonal outlook information of environmental water from Land Surface Model (LSM), we used the observation weather data of Automated Synoptic Observing System (ASOS) sites, forecast and hind cast data of GloSea5. In the past 30 years (1985 ~ 2014), precipitation, natural runoff and Urban Environmental Water Index (UEI) were analyzed in the 4 urban areas. We calculated the seasonal outlook values of the UEI based on GloSea5 for 2015 year and compared it to UEI based on observed data. The seasonal outlook of UEI in urban areas presented high predictability in the spring, autumn and winter. Studies have depicted that the proposed UEI will be useful for evaluating urban environmental water and the predictability of UEI using GloSea5 forecast data is likely to be high in the order of autumn, winter, spring and summer.

PERFORMANCE EVALUATION OF BUBBLE PUMP USED IN A PASSIVE SOLAR WATER HEATER SYSTEM

  • Xuesong, Li;Park, Gi-Tae;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2309-2314
    • /
    • 2007
  • The application analysis of bubble pump on the domestic solar water heater system is presented. The system investigated in this study is a passive device, self pumping and self regulating. It was test to use the bubble pump on solar water heater system. The test experiment has been taken on the existed vacuum tube about the efficiency, working fluid temperature and pressure and circulated power. In order to check the working temperature and working pressure effectively, the bubble pump was test separated from the solar water heater. The equipment consists of the bubble pump, heater and heat exchanger. The main structure of bubble pump was design depend on the character of two phase flow. The complete system was instrumented to measure pressures, temperatures and flow-rates at various locations. The theory analysis of design bubble pump has been given and the experiment design has been included in the paper.

  • PDF

Design Consideration about Large Caliber Piping of Polyethylene Material (폴리에틸렌 소재의 대구경 배관 설계 고찰)

  • Kim, Eung-Soo;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.44-49
    • /
    • 2013
  • As the polyethylene of high strength and ductility stabilized chemically has been mass-produced, it is spreading widely as material of industrial piping and water service piping. Recently, High density polyethylene (HDPE) pipe has been used even in water supply system of plant as buried pipe instead of cast iron pipe in domestic, but HDPE pipe has a probability of occurrence of damage if plant design and operating conditions are not considered. As a result of reviewing with respect of system design engineering based on operating conditions and verification test results, the specific design criteria for the use of HDPE piping in fire water supply system need to be established because of the possibility of crack damage due to water hammer.

Developing a composite vertical flow constructed wetlands for rainwater treatment

  • Ahmed, Sanjrani Manzoor;Zhou, Boxun;Zhao, Heng;Zheng, You Ping;Wang, Yue;Xia, Shibin
    • Membrane and Water Treatment
    • /
    • v.11 no.2
    • /
    • pp.87-95
    • /
    • 2020
  • The worldwide shortage of water resources is a major environmental issue. Using pure water for drinking and domestic purposes is a bigger issue than other environmental issues. Industrialization and Urbanization have even polluted rainwater. In China, when it rains, rainwater is stored on the roof or other sources of storage for daily use resulting in pollution. Several studies have been conducted to treat rainwater. The objective of this study is to evaluate the efficiency of constructed wetlands by using ACF as a medium. So, this study aims to treat rainwater in Wuhan city through a Composite Vertical Flow Constructed Wetlands. First, rainwater was stored in the tank while it flows out of the roof, further it is processed in constructed wetlands. The constructed wetlands is consisted with plants Calamus and Chives, adding ACF (prepared from luffa) has achieved great results in this study. Results show that the pollutants have been removed to a considerable level, there were significant differences in removal rates under different HRT at 6h, 9h and 12h respectively. Therefore, Composite Vertical Flow Constructed Wetlands is recommended for total nitrogen and Ammonia nitrogen and total phosphorus.

The characteristics of the Groundwater Quality in Seoul (서울시 지하수 수질특성에 관한 연구)

  • 김익수;엄석원;이재영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.225-228
    • /
    • 2003
  • For the purpose of finding out the distributions of groundwater uses, the effect of facilities on the parameter and the correlations among measurements, various statistical analysis were carried out with the data of groundwater quality measurements from January to December in 2002. 1. The rates of groundwater for drinking water were 10.5% in Yangcheon-Gu, 10.2% in Kangdong-Gu, and 9.9% in Eunpyung-Gu. The rates of other uses of groundwater were shown to be 58.1%(786 wells) for civil defense emergency, 22.1%(299 wells) for contamination-concerning, 9.8%(133 wells) for water quality monitoring, consisting of 90% of all groundwater. 2. The 52.6% of groundwater for drinking were demonstrated to be appropriate while 91.9% for tither uses-domestic, industrial, agricultural uses- were shown to be proper. 3. For drinking water, the average values of colar, turbidity, NH3-N, F, and Fe were 11.216 degree, 2.138 NTU, 2.458mg/l, 0.212mg/1 and 0.507mg/1 respectively. 4. In cases of drinking water wells for emergency, the results of statistical analysis showed that building year of the wells, depth and pumping rate didn't affect on whether it was proper for that use or not. It were shown that there were linear correlations between depth and NO$_3$-N(-0.171) and F ̄(0.332) while the correlation coefficients were 0.381 and -0.169 between the building year of well and depth and pumping rate respectively.

  • PDF

The Inverse Circulation System for Using Treated Waste Water as Instream Flow (하수처리수의 하천유지용수 활용을 위한 역순환시스템의 비교)

  • Kim, Gee-Hyoung;Choi, Gye-Woon;Ahn, Tae-Jin;Kim, Jin-Hong;Shim, Myung-Pil
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.5
    • /
    • pp.863-878
    • /
    • 2003
  • In this paper, it was studied on a device for maintaining the instream flow by using treated waste water from sewage treatment plant, and discussed on using the inverse circulation system in stream for directly utilizing treated waste water as instream flow. This system is to secure insufficient discharge at upstream, as treated water is pumped from treatment plant which is located at down stream. Therefore, it will be improved water quality with simple water treatment plant, as it is composed of optimal system by consist various types of scheme for transporting. Also, influx method of transferred treated water to a stream will be improved water quality by aeration and be shown environmental friendly spaces. It was considered water quality and present using condition to use for maintenance water in stream by treated water. The guide line for application of inverse circulation system in domestic streams is suggested.