Economic Evaluation of Air-side Economizer System for Data Center  

Park, Seonghyun (Department of Architecture, Graduate School of Kookmin University)
Seo, Janghoo (School of Architecture/The Graduate School of Techno Design, Kookmin University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.26, no.4, 2014 , pp. 145-150 More about this Journal
Abstract
Many studies are being conducted with the aim of reducing the energy consumption in data centers, which are one of the highest consumers of energy. The use of an air-side economizer system that uses external air during intermediate and winter seasons is being considered for reducing the energy consumption of air conditioners. In this study, using the energy simulation, we evaluated the energy performance of a central chilled water cooling system and air-side economizer system in domestic data centers. Further, the cost-effectiveness of the air-side economizer was analyzed through Life-Cycle Cost Analysis. The results showed that with the use of air-side economizer systems, the energy costs increased as the applied filter grade increased; however, unlike existing central chilled water systems, it would break even within 2 years.
Keywords
Data center; Air-side economizer system; Economic evaluation; Sensitivity analysis;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Sun, H. S. and Lee, S. E., 2006, Case study of data centers' energy performance, Energy and Buildings, Vol. 38, No. 5, pp. 522-533.   DOI   ScienceOn
2 Covas, M. T., Silva, C. A., and Dias, L. C., 2013, On locating sustainable Data Centers in Portugal:Problem structuring and GIS-based analysis, Sustainable Computing: Informatics and Systems, Vol. 3, No. 1, pp. 27-35.   DOI   ScienceOn
3 Cho, J., Lim, T., and Kim, B. S., 2012, Viability of datacenter cooling systems for energy efficiency in temperate or subtropical regions:Case study, Energy and buildings, Vol. 55, pp. 189-197.   DOI   ScienceOn
4 TRNSYS 17(Transient System Simulation Program, 2011, Solar Energy Lab, Rep., University of Wisconsin-Madison.
5 ASHRAE, 2009, Particulate and Gaseous Contamination in Datacom Environments, Vol. 8.
6 Park, S., Seo, J., Jung, Y. H., Chang, H. J., and Hwang, S. H., 2013, Energy consumption analysis based on filter differential pressure when adopting an air-side economizer system for a data center, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 7, pp. 371-376.   과학기술학회마을   DOI   ScienceOn
7 Donald, G. N., Ted, G. E., and Jerome, P. L., 2004, Study Guide for ENGINEERING ECONOMIC ANALYSIS, 9th ed., Oxford University Press, pp. 71-93.
8 Cho, J. K., Jeong, C. S., and Kim, B. S., 2008, The Planning and Design of the Optimal Cooling System for IT Environments in (Internet) Data Centers, Journal of the Architectural Institute of Korea, Vol. 24, No. 12, pp. 313-320.   과학기술학회마을
9 Cho, J. and Kim, B. S., 2011, Evaluation of air management system's thermal performance for superior cooling efficiency in high-density data centers, Energy and Buildings, Vol. 43, No. 9, pp. 2145-2155.   DOI   ScienceOn