• 제목/요약/키워드: Domestic anthracite

검색결과 38건 처리시간 0.025초

국내 무연탄의 수요개발 가능성 분석 (An Analysis of the Demand Expansion Options for the Domestic Anthracite Coal)

  • 최기련;강희정
    • 에너지공학
    • /
    • 제1권1호
    • /
    • pp.102-110
    • /
    • 1992
  • The determination of production level of the domestic anthracite coal is an important issue in the national energy strategy. It is also closely related to the energy mix scenarios in the future. The objective of the paper is to discuss and analyze the options of expanding anthracite coal demand in the utility sector. The observed options are including; (1) New pulverized system of the 200 and 500 MW level, (2) Atmospheric Fluidized Bed Combustion (AFBC), and (3) Pressurized Fluidized Bed Combustion (PFBC). Special emphasis is placed on the considerations in estimating the effects on the electric system costs and government subsidies when the options are introduced in the utility sector.

  • PDF

유동층 연소로에서 유.무연탄 혼합 연소법을 이용한 국내산 저질 무연탄의 활용에 관한 연구 (A Study on the Use of Low-Grade Domestic Anthracite by Anthracite - Bituminous Coal Blend Combustion in a Fluidized Bed Combustor)

  • 정종현;조상원
    • 한국환경과학회지
    • /
    • 제6권3호
    • /
    • pp.267-276
    • /
    • 1997
  • It has been studded that combustion and the production of air pollution of anthracite - bituminous coal blend In a fluidized bed coal combustor, The objects of thIns study were to investigate mixing characteristics of the particles as well as the combustibility of the low grade domestic anthracite coal and Imported h19h calorific bltununous coal in the fluidized bed coal combustor. They were used as coal samples ; the domestic low grade anthracite coal with heating value of 2,010kca1/kg and the Imported high grade bituminous coal with beating value of 6,520kca1/kg. Also, the effects of air flow rate and anthracite fraction on the reaching time of steady state condition have been studied. The experimental results are presented as follows. The time of reaching to steady state was affected by the temperature variation. The steady state time was about 120 minute at 300sc1h which was the fastest. It has been found that $O^2$ and $CO^2$ concentration were reached steady state at about 100 minute. It has been found that $O^2$ concentration decreased and $CO^2$ concentration increased as the height of fluidlzed bed Increased. It was found that splash zone was mainly located from 25cm to 35cm above distributor. Also, as anthracite traction Increased, the mass of elutrlatlon particles Increased, and $CO^2$ concentration decreased. As gk flow rate Increased,$O^2$ concentration decreased and $CO^2$ concentration increased. Regardless of anthracite fraction and flow rate, the uncombustible weight percentage according to average diameter of elutriation particles were approldmately high In the case of One Particles. As anthracite traction and k now rate Increased, elutriation ratio Increased. As anthracite fraction was increased, exit combustible content over feeding combustible content was Increased. Regardless of anthracite fraction, size distribution of Ued material from discharge was almost constant. Over bed temperature 85$0^{\circ}C$ and excess air 20% , the difference of combution efficiencies were little. It is estimate that the combustion condition In anthracite-bituminous coal blend combustion is suitable at the velocity 0.3m/s, bed temperature 85$0^{\circ}C$, the excess air 20%.

  • PDF

유동층 연소로에서 유$cdot$무연탄 혼합 연소시 대기오염물질 배출에 관한 연구 (A Study on Contaminant Emission and Combustion of Anthracite-Bituminous Coal Blend in a Fluidized Bed Coal Combustor)

  • 조상원;정종현;손병현;김영식;오광중
    • 한국환경보건학회지
    • /
    • 제22권3호
    • /
    • pp.28-36
    • /
    • 1996
  • The objects of this study were to investigate emissions of air pollutant the particles as well as the combustibility of the low grade domestic anthracite coal and imported high-calorific bituminous coal in the fluidized bed coal combustor. The production of air pollution from anthracite-bituminous coal blend combustion in a fluidized bed coal combustor was evaluated. The effects of air velocity and anthracite fraction on the reaching time of steady state condition was also evaluated. We used coal samples the domestic low grade anthracite coal with heating value of 2,010 kcal/kg and the imported high grade bituminous coal with heating value of 6,520 kcal/kg. The experimental results are presented as follows. The time of reaching to steady state was affected by the temperature variation. The steady state time was about 120 minute at 0.3 m/s which was the fastest. It has been found that $O_2$ and $CO_2$ concentration were reached steady state at about 100 minute. As the height of fluidized bed becomes higher, the concentration s of $SO_2$ and $NO_x$ mainly increased. The concentration of freeboard was the highest and emission concentration was diminished. Also, as anthracite fraction increased, the emission of $SO_x$ concentration was increased. But, it has been found that the variation of $NO_x$ concentration with anthracite fraction was negligible and the difference of emission concentration according to air flow rates was negligible, too. It has been found that $O_2$ concentration decreased and $CO_2$ concentration increased as the height of fluidized bed increased. As anthracite fraction increased, the mass of elutriation particles increased, and $CO_2$ concentration decreased. Also, as air velocity increased, $O_2$ concentration decreased and $CO_2$ concentration increased. Regardless-of anthracite fraction and flow rate, the combustible weight percentage in elutriation particles were high in the case of fine particles.

  • PDF

벤치규모 가압유동층연소로에서 석회석에 의한 국내무연탄의 탈황특성 (Desulfurization Characteristics of Domestic Anthracite by Limes at Bench Scale Pressurized Fluidized Bed Combustor .)

  • 한근희;류정인;진경태
    • 대한기계학회논문집B
    • /
    • 제25권10호
    • /
    • pp.1373-1383
    • /
    • 2001
  • The desulfurization characteristics of anthracite in a bench scale pressurized fluidized bed combustor are investigated. The coal used in the experiment is domestic anthracite from Kangwon Taeback area. The desulphurization experiment is performed with limestone from Chungbuk Danyang. The pressure of the combustor is maintained at 6 atm, and the combustion temperatures are 850, 900, and 950$\^{C}$. The superficial gas velocities are 0.9, 1.1, and 1.3 m/s. The excess air ratio is varied from 5 to 35%. The Ca/S mole ratios are 0.5, 1.5, 2.5 and 4.5 mole. All experiments are executed at 2m bed height. Consequently, SO$_2$ concentration in the flue gas is increased with incresing bed temperature and superficial gas velocity. However SO$_2$ concentration is decreased with incresing excess air ratio and Ca/S mole ratio.

석탄유동층연소로에서 분진 발생 및 배출 특성 (Elutriation and Production of Fines in a Fluidized Bed Coal Combustor)

  • 장현태;이종일
    • 한국안전학회지
    • /
    • 제11권2호
    • /
    • pp.96-101
    • /
    • 1996
  • The effects of coal type and mixing fraction of coal on attrition and elutriation were studied in a 15. 5cm diameter fluidized bed coal combustor. The domestic low-grade anthracite coal with heating value 2010kcal/kg and the imported bituminous coal from Australia with heating value of 6520kcal/kg were used as coal sample. It was found from the experimental that the elutriation rate inclosed with an increseing anthracite mixing fraction. The size of elutriated particle had a very wide distribution was found in this experiment. The mean size of elutriated particle increased with decreaseing anthracite mixing fraction.

  • PDF

국내 무연탄 발전소 혼소율 변화에 따른 탈황 특성 연구

  • 김정유;박대영;이재헌;문승재
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.84-87
    • /
    • 2008
  • The sulfur oxides is one of important materials to come about air pollution at thermal plant consuming fossil fuel. The several flue gas desulfurization equipments are installed and operated to decrease sulfur oxides. The flue gas desulfurization of our thermal plant is designed for optimizing flue gas desulfurization technical development and research by Korea Electric Power Research Institute. We operate this desulfurization equipment. Now, our country imports nearly 97 percentage of the energy source and competes with the world for the energy because of the rise of raw materials cost. The fuel cost decrease of power plants is the most important factor of the operation. The fuel used in the experiment is the domestic anthracite from Kangwon Taeback and the bituminous coal from Russia,Taldinsky Mine. This Study is experimental investigations of desulfurization characteristics for domestic anthracite power plant by increasing bituminous coal. We surveyed possible parameters and conducted the performance about desulfurization equipment in Y.D thermal power plant.

  • PDF

순환유동층 보일러에서 무연탄-유연탄의 혼합연소 특성 (Co-combustion Characteristics of Mixed Coal with Anthracite and Bituminous in a Circulating Fluidized Bed Boiler)

  • 정의대;문승재
    • 플랜트 저널
    • /
    • 제6권2호
    • /
    • pp.70-77
    • /
    • 2010
  • This study investigated the characteristics of co-combustion of mixed anthracite (domestic and Vietnam) and bituminous coal (Sonoma, Australia) at circulating fluidized bed boiler in Donghae thermal power plant when mixing ratio of bituminous coal is variable. Co-combustion of bituminous coal contributes to improvement in general combustion characteristics such as moderately retaining temperature of furnace and recycle loop, reducing unburned carbon powder, and reducing discharge concentration of NOx and limestone supply owing to improvement in anthracite combustibility as the mixing ratio was increased. However, bed materials were needed to be added externally when the mixing ratio exceeded 40% because of reduction in generating bed materials based on reduction in ash production. When co-combustion was conducted in the section of 40 to 60% in the mixing ratio while the supplied particles of bituminous coal was increased from 6 mm to 10 mm, continuous operation was shown to be possible with upper differential pressure of 100 mmH2O (0.98 kPa) and more without addition of bed materials for the co-combustion of mixed anthracite and bituminous coal (to 50% or less of the ratio) and that of domestic coal and bituminous coal (to 60% of the ratio).

  • PDF

국내 무연탄 발전소 역청탄 사용시 탈황 특성 연구 (Desulfurization Characteristics for Anthracite Coal Power Plant by Increasing Bituminous Coal Fuel)

  • 김정유;문승재;이재헌
    • 플랜트 저널
    • /
    • 제4권4호
    • /
    • pp.71-77
    • /
    • 2008
  • The sulfur oxides is one of important materials to come about air pollution at thermal plant consuming fossil fuel. The several flue gas desulfurization equipments are installed and operated to decrease sulfur oxides. The flue gas desulfurization of our thermal plant is designed for optimizing flue gas desulfurization technical development and research by Korea Electric Power Research Institute. We operate this desulfurization equipment. Now, our country imports nearly 97 percentage of the energy source and competes with the world for the energy because of the sudden rise of raw materials cost. The fuel cost decrease of power plants is the most important factor of the operation. The fuel used in the experiment is the domestic anthracite from Kangwon Taeback and the bituminous coal from Taldinsky Mine in Russia. This Study is experimental investigations of desulfurization characteristics for domestic anthracite power plant by increasing bituminous coal. We surveyed possible parameters and conducted the performance about desulfurization equipment in Yong Dong thermal power plant.

  • PDF

무연탄(無煙炭)과 페놀수지(樹脂)로부터 제조(製造)된 성형(成形)코크스의 기공율(氣孔率)과 전기저항율(電氣抵抗率) (Porosity and Electrical Resistivity of Formed Cokes Made from Anthracite and Phenolic resin)

  • 이계승;송영준
    • 자원리싸이클링
    • /
    • 제17권5호
    • /
    • pp.19-27
    • /
    • 2008
  • 국산무연탄과 페놀수지를 혼합 소성하여 성형코크스를 제조하고 점결제의 량, 탈수온도 및 시간, 경화온도 및 시간, 소결온도 및 시간, 무연탄의 입도 및 입도 분포, 무연탄의 품위, 플라스틱 혼합율 등을 변화시킬 경우에 있어서 제조되는 코크스의 기공율, 전기 저항률 등의 물성 변화를 연구한 결과 제조된 대부분의 코크스는 $0.3\sim1.2\Omega{\cdot}cm$의 전기저항률과 $10\sim30%$의 기공율 범위에서 각 인자의 영향을 받아 변화함을 확인하였다.

국산무연탄의 소유공기량과 발생연소가스량의 산식에 관한 연구 (A Study on the Calculation Formulae for the Required Air and Combustion Gas of the Domestic Anthracites)

  • 이우환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.28-33
    • /
    • 1981
  • The characteristics of typical 35 kinds of domestic anthracites among 155 kinds are studied to find the calculation formula for the required quantity of air and the combustion gas quantity. 1) The author's calculation formulae are as follows: ${A_0}={\frac{1, 000}{1, 064}}{H_1}+0.086(Nm^3/kg)$ ${G_0}={\frac{1, 000}{1, 110}}{H_1}+0.234(Nm^3/kg)$(1) Theoretically required quantity of air (2) Theoretical quantity of combustion gas 2) Theoretical quantity of air in combustion of domestic anthracite is always estimated more with Rosin's formula than author's one in the typical domestic anthracites which have the lower calorific value between 3, 000-8, 000 Kcal/kg and the difference of the calculated quantity of air becomes small, as the calorific value increases. 3) Theoretical quantity of combustion gas is estimated more by author's formula than by Rosin's one with the domestic anthracites which have more calorific value than 6, 700 Kcal/kg and is estimated less in the under range of the above calorific value. 4) Theoretical quantity of required air and quantity of combustion gas of domestic anthracite show ${\pm}$4% difference by Rosin's formulae in comparison with results of actual analysis, and about ${\pm}$1.5% by the author's one.

  • PDF