Desulfurization Characteristics for Anthracite Coal Power Plant by Increasing Bituminous Coal Fuel

국내 무연탄 발전소 역청탄 사용시 탈황 특성 연구

  • Kim, Jeong-You (Department of Power Engineering, Graduate School of Hanyang University) ;
  • Moon, Seung-Jae (School of Mechanical Engineering, Hanyang University) ;
  • Lee, Jae-Heon (School of Mechanical Engineering, Hanyang University)
  • 김정유 (한양대학교 대학원 파워엔지니어링공학과) ;
  • 문승재 (한양대학교 기계공학부) ;
  • 이재헌 (한양대학교 기계공학부)
  • Received : 2008.08.05
  • Accepted : 2008.09.07
  • Published : 2008.12.30

Abstract

The sulfur oxides is one of important materials to come about air pollution at thermal plant consuming fossil fuel. The several flue gas desulfurization equipments are installed and operated to decrease sulfur oxides. The flue gas desulfurization of our thermal plant is designed for optimizing flue gas desulfurization technical development and research by Korea Electric Power Research Institute. We operate this desulfurization equipment. Now, our country imports nearly 97 percentage of the energy source and competes with the world for the energy because of the sudden rise of raw materials cost. The fuel cost decrease of power plants is the most important factor of the operation. The fuel used in the experiment is the domestic anthracite from Kangwon Taeback and the bituminous coal from Taldinsky Mine in Russia. This Study is experimental investigations of desulfurization characteristics for domestic anthracite power plant by increasing bituminous coal. We surveyed possible parameters and conducted the performance about desulfurization equipment in Yong Dong thermal power plant.

Keywords