• Title/Summary/Keyword: Dog-bone Shape

Search Result 28, Processing Time 0.029 seconds

A SOFT X-RAY STUDY ON THE BONE REMODELLING IN TOOTH MOVEMENT OF DOG (성견의 실험적 치아이동시 골재형성에 관한 연X선학적 연구)

  • Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.587-592
    • /
    • 1995
  • The purpose of this study was to observe the pattern of bone remodellings in the periodontal ligament of dog, in which experimental tooth movement was performed A control and 5 experimental dogs, one and half year in age, were studied. Light force (50-75g) was applied by placing open-coil spring between left mandibular premolars ; heavy force (250-300g), between right mandibular premolars. Experimental dogs were sacrificed at 12 hours, 1, 3 ,7 and 14 days after force application, respectively. And soft X-ray films were obtained and read on the sectioned periodontal tissue around mandibular premolars. The results were as follows. 1. New bone formation began to be observed in tension side at 7-day and increased at 14-day , No difference was observed between light force group and heavy force group. 2. Bone resorption was observed as a shape of destruction of lamina dura at 3-day and increased gradually at 7-day, 14-day.

  • PDF

Awareness Survey of Consumers buying Companion Dog Food through Internet (인터넷을 통한 반려견 식품 구매자의 인식 조사)

  • Son, Eun-Shim
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.574-583
    • /
    • 2020
  • The aim of this study is to investigate the expenditure items and expenses for companion dogs and the appropriate considerations when choosing companion dog food for consumers who purchase dog food through the internet. The survey subjects consisted of 39 males (6.8%) and 532 females (93.2%), and it was found that most women purchase dog food through the internet. According to the age of dog owner, 184 (32.2%) were in their 20s and 241 (42.2%) in their 30s and 146 (25.6%) in their 40s or older. According to the age of the dogs, 200 (35%) were under 3 years old, 202 (35.4%) over 8 years old, and 169 (29.6%) were between 4 and 7 years old. The most preferred ingredient was chicken, regardless of dogs' owner or the dogs' age. Spending less than 100,000 won was most frequency reported, regardless of dog owner and the age of the dog, and major dog food was reported to be purchased in the order of online shopping malls and animal hospitals. In order to improve health function, it was determined that improvement of skin and hair is the most important, and next, was improvement of tooth bone formation and digestibility. When choosing food for companion dogs, nutritional composition of all the products was the most important consideration, followed by brand products with recognition, color, smell, shape, functional improvement products, and price of the products. Therefore, when developing a new product for companion dog food, consideration must be given not only to the nutritional components of all products, but also the brands, color, odor, shape, nutritional balance, functional improvement and price.

Model for the prediction of Roll Force of Roughing Mill considering Width reduction (도그본 고려한 조압연 압연하중 예측모델 개발)

  • Kwak, W.J.;Lee, S.J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.05a
    • /
    • pp.223-225
    • /
    • 2007
  • Online models predicting roll force and forward slip of roughing mill was developed using nondimensional parameters. Using the effective inlet thickness, roll force model take into account the effect of inlet dog-bone shape of slab which take places after width reduction through edger rolling in roughing mill. The prediction accuracy of the proposed model is examined through comparison with measurements.

  • PDF

Displacement-recovery-capacity of superelastic SMA fibers reinforced cementitious materials

  • Choi, Eunsoo;Mohammadzadeh, Behzad;Hwang, Jin-Ha;Lee, Jong-Han
    • Smart Structures and Systems
    • /
    • v.24 no.2
    • /
    • pp.157-171
    • /
    • 2019
  • This study investigated the effects of the geometric parameters of superelastic shape memory alloy (SE SMA) fibers on the pullout displacement recovering and self-healing capacity of reinforced cementitious composites. Three diameters of 0.5, 0.7 and 1.0 mm and two different crimped lengths of 5.0 and 10.0 mm were considered. To provide best anchoring action and high bond between fiber and cement mortar, the fibers were crimped at the end to create spear-head shape. The single fiber cement-based specimens were manufactured with the cement mortar of a compressive strength of 84 MPa with the square shape at the top and a dog-bone shape at the bottom. The embedded length of each fiber was 15 mm. The pullout test was performed with displacement control to obtain monotonic or hysteretic behaviors. The results showed that pullout displacements were recovered after fibers slipped and stuck in the specimen. The specimens with fiber of larger diameter showed better displacement recovering capacity. The flag-shaped behavior was observed for all specimens, and those with fiber of 1.0 mm diameter showed the clearest one. It was observed that the length of fiber anchorage did not have a significant effect on the displacement recovery, pullout resistance and self-healing capacity.

Reduction of Bowed Tibia Fracture by Fixation with Kirschner and Cerclage Wires in a Dog: A Case Report (Kirschner 철사와 원형 철사를 이용하여 개의 휘어진 경골 골절을 정복한 증례)

  • Uhm, Mi-Young;Kim, Young-Ki;Wang, Ji-Hwan;Lee, Hee-Chun;Lee, Hyo-Jong;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.25 no.5
    • /
    • pp.408-410
    • /
    • 2008
  • A four months old, 3.6 kg intact female Miniature Dachshund dog was referred for non-weight bearing lameness at right hind limb due to car accident. On physical examination, the patient was non-weight bearing on the right hind leg and had moderate swelling in the proximal to middle tibia region. There was palpable crepitus. Radiographs revealed a slightly displaced, spiral, oblique fracture involving the proximal diaphyseal region of the right tibia. Fibular fracture was also noted. Internal fixation was performed to repair the fracture. Due to bowed shape of fractured tibia, it was not possible to apply K-wire, containing appropriate diameter ($60{\sim}80%$ of bone marrow diameter) for intramedullary fixation. We fixed the bowed tibia fracture using a smaller diameter (30% of bone marrow diameter) K-wire with cross pins and cerclage wires. Four weeks after the operation, radiographs demonstrated healing of the tibia fracture as well as the fibular fracture.

Periodontal tissue reaction to customized nano-hydroxyapatite block scaffold in one-wall intrabony defect: a histologic study in dogs

  • Lee, Jung-Seok;Park, Weon-Yeong;Cha, Jae-Kook;Jung, Ui-Won;Kim, Chang-Sung;Lee, Yong-Keun;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.2
    • /
    • pp.50-58
    • /
    • 2012
  • Purpose: This study evaluated histologically the tissue responses to and the effects of a customized nano-hydroxyapatite (n-HA) block bone graft on periodontal regeneration in a one-wall periodontal-defect model. Methods: A customized block bone for filling in the standardized periodontal defect was fabricated from prefabricated n-HA powders and a polymeric sponge. Bilateral $4{\times}{\times}4{\times}5$ mm (buccolingual width${\times}$mesiodistal width${\times}$depth), one-wall, critical-size intrabony periodontal defects were surgically created at the mandibular second and fourth premolars of five Beagle dogs. In each dog, one defect was filled with block-type HA and the other served as a sham-surgery control. The animals were sacrificed following an 8-week healing interval for clinical and histological evaluations. Results: Although the sites that received an n-HA block showed minimal bone formation, the n-HA block was maintained within the defect with its original hexahedral shape. In addition, only a limited inflammatory reaction was observed at sites that received an n-HA block, which might have been due to the high stability of the customized block bone. Conclusions: In the limitation of this study, customized n-HA block could provide a space for periodontal tissue engineering, with minimal inflammation.

Noncontact Fatigue Crack Evaluation Using Thermoelastic Images

  • Kim, Ji-Min;An, Yun-Kyu;Sohn, Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.6
    • /
    • pp.686-695
    • /
    • 2012
  • This paper proposes a noncontact thermography technique for fatigue crack evaluation under a cyclic tensile loading. The proposed technique identifies and localizes an invisible fatigue crack without scanning, thus making it possible to instantaneously evaluate an incipient fatigue crack. Based on a thermoelastic theory, a new fatigue crack evaluation algorithm is proposed for the fatigue crack-tip localization. The performance of the proposed algorithm is experimentally validated. To achieve this, the cyclic tensile loading is applied to a dog-bone shape aluminum specimen using a universal testing machine, and the corresponding thermal responses induced by thermoelastic effects are captured by an infrared camera. The test results confirm that the fatigue crack is well identified and localized by comparing with its microscopic images.

A New Model for Predicting Width Spread in a Roughing Mill - Part II: Application to Flat Rolling (조압연 공정의 판 폭 퍼짐 예측 모델 - Part II : 평판에의 적용)

  • Lee, D.H.;Lee, K.B.;Hwang, S.M.
    • Transactions of Materials Processing
    • /
    • v.23 no.3
    • /
    • pp.145-150
    • /
    • 2014
  • Precision control of the slab is crucial for product quality and production economy in hot strip mills. The current study presents a new model for predicting width spread of a slab with a rectangular cross section during roughing. The model is developed on the basis of the extremum principle for a rigid plastic material and a three dimensional admissible velocity field. This model incorporates the effect of process variables such as the shape factor and the ratio of width to thickness. We compare the results of this model to 3-D finite element (FE) process simulations and also to results from a previous study.

An investigation of non-uniform metal flow during rectangular battery case using impact extrusion process (충격압출 공정을 이용한 직사각형 배터리 케이스 성형 시 불균일 금속 유동 발생 원인 고찰)

  • Lim, Jae-Hyuk;Kim, Yong-bae;Lee, Jong-sup
    • Design & Manufacturing
    • /
    • v.10 no.2
    • /
    • pp.24-28
    • /
    • 2016
  • In this study, relevant to impact extrusion process of the rectangular batter case for electric vehicles, numerical and experimental analyses were conducted to reduce the earring defects induced in the unevenness of metal flow. Since the earring is caused by the non-uniform metal flow induced in the friction and aspect ratio in the bottom section. As a way to reduce the earring, variable land die concept was applied. In order to analyze numerically the complex metal flow by using commercial finite element package, DEFORM 3D, impact extrusion process was simplified in upsetting mode at bottom section and extrusion mode at land section. The impact extrusion experiments were conducted to verify the assessment of process parameter for impact extrusion. As results, variable land die which has longer longitudinal section makes reduce earring defects. In addition, it was confirmed that the effect that slug shape like dog-bone also can reduce the earring. This study is expected to be able to present the useful design guidelines for manufacturing the battery case.

Single-Plane Fluoroscopic Three-Dimensional Kinematics of Normal Stifle Joint in Beagle Dogs

  • Kim, Hyungkyoo;Jeong, Jaemin;Seo, Jeonhee;Lee, Young-Won;Choi, Ho-Jung;Park, Jiyoung;Jeong, Seong Mok;Lee, Haebeom
    • Journal of Veterinary Clinics
    • /
    • v.34 no.5
    • /
    • pp.318-324
    • /
    • 2017
  • The objective of this study was to establish kinematic reference ranges for the femorotibial (FT) joint and the patellofemoral (PF) joint in healthy small-breed dogs by measuring 3D kinematics at the walk. Single-plane fluoroscopy was used to image the stifle joints of five healthy beagle dogs while the dogs were walking. 3D bone models of the femur, patella, and tibia were reconstructed by computed tomography scanning of the beagle dogs' hind limbs. The shape-matching technique was used to measure kinematic data from the fluoroscopic images and the 3D bone models. The cranial translation of the tibia during walking was inversely proportional to the FT joint flexion. There were significant correlations between the patellar motion and the tibial motion. The FT joint flexion had a strong correlation with the patellar proximodistal translation and flexion. Additionally, the tibial mediolateral translation had a strong correlation with the patellar shift and tilt. In this study, normal in vivo 3D FT joint and PF joint kinematics were demonstrated, and the average kinematic parameters were determined in walking beagle dogs.