• Title/Summary/Keyword: DoS detection

Search Result 540, Processing Time 0.03 seconds

Piezoelectric nanocomposite sensors assembled using zinc oxide nanoparticles and poly(vinylidene fluoride)

  • Dodds, John S.;Meyers, Frederick N.;Loh, Kenneth J.
    • Smart Structures and Systems
    • /
    • v.12 no.1
    • /
    • pp.55-71
    • /
    • 2013
  • Structural health monitoring (SHM) is vital for detecting the onset of damage and for preventing catastrophic failure of civil infrastructure systems. In particular, piezoelectric transducers have the ability to excite and actively interrogate structures (e.g., using surface waves) while measuring their response for sensing and damage detection. In fact, piezoelectric transducers such as lead zirconate titanate (PZT) and poly(vinylidene fluoride) (PVDF) have been used for various laboratory/field tests and possess significant advantages as compared to visual inspection and vibration-based methods, to name a few. However, PZTs are inherently brittle, and PVDF films do not possess high piezoelectricity, thereby limiting each of these devices to certain specific applications. The objective of this study is to design, characterize, and validate piezoelectric nanocomposites consisting of zinc oxide (ZnO) nanoparticles assembled in a PVDF copolymer matrix for sensing and SHM applications. These films provide greater mechanical flexibility as compared to PZTs, yet possess enhanced piezoelectricity as compared to pristine PVDF copolymers. This study started with spin coating dispersed ZnO- and PVDF-TrFE-based solutions to fabricate the piezoelectric nanocomposites. The concentration of ZnO nanoparticles was varied from 0 to 20 wt.% (in 5 % increments) to determine their influence on bulk film piezoelectricity. Second, their electric polarization responses were obtained for quantifying thin film remnant polarization, which is directly correlated to piezoelectricity. Based on these results, the films were poled (at 50 $MV-m^{-1}$) to permanently align their electrical domains and to enhance their bulk film piezoelectricity. Then, a series of hammer impact tests were conducted, and the voltage generated by poled ZnO-based thin films was compared to commercially poled PVDF copolymer thin films. The hammer impact tests showed comparable results between the prototype and commercial samples, and increasing ZnO content provided enhanced piezoelectric performance. Lastly, the films were further validated for sensing using different energy levels of hammer impact, different distances between the impact locations and the film electrodes, and cantilever free vibration testing for dynamic strain sensing.

Residue Patterns of Active Ingredients Derived from Melia Azedarach, Nerium Ndicum, and Coptis Chinensis in Rice Using LC-MS/MS (LC-MS/MS를 이용한 멀구슬, 협죽도, 황련 유래 활성성분의 벼 중 잔류양상 연구)

  • Park, Joon-Seong;Nam, Hyo-Song;Kim, Yong-Hwan;Kim, Do-ik;Kim, Sun-Am
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.2
    • /
    • pp.128-133
    • /
    • 2015
  • BACKGROUND: Plant extracts have been used as environment friendly agricultural materials for organic farming in South Korea. However safety evaluation on the plant extracts was not properly tested. The aim of this study was to evaluate safety of the extracts from Melia azedarach, Nerium indicum and Coptis chinensis on cultivating rice. METHODS AND RESULTS: Pant extarcts 300-fold diluted were treated on rice, and residues of M. azedarach, N. indicum and C. chinensis were determined. The analytes from the rice samples were detected by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). The method was validated, and good linearities ($r^2=0.995-0.998$), specificity, and recoveries were obtained. Limits of detection were 0.01 mg/kg for all of the target compounds. Recoveries were 79.3-118.3% at 0.1 mg/kg and 75.2-111.5% at 0.5 mg/kg. The residue levels were below 0.030 mg/kg for azadirachtin, 0.320 mg/kg for oleandrin and 1.460 mg/kg for berberine. CONCLUSION(S): The extracts of M. azedarach, N. indicum and C. chinensis contained azadirachtin, oleandrin and berberine as an active ingredient, respectively. The residue of three active ingredients dramatically decreased after treatment in all fruits, stems and roots of rice.

Development of Quality Analysis Method and System for SOFC (SOFC용 셀의 품질관리 기법개발)

  • Lee, InSung;Park, YoungMin;Kim, DoHyeong;Jun, JoongHwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.81.1-81.1
    • /
    • 2010
  • SOFC 발전시스템의 상용화를 위해 선행되어야 할 것은 스택의 안정적 출력 및 신뢰성 확보이다. 이를 이루기 위해서는 스택을 구성하는 구성요소의 신뢰성 있는 규격 및 검수가 필요하다. 즉, 셀, 밀봉재, 분리판 및 집전체로 대변되는 구성요소들이 스택에 장착되었을 때 그 기능을 최대한 발휘하면서도 점진적 또는 급격한 품질저하가 발생되지 말아야 한다. 특히, 셀의 경우 스택의 성능에 직접적인 영향을 미치는 구성요소로서 품질에 대한 명확한 검수기준이 필요하다. SOFC용 셀은 다공성 anode, 치밀한 전해질, 그리고 다공성 cathode로 구성된 세라믹 소결체이다. 이 때 치밀한 전해질에 결함이 내재되어 있거나 물리적 힘에 의해 신규로 발생할 경우, 연료로 사용되는 수소와 공기가 만나는 cross-over가 발생하게 된다. Cross-over는 연료가 소모되는 문제도 있지만 발열로 인한 Hot spot을 형성시켜서 주변과의 온도구배를 유발하고, 이로 인해 고체 전해질의 균열전파를 일으킬 수 있고 나아가 급격한 셀의 파괴를 야기할 수 있다. 본 연구에서는 SOFC에 사용되는 셀의 형상측정, 물리적 강도 및 결함 검출을 위한 검수기법을 개발하여 스택의 신뢰성 향상과 향후 규격표준화를 위한 기반을 제공하고자, 평판형 셀의 3차원 형상을 정밀하게 측정하는 장치와 일정 면압을 인가하여 특정 형상을 갖고 있는 셀의 물리적 파괴여부를 판단할 수 있는 장치, 그리고 셀의 전해질에 내재된 결함을 검출할 수 있는 장치를 제작하였다. 본 장치들은 $1,000cm^2$급 평판형 셀까지 검수할 수 있도록 고안하여 양산시스템에 접목시킬 수 있도록 고안된 것이다. 본 장치들을 이용한 검수결과, 현재 $700cm^2$급 평판형 셀의 경우 최대 camber가 4mm 이하, 전해질의 He leak rate는 $5{\times}10^{-5}mbar.l/s.cm^2$ 이하라는 검수규격을 본 연구소에서 운전하는 스택에 1차적으로 적용하였으며 현재 검수규격의 신뢰성 및 강화를 위한 연구를 수행 중에 있다.

  • PDF

Drone Detection with Chirp-Pulse Radar Based on Target Fluctuation Models

  • Kim, Byung-Kwan;Park, Junhyeong;Park, Seong-Jin;Kim, Tae-Wan;Jung, Dae-Hwan;Kim, Do-Hoon;Kim, Taihyung;Park, Seong-Ook
    • ETRI Journal
    • /
    • v.40 no.2
    • /
    • pp.188-196
    • /
    • 2018
  • This paper presents a pulse radar system to detect drones based on a target fluctuation model, specifically the Swerling target model. Because drones are small atypical objects and are mainly composed of non-conducting materials, their radar cross-section value is low and fluctuating. Therefore, determining the target fluctuation model and applying a proper integration method are important. The proposed system is herein experimentally verified and the results are discussed. A prototype design of the pulse radar system is based on radar equations. It adopts three different pulse modes and a coherent pulse integration to ensure a high signal-to-noise ratio. Outdoor measurements are performed with a prototype radar system to detect Doppler frequencies from both the drone frame and blades. The results indicate that the drone frame and blades are detected within an instrumental maximum range. Additionally, the results show that the drone's frame and blades are close to the Swerling 3 and 4 target models, respectively. By the analysis of the Swerling target models, proper integration methods for detecting drones are verified and can thus contribute to increasing in detectability.

Comparison of recognition rate with distance on stereo face images base PCA (PCA기반의 스테레오 얼굴영상에서 거리에 따른 인식률 비교)

  • Park Chang-Han;Namkung Jae-Chan
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.1
    • /
    • pp.9-16
    • /
    • 2005
  • In this paper, we compare face recognition rate by distance change using Principal Component Analysis algorithm being input left and right image in stereo image. Change to YCbCr color space from RGB color space in proposed method and face region does detection. Also, after acquire distance using stereo image extracted face image's extension and reduce do extract robust face region, experimented recognition rate by using PCA algorithm. Could get face recognition rate of 98.61%(30cm), 98.91%(50cm), 99.05%(100cm), 99.90%(120cm), 97.31%(150cm) and 96.71%(200cm) by average recognition result of acquired face image. Therefore, method that is proposed through an experiment showed that can get high recognition rate if apply scale up or reduction according to distance.

TFT-LCD Defect Detection Using Mean Difference Between Local Regions Based on Multi-scale Image Reconstruction (로컬 영역 간 평균 화소값 차를 이용한 멀티스케일 기반의 TFT-LCD 결함 검출)

  • Jung, Chang-Do;Lee, Seung-Min;Yun, Byoung-Ju;Lee, Joon-Jae;Choi, Il;Park, Kil-Houm
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.4
    • /
    • pp.439-448
    • /
    • 2012
  • TFT-LCD panel images have non-uniform brightness, noise signal and defect signal. It is hard to divide defect signal because of non-uniform brightness and noise signal, so various divide methods have being developed. In this paper, we suggest method to divide defective regions on TFT-LCD panel image by estimating a menas of two different size of windows, which is suggested by Eikvil et al., and using difference of them. But in this method, the size of detectable defects is restricted by the size of window, hence it has inefficient problem that the size of window have to increase to divide a large defect region. To solve this problem we suggest an algorithm which can divide various size of defects, by using Multi-scale and restrict a detectable size of defects in each scale. To prove an efficiency of suggested algorithm, we show that resulting images of real TFT-LCD panel images and an artificial image with various defects.

Cryptanalysis of Remote User Authentication Scheme (원격 사용자 인증 구조의 암호학적 분석)

  • Choi, Jong-Seok;Shin, Seung-Soo;Han, Kun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.2
    • /
    • pp.327-333
    • /
    • 2009
  • In 2004, Das et al. proposed a scheme for preserving a user anonymity. However, In 2005, Chien and Chen pointed out that Das et al. scheme fail to protect the user anonymity, and proposed a new scheme. And then in 2007, Hu et al. pointed out that Chien and Chen scheme also has some problems; it is Strong masquerading server/user attack, Restricted replay attack, Denial of service attack. it also slow wrong password detection, and proposed a new scheme. In 2008, Bindu et al. repeatedly pointed out on Chien and Chen scheme and proposed their scheme. However, we point out that all of their scheme also has some problems; it is not to protect the user anonymity and Denial of service attack. In addition, Bindu et al. is vulnerable to Strong masquerading server/user attack. Therefore, we demonstrate that their scheme also have some problems; it is the user anonymity and denial of service attack as above.

The Knowledge and Practice of the Breast Self-examination in Women who got health check up (건강 진단 수검 여성들의 유방 자가 검진에 대한 인식도 및 실천정도에 관한 연구)

  • Jeong, Soo-Jin;Choi, Soon-Seok;Park, Jun-Han;Urm, Sang-Hwa;Jeong, Kui-Won;Lee, Chae-Un;Bae, Ki-Taek
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.4 s.63
    • /
    • pp.740-750
    • /
    • 1998
  • The methods for the early diagnosis of breast cancer are mammography, physical examination, breast self-examination(BSE). This study was conducted to investigate the knowledge and practice of BSE by structured questionnaire which included questions on general characteristics, performance of mammography, physical examination of breast, knowledge and practice of BSE. The subjects in this study were 412 females between 20 and 69 year old who visit to the Health Care Center of College of medicine of Inje University from December 1997 to February 1998. The results were as follows. 1. Women who have Soften the regular mammography are 8.19% of these subjects and women who have gotten the regular physical examination by doctors are 4.19% of these subjects. 2. Regarding BSE, 77.4% of these subjects said that they knew BSE and 3.88% of these subjects said that they practiced BSE regularly. It was that women who knew BSE were more younger, better-educated and higher economic status(p=0.001) and lived a normal life with he. husband(p=0.033). And women who practiced BSE regularly were more younger, and married(p=0.001). 3. The most common barrier to doing BSE is 'Do not see the needs/worry unnecessarily', and the most common reasons for doing BSE is 'Early detection of Breast cancer'. 4. The overall frequency and percentage distribution of recommended BSE step in Korea is lower than U.S.A.

  • PDF

Estimation of Blood Pressure Diagnostic Methods by using the Four Elements Blood Pressure Model Simulating Aortic Wave Reflection (대동맥 반사파를 재현한 4 element 대동맥 혈압 모델을 이용한 혈압 기반 진단 기술의 평가)

  • Choi, Seong Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.183-190
    • /
    • 2015
  • Invasive blood pressure (IBP) is measured for the patient's real time arterial pressure (ABP) to monitor the critical abrupt disorders of the cardiovascular system. It can be used for the estimation of cardiac output and the opening and closing time detection of the aortic valve. Although the unexplained inflections on ABP make it difficult to find the mathematical relations with other cardiovascular parameters, the estimations based on ABP for other data have been accepted as useful methods as they had been verified with the statistical results among vast patient data. Previous windkessel models were composed with systemic resistance and vascular compliance and they were successful at explaining the average systolic and diastolic values of ABP simply. Although it is well-known that the blood pressure reflection from peripheral arteries causes complex inflection on ABP, previous models do not contain any elements of the reflections because of the complexity of peripheral arteries' shapes. In this study, to simulate a reflection wave of blood pressure, a new mathematical model was designed with four elements that were the impedance of aorta, the compliance of aortic arch, the peripheral resistance, and the compliance of peripheral arteries. The parameters of the new model were adjusted to have three types of arterial blood pressure waveform that were measured from a patient. It was used to find the relations between the inflections and other cardiovascular parameters such as the opening-closing time of aortic valve and the cardiac output. It showed that the blood pressure reflection can bring wide range errors to the closing time of aortic valve and cardiac output with the conventional estimation based on ABP and that the changes of one-stroke volumes can be easily detected with previous estimation while the changes of heart rate can bring some error caused by unexpected reflections.

The Concentrations of Sulfur Compounds and Sensation of Odor in the Residential Area Around Banwol-Sihwa Industrial Complex (반월.시화공단 주변 주거지역의 악취현황 및 황화합물의 체감도)

  • Kim, Jong-Bo;Jeong, Sang-Jin;Song, Il-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.2
    • /
    • pp.147-157
    • /
    • 2007
  • This study was carried out to investigate the characteristics of fourteen odor compounds from a total of 10 sampling sites in residential areas around Banwol-Sihwa industrial complex. The measurement data are analyzed and compared with sensation of odor unit. Only a hydrogen sulfide out of four sulfur compounds was quantified above the detection limit (0.06 ppb) in the residential area around Banwol industrial complex with leather companies and a sewage treatment plant. The concentrations of VOCs were higher than those measured from a big city, and styrene showed the relatively high concentration from all sampling sites ($2.1{\sim}37.8\;ppb$). In the case of carbonyl compounds, acetaldehyde was found most frequently with the mean of 3.97 ppb, and its concentration difference was not significant between Banwol and Sihwa industrial complex. Of the nitrogen compounds, ammonia was measured at the relatively high concentration from all the sampling sites ($12{\sim}707\;ppb$), and a trimethylamine was found at the odor threshold level (0.1 ppb). The concentrations of styrene and ammonia showed relatively seasonal variation, the concentration of styrene in summer was five times higher than that in autumn, the concentration of ammonia in autumn was two times higher than that in summer. However other odorous compounds did not show such strong seasonal variation. Odor-concentration relationship between odor unit and $H_{2}S$ concentrations from industrial sources was examined and used as odor sensation evaluation, and thus the neighbourhood odor complaints maybe caused during the four seasons from the results.