• Title/Summary/Keyword: Dixon technique

Search Result 14, Processing Time 0.023 seconds

Evaluation of Usefulness of an m-DIXON Technique during an Abdomen MRI Examination : A Comparison with an e-THRIVE Technique (복부 MRI검사에서 m-DIXON기법의 유용성 평가: e-THRIVE기법과 비교 분석)

  • Lee, Bo-Woo;Park, Myung-Cheol;Lee, Jin-Hoi;Kim, Ki-Jin;Bae, Seok-Hwan
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.385-390
    • /
    • 2014
  • This research is conducted to identify whether an m-DIXON technique which is useful for an abdomen MRI examination compared with an existing e-THRIVE technique is a clinically useful or not. There was evaluated quantitative and qualitative to 84 subjects who had abdomen MRI exam due to their liver disease were conducted during a period from September in 2013 to February in 2014. First of all the quantitative evaluation, the m-DIXON technique's SNR was $90.42{\pm}16.90$ and the e-THRIVE technique was $60.42{\pm}11.54$ and the m-DIXON technique's CNR was $52.38{\pm}22.58$ and the e-THRIVE technique was $46.31{\pm}20.25$. Secondly in the qualitative evaluation, the m-DIXON technique's image quality was $4.06{\pm}0.34$, a artifact was $3.64{\pm}0.22$, and fat suppression was $4.16{\pm}0.15$, the e-THRIVE technique's image quality was $3.14{\pm}0.35$, a artifact was $3.06{\pm}0.38$, fat suppression was $3.14{\pm}0.30$. In conclusion, m-DIXON technique for abdomen MRI examination showed superiority over both SNR as a quantitative anaylsis, CNR and a qualitative analysis.

Effect of Gd-EOB-DTPA on Hepatic Fat Quantification using Two-point Dixon Technique (Two-point Dixon기법을 이용한 간의 지방정량화에 Gd-EOB-DTPA가 미치는 영향)

  • Koo, No-Hyun;Choi, Kwan-Woo;Yoo, Beong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.7
    • /
    • pp.215-221
    • /
    • 2017
  • The purpose of present study was to assess whether Gd-EOB-DTPA with gadolinium-based contrast agent administration affects fat quantification using the two-point Dixon technique. Between April 2016 and September, 60 patients who underwent hepatic fat quantification using the two-point Dixon technique were divided into two group (normal liver donors=30, abnormal hepatic steatosis=30) and we compared the variability of mean fat fraction before and after administration Gd-EOB-DTPA. As a results, in both group, fat fraction after injection Gd-EOB-DTPA was significantly decreased (normal liver donors -33.8%, hepatic steatosis -47.2%) compared to before injection Gd-EOB-DTPA, suggesting that Gd-EOB-DTPA affects fat quatification using two-point Dixon technique. In conclusion, hepatic fat quantification using the two-point Dixon technique could maintain diagnostic value by acquiring images before administration Gd-EOB-DTPA.

Assessment of The Accuracy of The MR Abdominal Adipose Tissue Volumetry using 3D Gradient Dual Echo 2-Point DIXON Technique using CT as Reference

  • Kang, Sung-Jin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.603-615
    • /
    • 2016
  • In this study, in order to determine the validity and accuracy of MR imaging of 3D gradient dual echo 2-point DIXON technique for measuring abdominal adipose tissue volume and distribution, the measurements obtained by CT were set as a reference for comparison and their correlations were evaluated. CT and MRI scans were performed on each subject (17 healthy male volunteers who were fully informed about this study) to measure abdominal adipose tissue volume. Two skilled investigators individually observed the images acquired by CT and MRI in an independent environment, and directly separated the total volume using region-based thresholding segmentation method, and based on this, the total adipose tissue volume, subcutaneous adipose tissue volume and visceral adipose tissue volume were respectively measured. The correlation of the adipose tissue volume measurements with respect to the observer was examined using the Spearman test and the inter-observer agreement was evaluated using the intra-class correlation test. The correlation of the adipose tissue volume measurements by CT and MRI imaging methods was examined by simple regression analysis. In addition, using the Bland-Altman plot, the degree of agreement between the two imaging methods was evaluated. All of the statistical analysis results showed highly statistically significant correlation (p<0.05) respectively from the results of each adipose tissue volume measurements. In conclusion, MR abdominal adipose volumetry using the technique of 3D gradient dual echo 2-point DIXON showed a very high level of concordance even when compared with the adipose tissue measuring method using CT as reference.

Skull Base Dermoid Cyst in the Right Infratemporal Fossa Diagnosed Using the Dixon Technique: a Case Report and Review of Literature

  • Kim, Seung Jin;Baek, Hye Jin;Ryu, Kyeong Hwa;Choi, Bo Hwa;Moon, Jin Il;Cho, Soo Buem;Park, Sung Eun;Bae, Kyungsoo;Jeon, Kyung Nyeo;Cho, Eun Bin;An, Hyo Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.2
    • /
    • pp.114-118
    • /
    • 2017
  • Dermoid cysts are benign congenital tumors composed of keratinizing squamous epithelium and dermal derivatives. They account for less than 1% of all intracranial tumors and are rarely exhibited at the base of the skull. To the best of our knowledge, only one case report has presented computed tomography and conventional T1-weighted magnetic resonance (MR) findings that revealed an infratemporal dermoid cyst. In the present study, we report an unusual case of a dermoid cyst in the right infratemporal fossa, which was incidentally detected by MR imaging with the Dixon technique. This article also highlights the importance of meticulous radiological review and the usefulness of the Dixon technique in everyday clinical practice.

Comparison of mDixon, T2 TSE, and T2 SPIR Images in Magnetic Resonance Imaging of Lumbar Sagittal Plane (요추 시상면 자기공명 영상검사에서 mDixon과 T2 TSE, T2 SPIR 영상의 비교 연구)

  • Jung, Da-Bin;Lee, Hae-Kag;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.927-933
    • /
    • 2021
  • The purpose of this study was to compare and analyze the differences in scan time, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the third lumbar vertebral region including the back fat, spinal cord, and cerebrospinal fluid using the mDixon, T2 TSE, and T2 spectral pre-saturation with inversion-recovery (SPIR) techniques. With the factors affecting the SNR fixed, the lumbar sagittal plane images of 30 adults were compared on mDixon, T2 TSE, and T2 SPIR imaging tests. The test times for mDixon, T2 TSE, and T2 SPIR were 115 seconds, 60 seconds, and 60 seconds, respectively. The mDixon T2 images showed higher SNR than the T2 TSE images at the third lumbar vertebral region (p<0.05), lower SNR in the back fat and cerebrospinal fluid (p<0.05) areas, and comparable SNR in the spinal cord (p>0.05). The CNR between the third lumbar vertebral area and back fat was higher in the mDixon T2 images, and the CNR of the cerebrospinal fluid and spinal cord images was higher in the T2 TSE images (p<0.05). The mDixon T2 FS images CNR was lower for the 3rd lumbar vertebral body region and back fat than the T2 SPIR images, and higher for the spinal cord and cerebrospinal fluid images (p<0.05). The CNR between the third lumbar body and back fat areas was higher in the mDixon T2 FS images (p<0.05), and there was no difference in the CNR in the images of the cerebrospinal fluid and the spinal cord (p>0.05). It is difficult to determine whether the mDixon technique is superior to the conventional T2 TSE and T2 SPIR techniques in terms of test time, SNR, and CNR. This study was confined to patients with simple lower back pain and was limited by controlled experimental conditions. Studies using clinically applied protocols are warranted in the future.

ALTERNATIVE DERIVATIONS OF CERTAIN SUMMATION FORMULAS CONTIGUOUS TO DIXON'S SUMMATION THEOREM FOR A HYPERGEOMETRIC $_3F_2$ SERIES

  • Choi, June-Sang;Rathie Arjun K.;Malani Shaloo;Mathur Rachana
    • The Pure and Applied Mathematics
    • /
    • v.13 no.4 s.34
    • /
    • pp.255-259
    • /
    • 2006
  • In 1994, Lavoie et al. have obtained twenty tree interesting results closely related to the classical Dixon's theorem on the sum of a $_3F_2$ by making a systematic use of some known relations among contiguous functions. We aim at showing that these results can be derived by using the same technique developed by Bailey with the help of Gauss's summation theorem and generalized Kummer's theorem obtained by Lavoie et al..

  • PDF

Correlation Analysis between Fat Fraction and Bone Mineral Density Using the DIXON Method for Fat Dominant Tissue in Knee Joint MRI: A Preliminary Study (지방우세 딕슨기법을 이용한 슬관절 자기공명영상 지방신호분율과 골밀도 간의 상관관계 분석: 예비 연구)

  • Sung Hyun An;Kyu-Sung Kwack;Sunghoon Park;Jae Sung Yun;Bumhee Park;Ji Su Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.427-440
    • /
    • 2023
  • Purpose This study aimed to investigate the correlation between the fat signal fraction (FF) of the fat-dominant bone tissue of the knee joint, measured using the MRI Dixon method (DIXON) technique, and bone mineral density (BMD). Materials and Methods Among the patients who underwent knee DIXON imaging at our institute, we retrospectively analyzed 93 patients who also underwent dual energy X-ray absorptiometry within 1 year. The FFs of the distal femur metaphyseal (Fm) and proximal tibia metaphyseal (Tm) were calculated from the DIXON images, and the correlation between FF and BMD was analyzed. Patients were grouped based on BMD of lumbar spine (L), femoral neck (FN), and common femur (FT) respectively, and the Kruskal-Wallis H test was performed for FF. Results We identified a significant negative correlation between TmFF and FN-BMD in the entire patient group (r = -0.26, p < 0.05). In female patients, TmFF showed a negative correlation with FN-BMD, FT-BMD, and L-BMD (r = -0.38, 0.28 and -0.27, p < 0.05). In male patients, FmFF was negatively correlated with only FN-BMD and FT-BMD (r = -0.58 and -0.42, p < 0.05). There was a significant difference in the TmFF between female patients grouped by BMD (p < 0.05). In male patients, there was a significant difference in FmFF (p < 0.05). Conclusion Overall, we found that FF and BMD around the knee joints showed a negative correlation. This suggests the potential of FF measurement using DIXON for BMD screening.

Chemical Shift Artifact Correction in MREIT

  • Minhas, Atul S.;Kim, Young-Tae;Jeong, Woo-Chul;Kim, Hyung-Joong;Lee, Soo-Yeol;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.461-468
    • /
    • 2009
  • Magnetic resonance electrical impedance tomography (MREIT) enables us to perform high-resolution conductivity imaging of an electrically conducting object. Injecting low-frequency current through a pair of surface electrodes, we measure an induced magnetic flux density using an MRI scanner and this requires a sophisticated MR phase imaging method. Applying a conductivity image reconstruction algorithm to measured magnetic flux density data subject to multiple injection currents, we can produce multi-slice cross-sectional conductivity images. When there exists a local region of fat, the well-known chemical shift phenomenon produces misalignments of pixels in MR images. This may result in artifacts in magnetic flux density image and consequently in conductivity image. In this paper, we investigate chemical shift artifact correction in MREIT based on the well-known three-point Dixon technique. The major difference is in the fact that we must focus on the phase image in MREIT. Using three Dixon data sets, we explain how to calculate a magnetic flux density image without chemical shift artifact. We test the correction method through imaging experiments of a cheese phantom and postmortem canine head. Experimental results clearly show that the method effectively eliminates artifacts related with the chemical shift phenomenon in a reconstructed conductivity image.

Malicious Users Detection and Nullifying their Effects on Cooperative Spectrum Sensing

  • Prasain, Prakash;Choi, Dong-You
    • Journal of Information Technology Services
    • /
    • v.15 no.1
    • /
    • pp.167-178
    • /
    • 2016
  • Spectrum sensing in cognitive radio (CR) has a great role in order to utilize idle spectrum opportunistically, since it is responsible for making available dynamic spectrum access efficiently. In this research area, collaboration among multiple cognitive radio users has been proposed for the betterment of detection reliability. Even though cooperation among them improves the spectrum sensing performance, some falsely reporting malicious users may degrade the performance rigorously. In this article, we have studied the detection and nullifying the harmful effects of such malicious users by applying some well known outlier detection methods based on Grubb's test, Boxplot method and Dixon's test in cooperative spectrum sensing. Initially, the performance of each technique is compared and found that Boxplot method outperforms both Grubb's and Dixon's test for the case where multiple malicious users are present. Secondly, a new algorithm based on reputation and weight is developed to identify malicious users and cancel out their negative impact in final decision making. Simulation results demonstrate that the proposed scheme effectively identifies the malicious users and suppress their harmful effects at the fusion center to decide whether the spectrum is idle.

CHEMICAL SHIFT IMAGING

  • Yi, Yun;Kim, Min-Gi
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.22-25
    • /
    • 1992
  • Lipid component and water component image in living organism can be acquired due to its chemical shift difference. Various techniques for chemical shift imaging were used for acquiring separated image. It is necessary two imaging experiments to acquire two separated images wi th Dixon's method. This technique is less susceptible to local magnetic inhomogeneities and easily applied to multi-slice imaging. With CHESS and SECSI method, which based on chemical selectivity of R.F pusle, either water or lipid image can be acquired by one imaging experiment. However, those are more susceptible to local magnetic field inhomogeneities and difficult to apply to multi-slice imaging. The SECSI method showed best signal suppression ratio of fat and water, which is measure of separation of water and fat.

  • PDF