• 제목/요약/키워드: Distribution lines

검색결과 1,026건 처리시간 0.037초

비대칭 3상 선로에서 변압기의 철심구조별 문제점 분석 및 방지대책 (Problem Analysis by Iron Core Structure of the Transformer on Asymmetric three Phase lines and Prevention Measures)

  • 신동열;윤동현;차한주
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1536-1541
    • /
    • 2012
  • The study analyzed problems by iron core structure of the three phased transformer on asymmetric three phase lines, which included line disconnections, ground faults, COS OFF, and unbalanced loads on the power distribution system. In particular, by analyzing PT combustion cases within the MOF, the study was able to analyze the combustion cause of the core-type transformer and its effect on the system, conduct simulations and practice demonstrations on the characteristics for each iron core structure of the three phase transformer using PSCAD/EMTDC, and suggest measures to prevent the combustion of the core-type transformer.

와전류 기법을 이용한 가공전력선 열화 진단 (Degradation Diagnosis of Overhead Power Lines Using Eddy Current Technology)

  • 김충혁;김탁용;오용철;최운식;조춘남
    • 한국전기전자재료학회논문지
    • /
    • 제27권5호
    • /
    • pp.322-327
    • /
    • 2014
  • Internal corrosion of the distribution line can be detected in order to develop techniques of non-destructive inspection methods that operate only on the metal track eddy current diagnosis is possible by applying the technique investigated. Sensor for the production of a finite element method modeled by using an eddy current sensor, a distribution line by using an accelerated aging samples of sodium hydroxide was prepared. Sheathed cables for internal corrosion studies detected using an eddy current sensor is considered to be possible.

고압 배전선로를 이용한 고속 전력선 통신 가입자망 구축 연구 (Field Trial of Power Line Communication Access Network over Medium Voltage Power Distribution Grid)

  • 이재조;오휘명;박영진;김관호;이대영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.3040-3042
    • /
    • 2005
  • During the last several years, interest in broad-band power line communications (PLC) has been grown over medium voltage(MV) power distribution lines as well as low voltage lines. This paper introduces a medium voltage PLC test field that is set up in the suburbs of Euiwang city in Korea. This test field could be used not only for the measurement of communication channel environment but also for internet service. This paper shows the configuration of medium voltage test field with network devices like MV signal coupler and the results of channel environment like noise and impulse response. It also shows the service performance of PLC access network through network management system.

  • PDF

옥내배선의 전자계계산 및 감소대책 (Calculation and Mitigation of Elotromagnetic Fields for Indoor Distribution Lines)

  • 강대하;조용호;이영식;박상호;김휘칠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1572_1573
    • /
    • 2009
  • In this study electromagnetic fields generated by currents of electric wires with finite lengths were deduced and formulated to apply to the indoor distribution lines and also using the formula electromagnetic fields were calculated for various configurations of conductors and through analyzing the results mitigation of electromagnetic fields was investigated.

  • PDF

ABC 배전 접속 시스템에 대한 연구 (The Research into Connecting System for Aerial Bundled Cable in Distribution Line)

  • 이용순;최경선;주종민;이철호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.495-498
    • /
    • 2001
  • The distribution line through which electricity is supplied from substation to customer generally varies by underground line and overhead line. In contrast that the underground line is shielded, the overhead lines do not have the shield layer. To overcome this weak point of the overhead lines, the aerial bundled cable(ABC) connection systems have been developed. The basic concept of the ABC connection system is the application of the underground cable system containing complete shield layer to the overhead cable system. The ABC system is the innovative technologies which enable the prevention of electric shocks, reduction of the maintenance charge and damage of the cable. This paper give a full detail of vertical connection system applied within a country.

  • PDF

지중 배편케이블의 열화에 미치는 온수의 영향 (Effects of Hot Water on the Aging of URD Power Cables)

  • 한재홍;송일근;김주용;이병성;정종욱
    • 한국전기전자재료학회논문지
    • /
    • 제15권7호
    • /
    • pp.609-614
    • /
    • 2002
  • In this study, we investigated the effects of hot water on the aging of URD power cables due to the hot water ingress to power distribution lines. Hot water contacted and non-contacted cables extracted from 2 distribution lines were characterized by the measurement of oxidation induction time(OIT) and chemical structure. In OIT measurement, hot water contacted cables showed the shorter OIT than non-contacted ones. Especially, hot water contacted insulation layer near insulation shield showed the shortest OIT. In chemical structure analysis, the antioxidant content was decreased and the acid concentration was increased by hot water ingress. From this results, it can be concluded that the hot water ingress to power cable may be accelerate the aging by means of antioxidant consumption.

Neurofuzzy Estimation for Fault Location Based on PLC

  • Tipsuwanporn, V.;Rukkaphan, S.;Kongratana, V.;Numsomran, A.;Tuppadung, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.157.5-157
    • /
    • 2001
  • Generally, the application of Programmable Logic Controller PLC is emphasized on the Process Control. This paper presents Neurofuzzy application, Which can estimate the distance to a fault by means of PLC and based up on the Electrical Power System theory and ground resistance. The case study refers to the distribution lines of the Provincial Electricity Authority (PEA). Also, the thesis is supposed to be of much benefit: saving time both to go to the scene and to clear fault, reducing unpleasant impacts on customers and stabilizing reliability of the distribution lines.

  • PDF

Spitzer IRS mapping of L1251B

  • 이정은
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.58.2-58.2
    • /
    • 2010
  • L1251B, which was revealed as a small group of protostars by the Spitzer Space Telescope (SST), presents a great site of studying chemical evolution in gas and ice as well as various dynamical processes associated with star formation (infall, rotation, and outflow). We have mapped L1251B with the Infrared Spectrograph (IRS) aboard the SST to study the chemical distribution in the phases of gas and ice and the dynamical feature related to shock in the region. Various atomic lines and the $H_2$ pure rotational lines, which trace different shock velocities, were detected. In addition, the distribution of the water and $CO_2$ ices hints variety of the ice desorption mechanism in L1251B.

  • PDF

가공배전선로의 뇌단선 현상과 내뢰설비의 뇌써어지 전압 저감효과에 관한 연구 (A Study on the Reduction Effects for Surge Voltage of Lightning protective Equipments and the Arc Fusion Mechanisms in the Distribution lines)

  • 남궁도;김상준;이병성;정동학;이용한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.167-170
    • /
    • 1997
  • The arc fusion faults in the distribution lines are occurred by lightning surge, stress corrosion and substance touching. Arc fusion fault by lightning surge is one of the most frequent occurrence. In this report, we studied the mechanisms of the Arc fusion faults. Also, we analyzed the reduction effects for surge voltage of lightning protective equipments.

  • PDF

배전급 고분자 현수애자의 제조기술 개발 (Manufacturing Technique of Suspension Insulator far Distribution Lines Using Composite materials)

  • 홍진영;김영성;지응서;김영찬;백주흠;김동욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.306-310
    • /
    • 1996
  • In this paper a series of developing process for an insulator which can be employed in overhead distribution lines, using polymeric composite materials, is introduced. In order to design an insulator for heavily polluted area, weathershed of alternating type was adopted, which could have longer leakage distance. Modified EVA was used as surface material which has good electrical and mechanical characteristics as well as superior chemical stability. FRP core was covered with above surface material through heat shrinking process. By standardization of each process, higher productivity and lower production cost could be ensured. The developed insulator has been put under various tests including long-term field test and artificial aging test and satisfactory results were obtained.

  • PDF