• Title/Summary/Keyword: Distribution lines

Search Result 1,026, Processing Time 0.033 seconds

Development of overhead distribution line diagnosis system program (가공 배전선로 진단시스템 프로그램 개발)

  • Dong Hyun Chung;Deok Jin Lee
    • Smart Media Journal
    • /
    • v.12 no.5
    • /
    • pp.81-87
    • /
    • 2023
  • In this paper, accidents in high-voltage overhead distribution lines, which provide stable power supply in the power system, cause inconvenience in life and disruption of production of companies. 22.9 [kV] high-voltage overhead power distribution lines aim to improve reliability and stability, such as damage caused by rain, snow, wind, etc., or electric shock prevention. Therefore, in order to prevent wire disconnection accidents due to deterioration of electrical conductivity or tensile strength due to corrosion of overhead distribution lines, it is necessary to prevent unexpected accidents in the future through regular inspection and repair. In order to diagnose deterioration due to corrosion of distribution lines, a diagnostic system (measuring instrument) is installed on the wires to monitor the condition of the wires. The manager on the ground receives the measured data through ZigBee wireless communication, controls the diagnosis system through the diagnosis system program, and grasps the condition of the overhead distribution line through the measured data and photographed photos, and predicts the life of the wire along with the visual inspection method. developed a program.

Analysis of Normal Induced Voltage on Telecommunication Line according to Earth Resistivity in Distrbution Lines (배전선로에서의 대지 저항율에 따른 통신선 상시 유도전압 분석)

  • Kim, Hyoun-Su;Yeo, Sang-Min;Kim, Chul-Hwan;Lyu, Seung-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.223_224
    • /
    • 2009
  • This paper investigates a normal induced voltage according to earth resistivity from distribution lines using calculation method of the normal induced voltage on telecommunication line. The induced voltage according to earth resistivity from distribution lines is verified by vector analysis and EMTP(Electro-Magnetic Transients Program).

  • PDF

Analysis on the relation between electric current and magnetic field near transmission lines (송전선로에서 전류와 자계의 상관관계 분석)

  • Cho, Sung-Bae;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.3-5
    • /
    • 1997
  • The relation between electric current and magnetic field under three overhead transmission lines being operated was studied. It was examined for a difference each other in comparison with calculated value and measured value for current, magnetic field. With magnetic field equations made out, The magnetic field distribution around transmission lines had made to figure out with easy by load electric current value. Additionally, we are going to describe the distribution curve of magnetic exposure volume for KEPCO's T/L.

  • PDF

Distribution Condition of Electrical and Magnetic Fields under Distribution Line (배전선로하의 전자계 분포 실태)

  • Jang, T.I.;Lee, J.P.;Lee, S.D.;Lee, D.I.;Yoo, Y.P.;Jeong, I.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.470-472
    • /
    • 2003
  • This paper presents the measurement results and the statistical analysis of electrical and magnetic fields in the vicinity of overhead distribution lines. The maximum values of electrical and magnetic fields are 0.042kV/m and 8.3mG. The median values are 0.005kV/m and 1.3mG. The electrical and magnetic fields of distribution lines are compared to those of transmission lines and home appliances.

  • PDF

Technical Feasibility Study on Live-line Maintenance Robot System for Overhead Distribution Lines (가공 배전선로 활선 정비 로봇 시스템의 기술 타당성 검토)

  • Joon-Young, Park;Yoon-Geon, Lee;Young-Sik, Jang
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.49-53
    • /
    • 2022
  • The distribution live-line work method is an operation method of working in a state in which electricity flows through overhead distribution lines to minimize inconvenience to electric customers due to power failure. In June 2016, to strengthen the safety of electrical workers, Korea Electric Power Corporation announced that it would in principle abolish the rubber glove method, in which workers wore protective equipment such as rubber gloves and performed their maintenance work. In addition, KEPCO announced that it would develop a short-range live working method using smart sticks and an advanced live-line maintenance robot system where workers work without touching wires directly. This paper is a preliminary study for the development of the live-line maintenance robot system, and deals with the results of analyzing the technical feasibility of whether the live works performed by workers can be replaced by robots or not.

Theoretical and Experimental Analysis of Extremely Low Frequency Magnetic Field in the Vicinity of the Transformer Station of Overhead Power Lines

  • Ghnimi, Said;Rajhi, Adnen;Gharsallah, Ali;Bizid, Youssef
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1655-1662
    • /
    • 2018
  • This paper studies the magnetic fields between the power lines which are finite length and other ones which are infinitely long around the first tower in the proximity of the power transformers. They will be used as a source of disturbance applied to the power line. The method applied in this study was gradual; develop the theoretical formulation of the magnetic fields of these lines which are finite length and other ones which are infinitely long, examine the effects of different couplings between the different neighboring lines and the distribution transformers on behavior of magnetic fields. The method also focused on the experimental results analyzing the magnetic fields which will be used as a source applied to the auditory implants EMC. The theoretical and experimental results were compared and discussed for three power lines (90kV, 150kV and 225kV) near the power station, and it proved the effect of these substations on the simulated and measured results of the magnetic field. The maximum intensities of magnetic fields measured at the height of 1m from the ground for the circuit of three lines close to each substation were significantly lower than the ICNIRP reference levels for occupational and non occupational exposures.

Long Term Distribution Planning Process using the Forecasting Method of the Land Use (토지용도에 따른 부하예측을 이용한 중장기 배전계획 수립)

  • Kim, Joon-Oh;Park, Chang-Ho;Sun, Sang-Jin;Lee, Jae-Bong;Kwon, Sung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1447-1449
    • /
    • 1999
  • The KEPCO is developing the load forecasting system using land-use simulation method and distribution planning system. A distribution planning needs the data of present loads, forecasted loads and substations. distribution lines information. By the distribution planning system, the distribution line designer determines the substations and feeder lines plan. This paper presents the method of formulation process for the long term load forecasting and optimal distribution planning, and describes the case study of long term distribution planning of Suwon-city according to the newly applied method.

  • PDF

Live Lines Tracing Method in Power Distribution System with 3-phase-4 wires (삼상 다중 접지 배전계통에서 활선로 추적 방법)

  • Zheng, Yan-peng;Byun, Hee-Jung;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.559-562
    • /
    • 2017
  • In city, tracing of power transmission lines is difficult due to compound installation of overhead and underground lines, transposition, bad view caused by trees or big buildings. It is hard problem for electrical technician on site to trace power transformers or power lines to serve customers in 3 phase -4 wires power distribution systems. It is necessary that the correct and fast tracing method is required for load balancing among distribution lines. Old technology use to trace off-lines with high power impulse injection. Our proposed method use to trace live lines with very small power high frequency signal injection. Typical power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the power transformer to serve customers. Two end communication terminals are required to be synchronized between them for determination on electrically same phases. Challenging issue is to achieve synchronization without GPS providing synchronizing time. A novel power transformer and wire identification system is designed and implemented. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts in a big commercial building. Also some simulations are done to help and understand the concepts by using MATLAB Simulink simulator.

  • PDF

Calculation of Magnetic Fields under 3 Phase Power Lines with Branch Lines (분기선로가 있는 3상 전력선로하의 전자파 자계 계산)

  • Kang, Dae-Ho;Lee, Yong-Sik;Kim, Bu-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.110-119
    • /
    • 2009
  • In this study magnetic fields near electric power lines with branch lines which have a arbitrary angle were derived and formulated by dipole antenna theory and could be calculated easily using the formula. It seems that those formula could be applicable to the consideration of magnetic fields during the design of distribution lines with branch lines. As an example those formulated equations on elements of magnetic fields were applied to a model of 3 phase distribution lines with branch lines and calculated by Matlab programs and the results were presented The analyzed results are follows. The resultant magnetic field is dominated by the componant By all over y-axis in the case of the smaller branched angle $\alpha$ and the lower observed point z. In case of ${\alpha}=\frac{\pi}{2}$[rad], the resultant field is affected by the componant Bx. The resultant field is dominated by the componant Bz at the vicinity of the power lines and it shows very large value at the branch line position of y-axis in case of ${\alpha}>\frac{\pi}{2}$.

Kwangiu City Long Term Distribution Planning Process using the Land use Forecasting Method (토지용도에 따른 부하접촉을 이용한 광주시 장단기 최적화 배전계획)

  • Kang, Cheul-Won;Kim, Hyo-Sang;Park, Chang-Ho;Kim, Joon-Oh
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.495-497
    • /
    • 2000
  • The KEPCO is developing the load forecasting sysetm using land use simulation method and distribution planning system. Distribution planning needs the data of presents loads, forecasted loads sub-statin, and distribution lines. Using the data, determine the sub-station and feeder lines according to the load forecasting data. This paper presents the method of formulation processfor the long term load forecasting and optimal distribution planning and optimal distribution planning. And describes the case study of long term distribution planning of Kwangju city accord to the newly applied method.

  • PDF