• Title/Summary/Keyword: Distribution generator

Search Result 545, Processing Time 0.024 seconds

Performance Evaluation of SCR System for Generator Engine on Training Ship KAYA (가야호 발전기용 SCR System의 성능 평가)

  • Jung, Suk-Ho;Jeong, Tae-Young;Hwang, Sung-Chul
    • Journal of Power System Engineering
    • /
    • v.19 no.6
    • /
    • pp.68-74
    • /
    • 2015
  • NOx emission has been controlled because it is a major cause of the acid rain and effects considerably on formation and destruction of ozone. A SCR system on diesel engine is necessary to clear TierIII, because IMO(International Maritime Organization) plans on tightening regulations to TierIII at $1^{st}$ January 2016. In this study, flow analysis was accomplished with ANSYS Fluent program so that the SCR system would be retrofitted in training ship KAYA and the temperature distributions of exhaust gas in SCR sytem were investigated after it was installed. As a result, it was confirmed that pressure and velocity distributions in SCR system were depended on pipe line shapes, then it was designed as the pressure was lower. The temperature differential between 1 and 3 point was $15^{\circ}C$ because of evaporative latent heat of urea and the temperature of 4 point after catalyst was increased by $5^{\circ}C$ than 3 point because of exothermic reaction.

Experiments on the Thermal Stratification in the Branch of NPP

  • Kim Sang Nyung;Hwang Seon Hong;Yoon Ki Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.1206-1215
    • /
    • 2005
  • The thermal stratification phenomena, frequently occurring in the component of nuclear power plant system such as pressurizer surge line, steam generator inlet nozzle, safety injection system (SIS), and chemical and volume control system (CVCS), can cause through-wall cracks, thermal fatigue, unexpected piping displacement and dislocation, and pipe support damage. The phenomenon is one of the unaccounted load in the design stage. However, the load have been found to be serious as nuclear power plant operation experience accumulates. In particular, the thermal stratification by the turbulent penetration or valve leak in the SIS and SCS pipe line can lead these safety systems to failure by the thermal fatigue. Therefore in this study an 1/10 scaledowned experimental rig had been designed and installed. And a series of experimental works had been executed to measure the temperature distribution (thermal stratification) in these systems by the turbulent penetration, valve leak, and heat transfer through valve. The results provide very valuable informations such as turbulent penetration depth, the possibility of thermal stratification by the heat transfer through valve, etc. Also the results are expected to be useful to understand the thermal stratification in these systems, establish the thermal strati­fication criteria and validate the calculation results by CFD Codes such as Fluent, Phenix, CFX.

The Underwater Propagation of the Noise of Ship's Engine (기관소음의 수중전파에 관한 연구)

  • 박중희
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.16 no.2
    • /
    • pp.69-76
    • /
    • 1980
  • This paper describes the measurement of the underwater noises produced by the engine vibration around the engine room of stern trawler MIS Sae-Ba-Da(2275GT, 3,600 PS) and pole kner M/S Kwan-Ak-San (243 GT, 1000 PS) while the ship is stopping. The underwater noise pressure level was measured with the underwater level meter of which measuring range is 100 to 200 dB(re bLPa). A and B denotes the maximum pressure level measured at right beneath the bottom of the engine room, while the main engine of the Sae-Ba-Da revoluted at 750 and 500 rpm, respectively. C denotes that of the main engine of the Kwan-Ak-San revoluted at 350 rpm, and D that of the generator of the Sae-Ba-Da revoluted at 720 rpm. Thus A, B, C and D were set for the standard sound source for the experiment. The results obtained are as follows: 1. The noise Pressure level at A, B, C and D were 170.5,165,153 and 158dB, respectively. 2. When the check points distanted vertically 1, 10, 20, 30, 40, 50m from the sound source, the underwater noise presure levels were 170.5, 155, 148, 144 and 138 dB and the directional angle was 116\ulcorner in case of A. 3. The sound level attenuated at the rate of 20dB per 10" meters of the horizontal distance from the sound sources. 4. The frequency distribution of the noise was 100Hz to 10KHz and predominant frequency was 700 to 800Hzminant frequency was 700 to 800Hz

  • PDF

Analysis of Symmetric and Periodic Open Boundary Problem by Coupling of FEM and Fourier Series

  • Kim, Young Sun
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.130-134
    • /
    • 2013
  • Most electrical machines like motor, generator and transformer are symmetric in terms of magnetic field distribution and mechanical structure. In order to analyze these problems effectively, many coupling techniques have been introduced. This paper deals with a coupling scheme for open boundary problem of symmetric and periodic structure. It couples an analytical solution of Fourier series expansion with the standard finite element method. The analytical solution is derived for the magnetic field in the outside of the boundary, and the finite element method is for the magnetic field in the inside with source current and magnetic materials. The main advantage of the proposed method is that it retains sparsity and symmetry of system matrix like the standard FEM and it can also be easily applied to symmetric and periodic problems. Also, unknowns of finite elements at the boundary are coupled with Fourier series coefficients. The boundary conditions are used to derive a coupled system equation expressed in matrix form. The proposed algorithm is validated using a test model of a bush bar for the power supply. And the each result is compared with analytical solution respectively.

Solid Core Suspension Disc Insulators Preventing Puncture Caused by Steep Front Surge Voltage

  • Sangkasaad, Samruay
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.5
    • /
    • pp.165-170
    • /
    • 2003
  • This paper presents development of solid core suspension disc insulators (cap and cap suspension disc insulator) for replacing cap and pin suspension disc insulators in overhead transmission and distribution lines which expose to lightning discharges. By this means the punctured problem caused by steep front surge voltage created by lightning discharge on the lines can be solved. The solid core suspension insulator was designed and constructed based on the dimensions of conventional suspension disc insulators (cap and pin insulators). The insulators are made of alumina porcelain. The electrical and mechanical characteristics of the solid core suspension insulators were carried out. The puncture test was performed in the air by applying steep front impulse voltage with amplitude about 2.5 per unit of 50% flashover (CFO) of the insulator unit at negative standard lightning impulse $1.2/50\;\mu\textrm{s}$ with steepness up to $9200\;kV/\mu\textrm{s}$. The testing results show that solid core suspension disc insulators are not punctured eventhough the steepness of the steep front impulse voltage was increased up to $9200\;kV/\mu\textrm{s}$.

Numerical Analysis on Cooling Characteristics of Oxidizer-Rich Preburner (산화제 과잉 예연소기 냉각 성능 수치 해석)

  • Lee, Seon-Mi;Ha, Seong-Up;Lee, Soo Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.3
    • /
    • pp.67-75
    • /
    • 2013
  • The numerical analysis for the verification of preburner's cooling characteristics applying to kerosene-LOx rocket engine has been fulfilled. The distribution of combustion gas properties in primary combustion zone was calculated by the mixture ratio based on head injector arrangement, the properties of oxygen flowing in wall channels as coolant were applied under real-gas conditions, and multi-phase mixing model was employed to calculate the mixing process of primary combustion zone with liquid oxygen which was used for wall cooling. The results of numerical analysis were compared with the experimental results, hence thermo-physical properties in cooling channels and a combustor could be quantitatively identified.

A Study for Optimal Design of the AIG to Improve the Performance of DeNOx Facilities Installed in Combined Cycle Plant (복합화력 탈질설비 성능향상을 위한 암모니아 주입 그리드의 최적설계 방안에 관한 연구)

  • Kim, Kwang-Chu;Park, Man-Heung;Yoon, Jun-Kyu;Lim, Jong-Han
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.811-820
    • /
    • 2007
  • A Study on the optimal design of the AIG(Ammonia Injection Grid) to improve the performance of DeNOx facilities in the HRSG(Heat Recovery Steam Generator) was performed using the CFD analysis. On the basis of the flow analysis results in the case that the AIG in the HRSG was not installed, the numerical analyses according to the positions of AIG, injection angles of nozzle and the control of ammonia injection quantity were carried out. The standard deviation according to factors was calculated for quantitative comparison. As the results, the AIG in the HRSG should be installed in the position that the uniform flow field shows through the exact flow analysis in the previous of the AIG design and installation. In the case the AIG has already been installed and non uniform flow distribution shows, it is recommended that flow correction device or KoNOx catalyst should be used. Otherwise, the control of ammonia injection angle or the ammonia injection quantity using the velocity profile analysis is demanded to accomplish the optimal performance.

Experimental Estimation on Magnetic Friction of Superconductor Flywheel Energy Storage System

  • Lee, Jeong-Phil;Han, Sang-Chul;Park, Byeong-Choel
    • Journal of Magnetics
    • /
    • v.16 no.2
    • /
    • pp.124-128
    • /
    • 2011
  • This study estimated experimentally the loss distribution caused by magnetic friction in magnetic parts of a superconductor flywheel energy storage system (SFES) to obtain information for the design of high efficiency SFES. Through the spin down experiment using the manufactured vertical shaft type SFES with a journal type superconductor magnetic bearing (SMB), the coefficients of friction by the SMB, the stator core of permanent magnet synchronous motor/generator (PMSM/G), and the leakage flux of the metal parts were calculated. The coefficients of friction by the stator core of PMSM/G in case of using Si-steel and an amorphous core were calculated. The energy loss by magnetic friction in the stator core of PMSM/G was much larger than that in the other parts. The level of friction loss could be reduced dramatically using an amorphous core. Energy loss by the leakage magnetic field was small. On the other hand, the energy loss could be increased under other conditions according to the type of metal nearby the leakage magnetic fields. In manufactured SFES, the rotational loss by the amorphous core was approximately 2 times the loss of the superconductor and leakage. Moreover, the rotational loss by the Si-steel core is approximately 3~3.5 times the loss of superconductor and leakage.

Importance of the Temporal Variability of Rainfall Statistics in Stochastic Rainfall Modeling (추계강우모형에서의 강우통계의 시간적 변동성 연구)

  • Kim, Dong-Kyun;Lee, Jin-Woo;Cho, Yong-Sik
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.51.2-51.2
    • /
    • 2010
  • A novel approach of Poisson cluster stochastic rainfall generator was validated in its ability to reproduce important rainfall and watershed response characteristics at 104 locations of the United States. The suggested novel approach - The Hybrid Model(THM), as compared to the traditional ones, has an additional function to account for the year-to-year variability of rainfall statistics. The two-sample Kolmogorov-Smirnov test was used to see how well THM and traditional approach of Poisson cluster rainfall model reproduce the distribution of the following hydrologic variables: monthly maximum rainfall depths with 1, 3, 6, 12, and 24 hour duration, monthly maximum flow peaks at the virtual watersheds with Curve Number of 50, 60, 70, 80 and 90; and monthly runoff depths at the same virtual watersheds. In all of the testing variables, THM significantly outperformed the traditional approach. This result indicates that the year-to-year variability of rainfall statistics contains important information about the characteristics of rainfall processes that were not considered by the conventional approach of Poisson cluster rainfall modeling and that further considering it in rainfall simulation will enhance the performance of the rainfall models.

  • PDF

Experimental Verification of Induction Phenomenon on Telecommunication Lines by Applying Its Occurrence Mechanisms Using an Artificial ELF Source Generator

  • Lee, Sang-Mu;Gimm, Yoon-Myoung;Eun, Chang-Soo
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.276-281
    • /
    • 2010
  • In this paper, an electromagnetic induction on a telecommunication line by the distribution line of a power provision system or a feeder line of an electrified railway system has been verified through experiments. The basic cause of induction occurrence by these practical power provision systems is the returning current through the earth. This principle has been confirmed by the experiments documented in this paper which implemented these mechanisms to incur an induction. Experimental methods were used to produce the returning current through the earth. The experiment to find a relationship between inducing strength and the distance between the two phase lines in a power provision line has also been included to confirm that, when the distance is enlarged, the induction effect increases as the cross-nullification effect of magnetic fluxes decreases. An experiment for the existence of a shielding effect by another conduction length material has been addedas a protection measure against the induction.