• 제목/요약/키워드: Distribution generator

검색결과 547건 처리시간 0.029초

무효전력을 고려한 마이크로그리드의 단독운전 판단 알고리즘 (Islanding detection algorithm for microgrid considering reactive power)

  • 강용철;장성일;차선희;이병은;김연희;이지훈;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.236-237
    • /
    • 2006
  • A microgrid is a new type of power system which is formed by the interconnection of small generator to distribution systems. Microgrids are able to supply electric power to their loads independently, which is called with islanding operation, even if they're separated from the power system. As a result, microgrids must be equipped with specific islanding detection schemes for the islanding operation of microgrids. This paper studies an islanding detection method considering reactive power. The proposed method is dealing with the reactive power of the cable which connects between a microgrid and a power system. To show the validity of the proposed method, many islanding operation cases are tested by varying the load conditions of microgrids.

  • PDF

소수력발전의 배전계통 연계를 위한 기술적 분석 (Technical Analysis for Small Hydro-power Generator Integrated with Electric Distribution Systems)

  • 정원욱;김상준;윤기갑;서정출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.529-530
    • /
    • 2006
  • 분산형 전원이 전력계통에 연계됨에 따라 역조류, 보호협조, 계통 동기화, 전기품질 문제 등 여러 가지 문제를 야기한다. 이에 따라 전력회사에서는 분산형 전원의 계통연계 기술 기준을 제시하고 해당 분산형 전원의 계통 연계에 대한 기술 검토를 수행한다. 본 논문에서는 동기발전기형 2500KVA 소수력발전기 2대의 배전계통 연계에 대한 기술적 검토를 수행하였으며 해당 분산형 전인이 동기발전기임을 고려하여 계통연계시 상시전압변동 및 보호방식에 대해 집중 분석하였다. 먼저 소수력발전기가 연계되는 지점에서의 기존 선로 및 전력설비의 여건과 소수력발전기의 출력용량 및 역률을 고려하여 연계 지점에서의 전압변동을 검토하여 적절한 연계방식을 제시한다. 그리고 시간대별 소수력발전기의 발전량과 해당 배전선로의 부하량을 고려하여 기 설치된 보호계전기에 의한 단독운전 검출 능력을 검토하고자 한다.

  • PDF

t 분포 퍼센트점의 직접근사공식 (Direct approximations for t percentage points)

  • 김현철;송규문;허문렬
    • 응용통계연구
    • /
    • 제2권1호
    • /
    • pp.48-53
    • /
    • 1989
  • 본 연구에서는 t 분포 백분위점을 구하는 방법으로 표준정규분포의 백분위점을 이용하는 간접근사공식들과는 달리 p와 n만의 직접근사공식을 찾았다. Hoaglin이 $\chi^2$분포에 적용했던 탐색적분석과정을 거쳐서 찾아낸 이 공식은 그 형태가 간단하여 일상적인 자료분석에서 손쉽게 이용될 수 있을 뿐만 아니라 최대 상대오차가 1.2%밖에 되지않는 좋은 공식이다.

SVD를 기반으로 한 고차원 데이터 및 질의 집합의 생성 (An SVD-Based Approach for Generating High-Dimensional Data and Query Sets)

  • 김상욱
    • 정보기술과데이타베이스저널
    • /
    • 제8권2호
    • /
    • pp.91-101
    • /
    • 2001
  • Previous research efforts on performance evaluation of multidimensional indexes typically have used synthetic data sets distributed uniformly or normally over multidimensional space. However, recent research research result has shown that these hinds of data sets hardly reflect the characteristics of multimedia database applications. In this paper, we discuss issues on generating high dimensional data and query sets for resolving the problem. We first identify the features of the data and query sets that are appropriate for fairly evaluating performances of multidimensional indexes, and then propose HDDQ_Gen(High-Dimensional Data and Query Generator) that satisfies such features. HDDQ_Gen supports the following features : (1) clustered distributions, (2) various object distributions in each cluster, (3) various cluster distributions, (4) various correlations among different dimensions, (5) query distributions depending on data distributions. Using these features, users are able to control tile distribution characteristics of data and query sets. Our contribution is fairly important in that HDDQ_Gen provides the benchmark environment evaluating multidimensional indexes correctly.

  • PDF

Comparative Analysis of a Competitive Technology for a Major Electrical Power System

  • Koo, Young-Duk;Kim, Eun-Sun;Park, Young-Seo
    • Journal of information and communication convergence engineering
    • /
    • 제2권4호
    • /
    • pp.243-246
    • /
    • 2004
  • Currently, advanced countries invest lots of efforts to develop improvement of electric power production and supply, confronting environmental problems and new energy development. They set up long term plan focusing on electric power transmission infrastructure construction technology, establishment of the customer care service network using electric technologies, improvement of economic productivity by innovative electric technology, prevention of global warming gas and clean and efficient energy use etc. Comparing to those countries, the level of technologies that we have are in behind and moreover, technological resources are limited. Therefore, Korea is required to reconsider efficient distribution of R&D investment by concentrating on limited R&D resources to important technologies which could be stepping stone to gain competitive advantage. It can be done through comparative analysis of electric technologies among advanced countries and analysis of electric technology development policy.

Electrical Technologies for Grid Integration of Ocean Wave Power into the UK National Grid

  • Ahmed, Tarek
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.320-327
    • /
    • 2010
  • In this paper, multiple offshore wave energy converters with different output characteristics are connected to one power distribution substation. The connection between the power take-off of the different wave energy converters and the electrical power transmission system is presented in order to investigate whether multiple wave energy converters can augment energy yield and improve network integration capabilities. Moreover, the model of an array of wave energy converters is developed with the goal of analyzing the effects of the offshore wave farm on the electrical network to which it is connected. It is also developed to ensure that the electricity generated by the array is sufficiently controllable, and of a quality that can be integrate into the electricity supply network without unduly increasing the cost of connection, production or delivery.

통계적 분석 방법을 이용한 발전설비의 평균수명 계산 (Calculating Mean Life of Generators with Aging failures Data Using Data Analytic Method)

  • 이성훈;이승혁;김진오;전동훈;김태균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.464-466
    • /
    • 2004
  • This paper proposes a method to consider an aging failure probability and survival probability of power system components unlike uses only aging failure probability in existing mean life calculation. The estimates of the mean and its standard deviation is calculated by using Weibull distribution and each estimated parameters is obtained from Data Analytic Method (Type II Censoring). The parameter estimation using Data Analytic Method is simpler and faster than a traditional calculation method. This paper shows how to calculate the mean life and its standard deviation by the proposed method and illustrates a exactness using real historical records of generator utilities in korea.

  • PDF

산업용 전력계통의 안정도 유지를 위한 과전류계전기의 시간지연 한계 (Time Delay Limit of Over Current Relay for Maintaining Stability in Industrial Power Systems)

  • 김봉희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.190-192
    • /
    • 2002
  • The industrial power distribution system is a radial system and therefore usually protected with time delayed over current relays (OCR's). Proper time dial settings are provided at the OCR's. Meanwhile, the systems, where synchronous generator, or synchronous motors, or large induction motors are operating, can not be protected with only OCR's with time grading. This paper presents a technical limit and a suitable range of time delay in applying OCR's to clearing faults in the industrial power systems for maintaining stability. Dynamic simulations are made to show them employing a real power systems of a large petro-chemical complex.

  • PDF

새로운 등호제약조건을 고려한 개선된 유전알고리즘 기반의 송전손실 최소화 (IGA-Based Transmission Loss Minmization considering A New Equality Constraint)

  • 채명석;이명환;김병섭;신중린;임한석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.104-106
    • /
    • 2000
  • This paper presents an algorithm for optimal reactive power dispatch problem based on Improved Genetic Algorithm(IGA). Optimal Reactive Power Dispatch (ORPD) is particularized to the minimization of transmission line losses by suitable selection of generator reactive power outputs and transformer tap setting. For the objective, in this paper, Loss Re-Distribution Algorithm(LRDA) is new applied to the equality constraint of ORPD. The proposed method has been evaluated on the IEEE 30 bus system. Results of the application of the method are compared with a base case.

  • PDF

풍하중을 받는 태양광 추적 구조물의 응력해석 (Stress Analysis on a Structure of Solar Tracker Subjected to Wind Load)

  • 김용우;김원봉
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.747-754
    • /
    • 2012
  • A solar power generator is usually installed outdoors and it is exposed to extreme environments such as snow weight and wind loading. The solar tracker structure should be designed to have sufficient stiffness and strength against such loads. In this paper, simulations are performed by varying the parameters such as wind directions, wind speeds and the pose of the solar panel to evaluate the effects of extreme wind on solar tracker. As the effects of wind load, maximum displacement and maximum equivalent stress in the solar tracker are calculated. Finite element stress analysis is carried out by using the pressure distribution that is obtained by prior wind load analysis due to the flow around the solar tracker. The stress analysis of solar tracker to check and/or improve structural robustness provides some useful instructions for structural design or revision of solar tracker.