• Title/Summary/Keyword: Distribution generator

Search Result 547, Processing Time 0.04 seconds

A Study on the Development of Underground Facility Management System using UFSN (UFSN의 지하시설물관리 시스템 적용에 관한 연구)

  • Kwon, Hyuk-Jong;Lim, Hyung-Chang;Song, Byung-Hoon;Kim, Jung-Hoon;Han, Jae-Il
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.2
    • /
    • pp.9-15
    • /
    • 2008
  • In this paper, we carried out studying for real-time monitoring method about water distribution information of flow, flux, pressure and the vibrations, that facility management system checks it by using UFSN sensors. We developed UFSN sensing generator, gateway, and middleware, and defined UFSN sensing data format. Also we verified sending sensing data. We have monitored water distribution based on GIS drawing in real-time by storing sensing data in existing Underground Facility Management System.

  • PDF

The Field Coil End Effect of HTS Synchronous Motor (고온초전도 동기모터의 계자코일 단부의 영향)

  • 백승규;권운식;손명환;이언용;권영길
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.276-279
    • /
    • 2003
  • The superconducting synchronous machine(S.S.M) including generator and motor has different electromagnetic structure from the conventional machine. With the help of superconductor having much higher operating current density than normal conductor, S.S.M can eliminate most of iron core filling inside of the conventional machine. This air-cored structure could be analysed and designed theoretically based on 2-dimensional(2-D) magnetic field distribution assuming that the windings are extended infinitely toward the axial direction. However the actual structure of S.S.M has the end regions interconnecting the straight parts of the same cross-section with the 2-D model. Therefore, this actual 3-D model has smaller field distribution than the 2-D model. In this paper, we consider the effect of the end regions on the output of a HTS model motor and suggest more accurate design approach through comparison of 2-D and 3-D magnetic field analysis.

  • PDF

Propagation of Lightning Surges on Power AC Lines through Distribution Transformers (배전용 변압기를 통한 저압전원선으로의 뇌서지 전파)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Dong-Moon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.468-471
    • /
    • 2002
  • A strong need to improve the quality of electric power is increased because of increasing use of the sensitive and small-sized electronic devices. The surges on the low-voltage ac power lines are induced by nearby lightning return strokes, and the facilities for HA, OA, FA, ME as well as computer are easily damaged by high-voltage transients. The behaviors of lightning surge characteristics transferred from the primary winding to the secondary winding in distribution transformers using a Marx generator were experimentally investigated. The transfer characteristics of lightning surge associated with a custom service ground of secondary side were also examined.

  • PDF

Finite Element Software Package for Analysis of Electric Field Distribution in Human Body (유한요소법에 의한 인체내 전계분포 해석 용 소프트웨어의 개발)

  • Woo, Eung-Je
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.66-69
    • /
    • 1993
  • We have developed a software package for the analysis of electric field distribution in human body. It includes the graphical finite element mesh generator, linear system of equations solver using sparse matrix and vector technique, and post-processor for the display of the results. This software package can be used in various research areas of biomedical engineering where we inject current or apply voltage to human body. The software package was developed on Macintosh II computer and the size of the model is only limited by the main memory.

  • PDF

Investigation of the Estimation of Time-Varying Voltage Sags Considering the Short Circuit Contributions of Rotating Machines (회전기의 기여에 의한 시변성의 순간전압강하 예측에 관한 연구)

  • Yun Sang-Yun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.6
    • /
    • pp.315-322
    • /
    • 2005
  • In this article, 1 would like to explore the estimation method of time-varying voltage sags in large industrial systems considering the short circuit contributions of rotating machines. For the power distribution system of KEPCO(Korea Electric Power Corporation), the magnitude of initial symmetrical short circuit current is generally not changed. However, in industrial systems which contain a number of rotating machines, the magnitude of voltage sag is generally changed from the initial to the clearing time of a fault due to the decreasing contribution of rotating machines for a fault current. The time-varying characteristics of voltage sags can be calculated using a short circuit analysis that is considered the time-varying fault currents. For this, the prediction formulations of time-varying voltage sags are proposed using a foreign standard. The proposed method contains the consideration of generator and motor effects. For the test of proposed formulations, a simple system of industrial consumer is used for the comparison conventional and proposed estimation method of voltage sag characteristics.

Power Control Methods for Microgrid with Multiple Distributed Generators (다중 분산전원으로 구성된 마이크로그리드의 유무효전력 제어원리 연구)

  • Chung, Il-Yop;Won, Dong-Jun;Moon, Seung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.582-588
    • /
    • 2008
  • Microgrids are new distribution level power networks that consist of various electronically-interlaced generators and sensitive loads. The important control object of Microgrids is to supply reliable and high-quality power even during the faults or loss of mains(islanding) cases. This paper presents power control methods to coordinate multiple distributed generators(DGs) against abnormal cases such as islanding and load power variations. Using speed-droop and voltage-droop characteristics, multiple distributed generators can share the load power based on locally measured signals without any communications between them. This paper adopts the droop controllers for multiple DG control and improved them by considering the generation speed of distribution level generators. Dynamic response of the proposed control scheme has been investigated under severe operation cases such as islanding and abrupt load changes through PSCAD/EMTDC simulations.

Recent Technology Trends of Free-Space Quantum Key Distribution System and Components (무선 양자암호통신 시스템 및 부품 최신 기술 동향)

  • Youn, C.J.;Ko, H.;Kim, K.J.;Choi, B.S.;Choe, J.S.
    • Electronics and Telecommunications Trends
    • /
    • v.33 no.6
    • /
    • pp.94-106
    • /
    • 2018
  • A quantum key distribution (QKD) provides in principle an unconditional secure communication unlike the standard public key cryptography depending on the computational complexity. In particular, free-space QKD can give a secure solution even without a fiber-based infrastructure. In this paper, we investigate an overview of recent research trends in the free-space QKD system, including satellite and handheld moving platforms. In addition, we show the key components for a free-space QKD system such as the integrated components, single photon detectors, and quantum random number generator. We discuss the technical challenges and progress toward a future free- space QKD system and components.

Design and Implementation of Cyber Warfare Training Data Set Generation Method based on Traffic Distribution Plan (트래픽 유통계획 기반 사이버전 훈련데이터셋 생성방법 설계 및 구현)

  • Kim, Yong Hyun;Ahn, Myung Kil
    • Convergence Security Journal
    • /
    • v.20 no.4
    • /
    • pp.71-80
    • /
    • 2020
  • In order to provide realistic traffic to the cyber warfare training system, it is necessary to prepare a traffic distribution plan in advance and to create a training data set using normal/threat data sets. This paper presents the design and implementation results of a method for creating a traffic distribution plan and a training data set to provide background traffic like a real environment to a cyber warfare training system. We propose a method of a traffic distribution plan by using the network topology of the training environment to distribute traffic and the traffic attribute information collected in real and simulated environments. We propose a method of generating a training data set according to a traffic distribution plan using a unit traffic and a mixed traffic method using the ratio of the protocol. Using the implemented tool, a traffic distribution plan was created, and the training data set creation result according to the distribution plan was confirmed.

Effect of Injector Number on Combustion Characteristics of Full-scale Gas Generators (분사기 수에 따른 실물형 가스발생기 연소특성)

  • Ahn, Kyu-Bok;Seo, Seong-Hyeon;Lim, Byoung-Jik;Kim, Jong-Gyu;Lee, Kwang-Jin;Han, Yeoung-Min;Choi, Hwan-Seok
    • Aerospace Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.128-135
    • /
    • 2007
  • Combustion characteristics of full-scale gas generators were studied experimentally by changing the injector number installed at the injector head. Three full-scale gas generators were utilized; they have same total mass flow rate but mass flow rates per injector are different. Thirteen, nineteen and thirty seven injectors, which have internal-mixing and double-swirl characteristics, are distributed in injector heads, respectively. The results showed that pressure fluctuations in the gas generators with 13 and 19 injectors didn't occur around longitudinal resonant frequency, however longitudinal-mode pressure fluctuation appeared slightly in the gas generator with 37 injectors. As the number of injectors increased, deviations of temperature distribution in the combustion chamber decreased gradually, but the damage of injector LOx posts became a little severe.

  • PDF

Effect of Injector Design on Combustion Characteristics of Full-scale Gas Generators (분사기 설계에 따른 실물형 가스발생기 연소특성 비교)

  • Ahn, Kyu-Bok;Seo, Seong-Hyeon;Lee, Kwang-Jin;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.309-315
    • /
    • 2006
  • Effects of injector or design on combustion characteristics of full-scale gas generators were studied. Three full-scale gas generators, which have same total mass flow rate but mass flow rate per injector is different depending on their designs, were manufactured. Thirteen, nineteen and thirty seven injectors, which have internal-mixing and double-swirl characteristics, are distributed in injector heads, respectively. The results showed that special pressure fluctuations in the gas generators with 13 and 19 injectors didn't appear around longitudinal resonant frequency, but small longitudinal-mode instability appeared in the gas generator with 37 injectors. As the number of injectors installed in injector heads increased, temperature distribution in combustion chambers showed small deviations, but the damage of LOx posts increased.

  • PDF