• Title/Summary/Keyword: Distribution Transformers

Search Result 202, Processing Time 0.031 seconds

A study for the overload and fault protective device of pole transformers (주상변압기 과부하 및 고장보호장치 개발에 관한연구)

  • Choi, Bong-Il;Lim, Chang-Ho;Kim, Chang-Kyung;Kim, Young-Rae;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.67-69
    • /
    • 1992
  • This paper presents the new protective device which is developed specifically for use in oil filled distribution transformers. This device is mounted Inside of the transformer and connected between the secondary winding and the secondary bushings. It provides both fault and overload protection to the transformer, and visual warning of the existence of uneconomical loading conditions. It Is available in thermal/magnetic operating device depending upon fault duty required.

  • PDF

Diagnosis of Cast Resin Transformer Using Analysis of Surface Temperature Distribution (표면온도분포 분석을 이용한 몰드 변압기 진단)

  • Lim, Yong-Bae;Chun, Jong-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.444-447
    • /
    • 2003
  • All objects with some temperature above absolute zero radiate in the infrared. The intensity of the infrared radiated from a object defends on the condition and temperature on the surface of the one. The present, these techniques are frequently adopted into diagnosis for electricity equipments. Simply, however, the applied techniques are passive thermal testing for the detection of loosened terminals and overcurrent. In this paper, a infrared thermal imager was applied to high voltage windings of cast resin transformers, and the accumulated value of the result temperatures was used for evaluating remained lifetime of them. At each aging level, dielectric loss tangent test was carried out. The results offered capabilities for deciding the condition of the transformers suffering difficulties to diagnose.

  • PDF

Study on Insulation Design of Surge Voltages for Convex Winding type Ribbon Core Transformer (Convex형 권선배치방식을 취한 권철심변압기의 충격파절연설계에 관한 연구)

  • 황영문;조철제;김중한
    • 전기의세계
    • /
    • v.22 no.3
    • /
    • pp.13-24
    • /
    • 1973
  • In this report, as a method to solve the problems on impulse insulation coordination in ribbon core transformer owing to it's BIL stepping up, new design to alter winding distribution of multiple-layer concentric winding to Convex type winding is proposed. The main focus of this method is to settle the weakness of axial direction insulation strength and as a result of theoretical analysis through experiment of model transformers, the following conclusions are obtained; (a) As the electric loadings in a design which increases by strengthenning axial direction insulation endurance in presently avarilable transformers owing to it's BIL stepping up can be restricted in Convex type winding, reasonable design will be suited to the transformer with higher BIL. (b) Convex type winding is a very improved insulation design in respect of insulation coordination because it has shield plate effect to even impulse oscillation. (c) There is a disadvantage to cause leakage flux to increase in Convex type winding, however, the constancy of electric loadings in a design in spite of BIL stepping up restricts the increase of leakage flux to some extent.

  • PDF

The Study on Application of Hybrid Insulation System for Thermally Upgraded Distribution pole Transformers (주상변압기 열적 특성 향상을 위한 복합절연 시스템 적용)

  • Lee, B.S.;Song, I.K.;Lee, J.B.;Kim, D.M.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1896-1898
    • /
    • 2002
  • In this paper, to developing thermally and mechanically upgraded ones, we dismounted pole transformers used in the fields for over 13 years and conducted aged oil analysis. Also, when the cellulose and aramid papers in test cell were aging with oil at $130^{\circ}C$ for 3000 hours, with the testing period cellulose paper deteriorated more rapidly than the others. For example dielectric strength and dissipation factor of papers deteriorated with aging time. For evaluation of thermal aging characteristics, a mineral oil-immersed transformer was constructed with hybrid insulation system comprised of aramid paper and cellulose insulation. A Hybrid system has economic advantages. Cellulose materials are confined to cooler regions of the transformer winding. And aramid papers are served to insulate contact parts of hot conductors.

  • PDF

A Study on Standardization of the Electric Facilities for distribution & Translations - Focused on the Electric Facilities in Subway Stations - (수변전설비의 표준화에 관한 연구 - 지하철 역사전기설비를 중심으로 -)

  • Cho, Sung-Pil;Kang, Cha-Nyeong;Kim, Hak-Lyun
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.838-843
    • /
    • 2006
  • In our modern society, such electric facilities as lighting, elevators, water supplies, drainages, waste water treatments and landscape lighting are being more enlarged, diversified and technology-intensive owing to outstanding technological development, while they require reliable and safe electricity. On the other hand, as more electric energy is consumed with more complicated systems operated, any accident from a personal electric system is likely to have wider spreading effects. In particular, the electric receivers and transformers installed for such public facilities as subway stations require highest safety, reliability and economy, but such requirements tend to be less considered than such financial requirements as budget conditions, much less their safety and reliability. In such a circumstance, this study was aimed at suggesting some standards for safe, reliable and economic subway electric systems in terms of their scale, location and uses. Specifically, this study put forwards the ways to optimize and standardize the electric systems including receivers and transformers for subway stations in order to make them safer, more reliable and economic.

  • PDF

The Applied Technology of Mold Transformer for Outdoor Use (옥외 주상용 몰드 변압기인 적용 기술)

  • Han, Se-Won;Cho, Han-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.23-28
    • /
    • 2000
  • Insulator systems using resin casting apparatus are useful to realize the high capacity, small size, and combined electric power equipments, and are expected to bring various advantages. In Korea, epoxy resin molded apparatus have been restricted to indoor uses till now. On the other hand, in Europe, molded insulators and transformers and so forth have been practically used since the former half of 1960's. Recently, investigation on epoxy resin materials and molded apparatus for outdoor use have ben intensively carried out. Probably, this is because electric power outdoor apparatus such as distribution transformer can be given multi-functions by using outdoor epoxy resin compound This study describes the trend on the development of epoxy mold transformers, and important technologies applied for outdoor use.

  • PDF

A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer (식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구)

  • Jeong, Jung-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.

Development of Distribution Transformer with Condition Monitoring Sensors and Data Processing Unit (상태감시용 센서를 내장한 배전용 변압기 및 데이터 처리장치 개발)

  • Jung, Joon-Hong;Yu, Nam-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.201_202
    • /
    • 2009
  • This paper presents a design methodology of a distribution transformer with condition monitoring sensors and its data processing unit. The proposed distribution transformer includes various type of condition monitoring sensors such as load current/voltage, temperature and heat aging of insulating oil. The data processing unit is installed at the distribution transformer site. It integrates sensed data and transmits these to a central server system. The proposed distribution transformer and its data processing unit will help an on-line condition monitoring system for distribution transformers.

  • PDF

Analysis of Surge Behavior and Protection Method in the Underground Distribution Systems with Branch Lines (분기선로가 포함된 지중배전계통에서 서지특성 해석 및 보호방안에 관한 연구)

  • Lee, Jang-Geun;Lee, Jong-Beom;Lee, Jae-Bong;Kim, Byoung-Sook
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.148-150
    • /
    • 2006
  • This paper describes the overvoltage at the branch line in underground distribution systems when the direct lightning surge strikes on conductor of overhead line. Distribution systems are very complex because it includes many branch lines, transformers, switches and so on. Therefore model system consists of overhead distribution lines, underground cable include branch lines, lightning source and switches. Analysis are performed using EMTP to understand and evaluate the surge behavior on branch lines considering various conditions in underground distribution systems. Simulation results show overvoltage with location in various cases. It is evaluated that result will be used to establish protection methods in actual underground distribution systems.

  • PDF

Analysis of Surge behavior on Branch Line in the Underground Distribution Systems (지중배전계통에서의 분기선로의 서지특성 해석)

  • Lee, Jang-Geun;Lee, Jong-Beom;Lee, Jae-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.157-158
    • /
    • 2006
  • This paper describes the overvoltage of branch line in underground distribution systems when the direct lightning surge strikes on conductor of overhead line. Distribution systems are very complex because that includes so many branch lines, transformers, switches and so on. Therefor model systems consist of overhead distribution lines, underground cable include branch lines, lightning source and switches. Those are established by EMTP/ATPDraw. Simulation analyzes surge behavior on branch lines considering various conditions in underground distribution systems. Simulation results shoe overvoltage with location in various cases.

  • PDF