• Title/Summary/Keyword: Distribution Technology

Search Result 12,831, Processing Time 0.036 seconds

A New Method for Measuring the Dose Distribution of the Radiotherapy Domain using the IP

  • Homma, Mitsuhiko;Tabushi, Katsuyoshi;Obata, Yasunori;Tamiya, Tadashi;Koyama, Shuji;Kurooka, Masahiko;Shimomura, Kouhei;Ishigaki, Takeo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.237-240
    • /
    • 2002
  • Knowing the dose distribution in a tissue is as important as being able to measure exposure or absorbed dose in radiotherapy. Since the Dry Imager spread, the wet type automatic processor is no longer used. Furthermore, the waste fluid after film development process brings about a serious problem for prevention of pollution. Therefore, we have developed a measurement method for the dose distribution (CR dosimetry) in the phantom based on the imaging plate (IP) of the computed radiography (CR). The IP was applied for the dose measurement as a dosimeter instead of the film used for film dosimetry. The data from the irradiated IP were processed by a personal computer with 10 bits and were depicted as absorbed dose distributions in the phantom. The image of the dose distribution was obtained from the CR system using the DICOM form. The CR dosimetry is an application of CR system currently employed in medical examinations to dosimetry in radiotherapy. A dose distribution can be easily shown by the Dose Distribution Depiction System we developed this time. Moreover, the measurement method is simpler and a result is obtained more quickly compared with film dosimetry.

  • PDF

The impact study on fuel economy of electric vehicle according to the test mode characteristics (시험모드 특성이 전기자동차의 에너지소비효율에 미치는 영향 연구)

  • Noh, Kyeong-Ha;Lim, Jae-Hyuk;Kim, Sung-Woo;Kim, Ki-ho;Ha, Jong-Han;Oh, Sang-Gi
    • Journal of Power System Engineering
    • /
    • v.19 no.6
    • /
    • pp.39-46
    • /
    • 2015
  • With rising fuel costs and the depletion of fossil fuels, electric vehicles of high efficiency has been increasing interest. although high-performance battery continually is developing, Electric vehicles is not satisfied with the characteristics of the environment. In this study, By using the current fuel economy testing methods(5-cycle test), until the fully discharged battery electric vehicles is evaluated for a variety of environmental and operating conditions. As a result, Electric vehicles showed a low energy consumption efficiency in low temperature and rapid acceleration, deceleration in the operating environment compared with normal temperature.

Numerical Study on Coolant Flow Distribution at the Core Inlet for an Integral Pressurized Water Reactor

  • Sun, Lin;Peng, Minjun;Xia, Genglei;Lv, Xing;Li, Ren
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.71-81
    • /
    • 2017
  • When an integral pressurized water reactor is operated under low power conditions, once-through steam generator group operation strategy is applied. However, group operation strategy will cause nonuniform coolant flow distribution at the core inlet and lower plenum. To help coolant flow mix more uniformly, a flow mixing chamber (FMC) has been designed. In this paper, computational fluid dynamics methods have been used to investigate the coolant distribution by the effect of FMC. Velocity and temperature characteristics under different low power conditions and optimized FMC configuration have been analyzed. The results illustrate that the FMC can help improve the nonuniform coolant temperature distribution at the core inlet effectively; at the same time, the FMC will induce more resistance in the downcomer and lower plenum.

Digital Bank Channel Distribution: Predictors of Usage Attitudes in Jakarta's Gen Z

  • Eko Retno, INDRIYARTI;Michael, CHRISTIAN;Henilia, YULITA;Titik, ARYATI;Regina Jansen, ARSJAH
    • Journal of Distribution Science
    • /
    • v.21 no.2
    • /
    • pp.21-34
    • /
    • 2023
  • Purpose: The goal of this study is to examine what makes young people more likely to use digital banking. This is because digital banking services and their distribution channels are technologically advanced, which can be a double-edged sword between ease of use and resistance to technology. Research design, data and methodology: This study included 320 participants from generation Z in Jakarta who use digital bank and used a quantitative method with PLS-SEM. Results: This study explains how, in addition to usefulness, costs, and self-efficacy, resistance to technology has a direct effect on usage attitudes. Meanwhile, if the attitude of use is preceded by aspects of usefulness, self-efficacy, and awareness, resistance to technology will be felt indirectly. Conclusions: This demonstrated that most discussed factors, such as Ease-of-Use and security of use, are important for Generation Z users but no longer a major consideration in accepting digital banking. Aside from being more open to the use of technology in digital banks, Generation Z also desires a balance of technology services and benefits. The limitations of this study are that it excludes social variables, uses certain generations, and limits the research area to one large city, which can be expanded in future studies.

The Effect of Investing into Distribution Information and Communication Technologies on Banking Performance the Empirical Evidence from an Emerging Country

  • PHAN, Anh;LU, Chi Huu;HOANG, Lam Xuan;NGUYEN, Phuong Minh
    • Journal of Distribution Science
    • /
    • v.20 no.6
    • /
    • pp.43-56
    • /
    • 2022
  • Purpose: This study aims to investigate the impact of investing into technology development on banking performance in an emerging country. Research design, data and methodology: Based on the data of 12 commercial banks listed in Vietnam from 2011 to 2019 and performing multivariable regression analyses as well as conducting a variety of robustness tests, we carry out the empirical investigation to discover this impact. Results: Our empirical evidence shows that these spending help to improve significantly performance of banks. Particularly, the technology expenditures have positive effect on the net interest margin and the non-interest income in which the level of influence on the latter is relatively remarkable in comparison with the former. At the same time, the result does not support the view that increasingly spending on technology may lead banks to face the risk of instability. Conclusions: Overall, our empirical analysis indicates that increasing investment into distribution information and communication technologies will help to enhance business strategies of banks and thus we advocate the bright side of technology development and digitalization in banking sector. We believe that the research is useful for both managers, regulators and policy makers in Vietnam as well as in countries having similar financial structure.

A study on An Optimal Protection System for Power Distribution Networks by Applying Multi-Agent System (Multy-agent system을 애용한 배전계통 최적 보호시스템 연구)

  • Jung, K.H.;Min, B.W.;Lee, S.J.;Choi, M.S.;Kang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.299-301
    • /
    • 2003
  • In this paper, a protection system using Multi-Agent concept for power distribution network is proposed. Multi agent system consist of Feeder agent, OCR(Over Current Relay) agent, Recloser agent and Switch agent. An agent calculates and corrects its parameter by itself through communication with neighboring agents and its own intelligence algorithm. Simulations in a simple distribution network show the effectiveness of the suggested protection system. Multi-Agent System, protection of distribution network, Communication.

  • PDF

Experimental study of bubble flow behavior during flow instability under uniform and non-uniform transverse heat distribution

  • Al-Yahia, Omar S.;Yoon, Ho Joon;Jo, Daeseong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2771-2788
    • /
    • 2020
  • Experiments are conducted to study bubble flow behavior during the instability of subcooled boiling under uniform and non-uniform transverse heating. The non-uniform heat distribution introduces nonuniform bubble generation and condensation rates on the heated surface, which is different from the uniform heating. These bubble generation and condensation characteristics introduce a non-uniform local pressure distribution in the transverse direction, which creates an extra non-uniform pressure on the flowing bubbles. Therefore, different bubble flow behavior can be observed between uniform and non-uniform heating conditions. In the uniform heating, bubble velocity fluctuations are low, and the bubbles travel straight along the axial direction. In the non-uniform heating, more fluctuation in the bubble velocity occurs at low mass flow rate and high subcooled inlet temperatures, and reverse flow is observed. Additionally, the bubbles show a zigzag trajectory when they pass through the channel, which indicates the existence of cross flow in the transverse direction.

Evaluation of Carbon Fiber distribution in Unidirectional CF/Al Composites by Two-Dimensional Spatial Distribution Method

  • Lee, Moonhee;Kim, Sungwon;Lee, Jongho;Hwang, SeungKuk;Lee, Sangpill;Sugio, Kenjiro;Sasaki, Gen
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.1
    • /
    • pp.29-36
    • /
    • 2018
  • Low pressure casting process for unidirectional carbon fiber reinforced aluminum (UD-CF/Al) composites which is an infiltration route of molten Al into porous UD-CF preform has been a cost-effective way to obtain metal matrix composites (MMCs) but, easy to cause non-uniform fiber distribution as CF clustering. Such clustered CFs have been a problem to decrease the density and thermal conductivity (TC) of composites, due to the existence of pores in the clustered area. To obtain high thermal performance composites for heat-sink application, the relationship between fiber distribution and porosity has to be clearly investigated. In this study, the CF distribution was evaluated with quantification approach by using two-dimensional spatial distribution method as local number 2-dimension (LN2D) analysis. Note that the CFs distribution in composites sensitively changed by sizes of Cu bridging particles between the CFs added in the UD-CF preform fabrication stage, and influenced on only $LN2D_{var}$ values.

Analysis of Discomfort Glare by luminous intensity distribution of Marine Indoor Luminaires (선박용 실내조명기구의 배광에 따른 불쾌글레어 분석)

  • Cho, Sang-Hee;Kim, Kun-Yul;Yu, Young-Moon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.18-25
    • /
    • 2014
  • In this paper, tried to find out the proper luminous intensity distribution for the cabin with low-level height by analyzing the changing tendency of discomfort glare according to luminous intensity distribution of marine indoor luminaires using Unified Glare Rating(UGR). First, we analyzed UGR of the indoor luminaires in the existing cabin, and then evaluated influence on luminous intensity distributions of marine indoor luminaire. The results showed that $cos^2{\Theta}$ distribution got almost low UGR results regardless of height and UGR 16.5 in cabin height of 2m. However, Gaussian distribution with the same beam angle showed that UGR results consistently increased by getting lower height and UGR 20.7 in the same height. In conclusion, the $cos^2{\Theta}$ distribution in consideration of luminous intensity on the direction of observer's eye was appropriate for general cabin indoor luminaires because it decreased UGR in the low-level height.

A Study on the Characteristics of Temperature Distribution according to Material and Position of Filter in a Diesel Particulate Filter (필터의 재질 및 위치에 따른 DPF 내부의 온도 분포 특성에 관한 연구)

  • Kim, Gyu-Sung;Park, Sung-Cheon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.6
    • /
    • pp.903-909
    • /
    • 2012
  • This study analyzed the temperature distribution in DPF with five partitioned electric heaters. The temperature distribution in DPF is an important design factor for regeneration and durability of filter. The design Factors that influence the temperature distribution in DPF there are several. In this study, the characteristics of temperature distribution in DPF were analyzed according to the following changes. First, the thermal conductivity of the filter was analyzed about effect on the durability of the filter. Second, the length from exhaust manifold to inlet of DPF was analyzed about effect on the temperature distribution in DPF. The boundary conditions of analysis has been verified with comparison to the results of existing experimental study and the numerical analysis. Based on the identified boundary condition, on assuming the condition of the actual driving, the temperature distribution in DPF was analyzed according to material properties of filter and the position of DPF.