• Title/Summary/Keyword: Distribution Automation

Search Result 469, Processing Time 0.024 seconds

The Additional Functions and Data Transmission Flow Diagram for Effective Operation of Distribution Automation System (배전자동화시스템의 효율적인 운용을 위한 구가기능 및 정보전송체계)

  • Lee, Jung-Ho;Ha, Bok-Nam;Cho, Nam-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.211-213
    • /
    • 1998
  • This paper introduces the additional remote monitoring and remote setting functions needed to operate the distribution automation system effectively. we compare the additional functions with the old functions. The remote setting of minimum trip value of fault indicator is an example of additional function. It saves time and line-man's power. Also this paper describes the data transmission flow diagram for operation of distribution automation system using wireless communication method.

  • PDF

Load Flow Analysis for Distribution Automation System based on Distributed Load Modeling

  • Yang, Xia;Choi, Myeon-Song;Lim, Il-Hyung;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.329-334
    • /
    • 2007
  • In this paper, a new load flow algorithm is proposed on the basis of distributed load modeling in radial distribution networks. Since the correct state data in the distribution power networks is basic for all distribution automation algorithms in the Distribution Automation System (DAS), the distribution networks load flow is essential to obtain the state data. DAS Feeder Remote Terminal Units (FRTUs) are used to measure and acquire the necessary data for load flow calculations. In case studies, the proposed algorithm has been proven to be more accurate than a conventional algorithm; and it has also been tested in a simple radial distribution system.

The study of linkage between systems to make the database of distribution automation system (대규모 배전자동화 시스템의 데이터베이스 구축을 위한 시스템 연계 연구)

  • Ha, B.N.;Kang, M.H.;Cho, N.H.;Jeong, C.S.;Kim, J.S.;Lee, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.419-421
    • /
    • 2001
  • The large distribution automation system for metropolitan city was developed in KEPCO just recently. This system has many functions for remote control and data acquisition, and it will be linked the other computer aided system such as NDIS(new distribution automation system) and SCADA(supervisory control and data acquisition) to construct the database of DAS(distribution automation system).

  • PDF

Development of a management control system for KODAS (KODAS 관리제어 시스템 개발)

  • Kim, K.H.;Nam, K.Y.;Kim, W.T.;Seo, J.I.;Ko, H.J.;Lee, J.K.;Yyun, T.Y.;Kim, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.424-426
    • /
    • 1993
  • Main function of distribution automation system can be summarized as feeder automation, telemetering, load control and facility information management. But in most cases, one or two of the above mentioned functions are developed in one distribution automation system. Which function to be developed in the automation system depends on the distribution system's characteristics. The title KODAS means $\underline{KO}$rea $\underline{D}$istribution $\underline{A}$utomation $\underline{S}$ystem. Management Korea for KODAS is central control station of distribution system, which is composed of several substations. This paper describes computer system, software tools, data base design data acqusition scheme and information flow.

  • PDF

A Study on the Prioritization of Sectional Switchgear Replacement for Intelligent Distribution Automation in Distribution System (배전지능화 시스템을 위한 배전계통 구분개폐기 교체 우선순위 결정에 관한 연구)

  • Sung, In-Je;Chai, Hui-Seok;Moon, Jong-Fil;Seo, In-Yong;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.51-58
    • /
    • 2015
  • Intelligent distribution automation system includes operating a switchgear of distribution system remotely when switchgear are not available to operate quickly. This system makes it possible to reduce the interrupt time. It also aims to improve the reliability of customers. Currently, Intelligent distribution automation improves the reliability by replacing manual switchgear, which is installed as sectional switchgear. However the prioritization of the replacement for the switchgear is required for its intellectualization. Many studies have been conducted related with prioritization of switchgear replacement. But it is difficult to interpret and apply to the power distribution system. That is because most of the studies just considers customer numbers for prioritizing the replacement. In this paper presents an algorithm to determine the intelligent swichgear replacement priority considering customer number, load quantity and interruption cost. Further, this algorithm is verified by using system reliability index.

A Study About Distribution Automation System Based on CIM (CIM 기반의 Distribution Automation System에 관한 연구)

  • Lee, Hee-Joo;Seo, Jeong-Il;Han, Ju-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.913-920
    • /
    • 2011
  • Distribution systems for operating the various systems should be operated organically. Distribution systems for organic operations extend the functionality of the system and system integration for the extension is doing. However, in systems integration for each unique non-standard definition of linkage and exchange systems are used. Non-standard definition of a unique linkage and exchange systems in the maintenance and expansion will result in many negative results. To solve these problems, the system and the exchange of information about the links between systems should define standards. IEC (International Electrotechnical Commission) power to solve these problems in the field of the Common Information Model (Common Information Model, CIM) standard (IEC61970, IEC61968) is defined as the transmission and distribution system integration and standardization for the exchange of information. In this paper, standardized system for building CIM-based distribution automation system should describe the process of building. In addition, the process of establishing a common information model needed (CIM) defined and associated services for a defined set of models is proposed in the standardization process.

A Study on the Protective Coordination of Distribution Automation System under Loop Operation (배전자동화 계통의 루프 운전시 보호협조에 관한 연구)

  • Lee, Hee-Tae;Moon, Jong-Fil;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1281-1286
    • /
    • 2009
  • As a general radial configuration of power distribution system, the various researches have being studied to change a radial configuration to network one such as smart, intelligent and micro grid for loop operation. If a radial configuration changes to network, protective coordination comes to the biggest problem. When a typical protective algorithm is applied to loop distribution system protection, the interrupted section is expanded, therefore, reliability grows worse. This paper presents the new protective method being able to apply to loop distribution system with Distribution Automation System (DAS) which separate the minimal faulted section. Through contingency analysis of the sustained and momentary fault, we analyzed the influence for radial configuration and loop configuration using interrupted area and proved the effectiveness of proposed method.

An feeder Automation System Using Active Database (능동 데이터베이스 이용한 배전선로 운전자동화)

  • 최상열
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.94-102
    • /
    • 2003
  • This paper presents active management of feeder automation systems using active database. DAS(Distribution Automation System) has been managed for feeder automation in passive manner. Therefore, feeder automation system has to be managed by operator when feeder overloadings is detected. It may be possible for propagating the feeder overloadings area by operator's mistake. To overcome this defect, the author proposed the feeder automation technique with active manner to obtain feasible feeder reconfiguration. Active database can manage feeder automation system by data driven monitoring of events and by corresponding actions without operator's intervening. To manage feeder automation system with active manner, production rule, active rule manager are designed. And active database system architecture for feeder automation system is proposed. Test results on the KEPCO's 108 bus distribution system show that the performance is efficient and robust.

The Standard for Installation of Automated Distribution Switch-gear in Multi-Line Faults (다중선로 고장을 고려한 배전자동화용 개폐기 설치기준)

  • Lee, Jung-Ho;Ha, Bok-Nam;Cho, Nam-Hun;Lim, Sung-Il
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1079-1081
    • /
    • 1999
  • This paper presents the standard for dividing/tieing the distribution lines and installing optimally the automated distribution switch-gear in multi-line faults. Also this paper recommends the distribution system design in consideration of the live load transfer of the concentrated load in the last load-side. This recommendation will be useful for designing the distribution network, developing the feeder automation software and operating the distribution automation system.

  • PDF