• 제목/요약/키워드: Distraction Factors

검색결과 30건 처리시간 0.022초

신연 골형성술시 신연속도에 따른 골형성 관여 인자의 발현 (EXPRESSION OF OSTEOGENESIS RELATED FACTORS ACCORDING TO DISTRACTION RATE IN THE DISTRACTION OSTEOGENESIS)

  • 지유진;김여갑
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권3호
    • /
    • pp.250-265
    • /
    • 2008
  • Distraction osteogenesis is a well-established clinical treatment for limb length discrepancy and skeletal deformities. Appropriate mechanical tension-stress is believed not to break the callus but rather to stimulate osteogenesis. In contrast to fracture healing, the mode of bone formation in distraction osteogenesis is primarily intramembranous ossification. Although the biomechanical, histological, and ultrastructural changes associated with distraction osteogenesis have been widely described, the basic biology of the process is still not well known. Moreover, the molecular mechanisms in distraction osteogenesis remain largely unclear. Recent studies have implicated the growth factor cascade is likely to play an important role in distraction. And current reserch suggested that mechanical tension-stress modulates cell shape and phenotype, and stimulates the expression of the mRNA for bone matrix proteins. The purpose of this study is to examine the pattern of expression of growth factors($TGF-{\beta}1$, IGF-I, bFGF) and extracellular matrix proteins(osteoclacin, osteonectin) related to osteogenesis by osteodistraction of the mandible in rabbits. 24 rabbits is used for this experiment. Experimental group are gradual distraction(0.7mm, twice/day), acute distraction(1.4mm, twice/day) and control group is only osteotomized. After 5 days latency, osteotomic site is distracted for each 7 days and 3.5 days. Consolidation period is 28 days. The animal is sacrificed at the 3th, 7th, 14th, 28th. The distracted bone is examined by immunohistochemical analysis and RT-PCR analysis. The results obtained from this study were as follow : No significant difference was found on clinical examination according to distraction rate, but gradual distraction was shown to improve regenerate bone formation on radiographic and histologic examination. Growth factors and extracelluar matrix proteins expression increased in distraction group than control group. From these results, it could be stated that graudal distraction is shown to improve and accelerate bone formation and mechanical stress like distraction has considerable effects on osteogenesis related factors. And rabbit is the most appropriate animal model for further reseach on the molecular mechanisms that mediate osteodistraction. It is believed that understanding the biomolecular mechanisms that mediate distraction osteogenesis may guide the development of targeted strategies designed to improve distraction osteogenesis and accelerate bone healing.

가토 하악골에서 신연 골형성술시 신연속도에 따른 TGF-$\beta$1, IGF-I, bFGF의 발현 (THE EXPRESSION OF TGF-$\beta$1, IGF-I, BFGF IN DISTRACTION OSTEOGENESIS ACCORDING TO DIFFERENT DISTRACTION RATES IN RABBIT'S MANDIBLE)

  • 신선아;지유진;송현철
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권3호
    • /
    • pp.205-217
    • /
    • 2005
  • Distraction osteogenesis is a technique of lengthening bone including soft tissue by gradual separation of surgically divided bone surfaces. Although the biomechanical, histological, and ultrastructural changes associated with distraction osteogenesis have been widely described, the molecular mechanisms governing the formation of new bone in distracted bone segments remain largely unclear. However, such information has significant clinical implications because it may enable targeted therapeutic manipulations designed to accelerate osseous regeneration. The purpose of this study was to evaluate the expression of TGF-$\beta$1, IGF-I and bFGF in distraction osteogenesis according to different distraction rates in a rabbit's mandible. When twenty-four adult rabbits underwent open osteotomy between the premolar and mental foramen, an external bilateral distraction device was applied. Latency was allowed for five days before distraction. Three different distraction rates were 0.7 mm/day (A, n=8), 1.4 mm/day (B, n=8) and 2.4 mm/day (C, n=8). The distraction device was activated with the same distraction rhythms of twice a day until 4.9 mm (A & B group) and 8.4 mm (C group) length gains was achieved. The animals were sacrificed at postoperative 3, 7, 14 and 28 days. The bony specimens were stained with H&E for histologic examination, and RT-PCR analysis was done for the identification of the expression of TGF-$\beta$1, IGF-I and bFGF. The results obtained from this study were as follows : The 0.7 mm/day and 1.4 mm/day distraction rate groups were shown to improve regenerative bone formation on radiographic and histologic examination. Also, TGF-$\beta$1, IGF-I and bFGF expression increased in the 0.7 mm/day and 1.4 mm/day distraction rate groups. But the 2.4 mm/day distraction rate group specimen was different with adjacent normal bone and hardly expressed of growth factors. These findings suggest that improved new bone formation in the 0.7 mm/day and 1.4 mm/day distraction rates is associated with enhanced expression of TGF-$\beta$1, IGF-I and bFGF by mechanical tension stress. Additionally, the 0.7 mm/day and 1.4 mm/day distraction rate groups were significantly different from the 2.4 mm/day distraction rate group in the expression of growth factors. According to the above results, it seems possible to apply a distraction rate of up to 1.4 mm/day a day in rabbit's mandible. And further studies are needed to evaluate growth factors of TGF-$\beta$1 and IGF-I, which are excellent in expression.

HMD기반 몰입형 VR 학습에서 방해요인, 프레즌스, 몰입, 학습효과 사이의 관계에 관한 연구 (A Study on the Relationship of Distraction Factors, Presence, Flow, and Learning Effects in HMD-based Immersed VR Learning)

  • 권종산
    • 한국멀티미디어학회논문지
    • /
    • 제21권8호
    • /
    • pp.1002-1020
    • /
    • 2018
  • Virtual reality (VR) technologies, which have been improved of late, offer experiences closer to reality than before. While VR technologies are expected to be an effective medium if used in learning content that cannot be offered in real life, distraction factors in VR technologies may prevent the users' presence and flow, making these technologies ineffective. Therefore, this study, through experiment and observation, analyzed the effect of distraction factors on the user's experience perception and learning effect when using HMD-based immersive VR. Experimental results revealed that the distraction factors were shown to have a negative, albeit not generally significant (except for tactile interactivity), effect on vividness, tactile interactivity, locomotive interactivity, presence, and flow. Ultimately, they were shown to have a negative effect on learning.

Rigid External Distraction (RED) II system을 이용한 중안면부 골 신장술시의 고려사항 (Considerations in Midface Distraction Osteogenesis Using RED (Rigid External Distraction) II System for Successful Treatment)

  • 양일형;백승학;남동석
    • 대한구순구개열학회지
    • /
    • 제7권2호
    • /
    • pp.107-121
    • /
    • 2004
  • Midface and maxillary distraction osteogenesis (DO) can be an alternative treatement modality for the craniofacial syndrome patients and cleft lip and palate patients. Rigid External Distraction (RED) II system has more advantages in the force vector control than the other types of distraction systems. Despite of increasing popularity of RED system there is few report on the failure factors. Some considerations should be pointed out in using RED II system for successful treatment; the rigidity of intraoral splint, complete separation of bony segment, and the cooperation of patients. Orthodontists, surgeons, and patients have the same amount of responsibility for the successful midface and maxillary DO using RED II system from the beginning to the end of the treatment.

  • PDF

백서 경골에서 신연속도에 따른 골형성 비교 연구 (A COMPARISON STUDY ON DISTRACTION OSTEOGENESIS IN THE RAT'S TIBIA ACCORDING TO DISTRACTION RATES)

  • 김부경;신상훈;김종렬
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권6호
    • /
    • pp.620-627
    • /
    • 2000
  • The purpose of this study is to investigate the clinical and histologic changes in distraction osteogenesis according to different distraction rates in the rat's tibia. Eighteen adult rats underwent open osteotomy and attachment of an external unilateral distraction device in the middle of left tibia. Latency was allowed for 7 days before distracton began. The distraction device was activated with varying distraction rates of 0.5mm, 1mm, 2mm and same rhythm of twice a day until 5mm length gain was achieved. The animals were sacrificed at post-distraction 4, 8 weeks to observe the bony healing states. At each group, clinical, radiographic and histologic studies were done. The results obtained from this study were as follows: 1. The 0.5mm group showed excellent osteogenesis than other groups. The new bone was formed by intramembranous bone formation mostly and endochondral bone formation partly. 2. The 1mm group showed delayed osteogenesis and incomplete bony healing at 8 weeks. 3. The 2mm group showed weak osteogenesis and fibrous union or nonunion at 8 weeks. From these results, it could be stated that distraction rate of 0.5mm per day was most useful in rat's tibia. The rate of 1mm showed delayed bony healing and needed more consolidation period. Distraction osteogenesis is a excellent clinical method for regenerating local bone deficiencies in limbs and craniofacial area. The more studies needed for the higher animals and human about distraction rates and other biomechanical factors on the basis of this study.

  • PDF

Feature Based Techniques for a Driver's Distraction Detection using Supervised Learning Algorithms based on Fixed Monocular Video Camera

  • Ali, Syed Farooq;Hassan, Malik Tahir
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권8호
    • /
    • pp.3820-3841
    • /
    • 2018
  • Most of the accidents occur due to drowsiness while driving, avoiding road signs and due to driver's distraction. Driver's distraction depends on various factors which include talking with passengers while driving, mood disorder, nervousness, anger, over-excitement, anxiety, loud music, illness, fatigue and different driver's head rotations due to change in yaw, pitch and roll angle. The contribution of this paper is two-fold. Firstly, a data set is generated for conducting different experiments on driver's distraction. Secondly, novel approaches are presented that use features based on facial points; especially the features computed using motion vectors and interpolation to detect a special type of driver's distraction, i.e., driver's head rotation due to change in yaw angle. These facial points are detected by Active Shape Model (ASM) and Boosted Regression with Markov Networks (BoRMaN). Various types of classifiers are trained and tested on different frames to decide about a driver's distraction. These approaches are also scale invariant. The results show that the approach that uses the novel ideas of motion vectors and interpolation outperforms other approaches in detection of driver's head rotation. We are able to achieve a percentage accuracy of 98.45 using Neural Network.

신연 골형성술에 있어서의 분자생물학적 최신 지견 (CURRENT REVIEW OF MOLECULAR BIOLOGY IN DISTRACTION OSTEOGENESIS)

  • 지유진;송현철;김여갑;김진;김창현
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권6호
    • /
    • pp.456-463
    • /
    • 2002
  • Distraction osteogenesis is a well-established clinical treatment for limb length discrepancy and skeletal deformities. Appropriate mechanical tension-stress is believed not to break the callus but rather to stimulate osteogenesis. In contrast to fracture healing, the mode of bone formation in distraction osteogenesis is primarily intramembranous ossification. Although the biomechanical, histological, and ultrastructural changes associated with distraction osteogenesis have been widely described, the basic biology of the process is still not well known. Moreover, the molecular mechanisms in distraction osteogenesis remain largely unclear. Recent studies have implicated the growth factor cascade is likely to play an important role in distraction. And current reserch suggested that mechanical tension-stress modulates cell shape and phenotype, and stimulates the expression of the mRNA for bone matrix proteins. This article presents the hypotheses and current research that have furthered knowledge of the molecular biology that govern distraction osteogenesis. The gene regulation of growth factors and extracellular matrix proteins during distraction osteogenesis are discussed in this article. It is believed that understanding the biomolecular mechanisms that mediate distraction osteogenesis may guide the development of targeted strategies designed to improve distraction osteogenesis and accelerate bone healing.

하악골 신연술 후 생성된 신생골의 조직학적 및 면역화학적 소견 (THE HISTOLOGICAL AND IMMUNOHISTOCHEMICAL FINDINGS OF THE NEWLY FORMED HUMAN BONE AFTER DISTRACTION OSTEOGENESIS)

  • 윤경인;박재억
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제23권3호
    • /
    • pp.258-262
    • /
    • 2001
  • Distraction osteogenesis(DO) can be performed in the bony defect associated with trauma, anomaly, and various kinds of disease. The gap generated by DO is filled with growing callus : during the period of distraction, the osteogenesis is continued. However, there have been few reports about expression pattern of growth factors in newly formed bone during the consolidation periods. We performed DO in the mandibular defect case and studied the expressed pattern of growth factors. Its pattern was compared to that of the same patient. BMP-2 and -4 were strongly expressed in the DO site. Particularly, BMP-4 was not expressed in the normal mature bone, but expressed in new bone in DO. However, there was no difference in the FGF-7 expression between the sites. Therefore, strong expression of BMP-4 are related to new bone formation in DO and they may not be related to the normal homeostasis in human bone. Though FGF-7 is related to the growth of keratinocyte, it may have minimal role in the DO and normal mature bone.

  • PDF

역 L 형 절골술과 Liou 신연기를 이용한 넓은 치조열의 교정 (Correction of a Wide Alveolar Cleft with Reverse L osteotomy and Liou Alveolar Distractor)

  • 이명철;유대현;박병윤;권순만
    • Archives of Plastic Surgery
    • /
    • 제36권4호
    • /
    • pp.445-449
    • /
    • 2009
  • Purpose: A successful surgical treatment for a wide alveolar cleft with bone graft is difficult to achieve due to several factors such as the limitation of gingivoperiosteal flap, the presence of large scar tissues, and the poor blood circulation. To overcome these problems, alveolar distraction osteogenesis using Liou alveolar distraction device was applied. We analyzed the consequences of this surgical treatment. Method: Between 2006 January and 2007 August, we have conducted analysis on the methods and consequences of Liou alveolar distraction osteogenesis for 6 patients. The age of patients was 12 years and 6 months in average. The follow up period was 19 months in average. The Reverse L osteotomy followed by the placement of the Liou alveolar distraction device was performed. After serial distraction, the distractor was removed after 5 months of the process of osteogenesis, and the result was analyzed using the computed tomography and the x-ray films of the alveolar bone and the teeth. Results: The alveolar cleft with 12.5 mm in average width was filled with 8.5 mm of newly formed bone tissue in average width after 5 months of osteogenesis. Among the 6 cases, 5 required the additional bone graft and 1 case only required the gingivoperioplasty. The newly formed bone tissues did not show any signs of bone resorption. However, a considerable degree of teeth displacement was shown. Conclusion: For the alveolar cleft too wide to be reconstructed by a general bone graft, it is strongly recommended to perform the reverse L osteotomy of the cleft side with Liou alveolar distraction device to initiate the alveolar osteogenesis. However, the migrated teeth showed some degree of relapse, thus, the orthodontic treatment is essential following the distraction osteogenesis treatment.

Risk Factors of Allogenous Bone Graft Collapse in Two-Level Anterior Cervical Discectomy and Fusion

  • Woo, Joon-Bum;Son, Dong-Wuk;Lee, Su-Hun;Lee, Jun-Seok;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.450-457
    • /
    • 2019
  • Objective : Anterior cervical discectomy and fusion (ACDF) is commonly used surgical procedure for cervical degenerative disease. Among the various intervertebral spacers, the use of allografts is increasing due to its advantages such as no harvest site complications and low rate of subsidence. Although subsidence is a rare complication, graft collapse is often observed in the follow-up period. Graft collapse is defined as a significant graft height loss without subsidence, which can lead to clinical deterioration due to foraminal re-stenosis or segmental kyphosis. However, studies about the collapse of allografts are very limited. In this study, we evaluated risk factors associated with graft collapse. Methods : We retrospectively reviewed 33 patients who underwent two level ACDF with anterior plating using allogenous bone graft from January 2013 to June 2017. Various factors related to cervical sagittal alignment were measured preoperatively (PRE), postoperatively (POST), and last follow-up. The collapse was defined as the ratio of decrement from POST disc height to follow-up disc height. We also defined significant collapses as disc heights that were decreased by 30% or more after surgery. The intraoperative distraction was defined as the ratio of increment from PRE disc height to POST disc height. Results : The subsidence rate was 4.5% and graft collapse rate was 28.8%. The pseudarthrosis rate was 16.7% and there was no association between pseudarthrosis and graft collapse. Among the collapse-related risk factors, pre-operative segmental angle (p=0.047) and intra-operative distraction (p=0.003) were significantly related to allograft collapse. The cut-off value of intraoperative distraction ${\geq}37.3%$ was significantly associated with collapse (p=0.009; odds ratio, 4.622; 95% confidence interval, 1.470-14.531). The average time of events were as follows: collapse, $5.8{\pm}5.7months$; subsidence, $0.99{\pm}0.50months$; and instrument failure, $9.13{\pm}0.50months$. Conclusion : We experienced a higher frequency rate of collapse than subsidence in ACDF using an allograft. Of the various preoperative factors, intra-operative distraction was the most predictable factor of the allograft collapse. This was especially true when the intraoperative distraction was more than 37%, in which case the occurrence of graft collapse increased 4.6 times. We also found that instrument failure occurs only after the allograft collapse.