• Title/Summary/Keyword: Distance-estimation

Search Result 1,196, Processing Time 0.03 seconds

A Study on the Transport Mode Choice for Asian Highway No.6 Route (아시안하이웨이 6번 노선의 국제여객 교통수단선택에 관한 연구)

  • Lee, Back Jin;Lee, Se Hong;Lee, Yun Seok;Lee, Deok Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.875-886
    • /
    • 2015
  • By promoting the international transportation and the improvement of advanced exchange between South and North Korea, the Asian Highway plan was expected to make considerable economical effects in the North-East Asian region. This study focuses on a part of AH6 route (i.e., South Korea-North Korea-China-Far East Russia) and aims to analyze the behavioral change of international passenger transport around the Korean Peninsula by assuming the non-existent North Korea land transport network connectivity. The study was performed using two main methods. First, a stated preference survey was performed to derive the actual modal share of each travel mode. Second, a disaggregate analysis was performed to develop possible mode-choice models for international passenger travel and find out the suitable choice. Based on the results of the model estimation, it is found that over 90% of the international passenger transport would be converted to land transport (rail+highway). In addition, international railroad modal share rate would be increased from 62.8% to 66.1% and international bus would be decreased from 29.6% to 21.9% as the distance lengthened (903km~1,631km).

Stereoscopic Depth from 3D Contents with Various Disparity (화면 시차로부터 지각되는 3D 컨텐츠의 입체시 깊이)

  • Kham, Keetaek
    • Journal of Broadcast Engineering
    • /
    • v.21 no.1
    • /
    • pp.76-86
    • /
    • 2016
  • This study was investigated whether the perceived depth was changed depending on the measurement methods. In the method of direct comparison, virtual object with one of the various binocular disparities was presented in the frontal space with LEDs which were used for depth estimation for a binocular stimulus, while in the method of indirect comparison, visual object was presented in the frontal space but the LEDs were placed rightward at the angle of 45 degree from the mid-sagittal line. In these experimental setup, the depth of binocular stimulus was directly matched that of LED in direct comparison condition. In indirect comparison condition, however, observer estimated the depth of binocular stimulus, turned one's head rightward to the array of LEDs and turned on the LED which was supposed to be the same depth as binocular stimulus. Additionally, it was investigated whether the perceived depth was different depending on observer's stereo acuity. The results showed that perceived depths measured in the direct comparison were more similar to the depth predicted from geometry than those in the indirect comparison, and that the perceived depths from observers with high stereo acuity were similar to the predicted depth from geometry those from observers with low stereo acuity. These results indicated that stereoscopic depths of the binocular stimuli would vivid and compelling when binocular stimuli was simultaneously presented with real objects in the same visual space, like a mixed reality.

Study on the Estimation of Safety Zone and the Movement of Ground at the Inter-Crossing Tunnel (교차터널에서의 지반거동 및 안전영역평가에 관한 연구)

  • Kim, Woo-Sung;Yoo, Dong-Uk;Lee, Sang-Eun
    • Tunnel and Underground Space
    • /
    • v.18 no.6
    • /
    • pp.491-502
    • /
    • 2008
  • A certain range of the original ground around the tunnel should be preserved to ensure structural safety of the tunnel when other structures are made around the tunnel, and thus this range is defined as safety zone of the tunnel. The main points to ensure the stability of an existing tunnel when constructing a new tunnel in an inter-crossing area are distance between two tunnels, size of the new tunnel, excavation method for the new tunnel, ground condition around the tunnel, and lining type of the existing tunnel etc. When the new tunnel is excavated above the existing tunnel, the existing tunnel is likely to suffer deformation at a crown zone, damage of arching effect, and live load of the new tunnel etc. On the other hand, when the new tunnel is excavated below the existing tunnel, the existing tunnel is likely to be damaged due to settlement. This study has been made on the behavior of the existing tunnel by means of model test and numerical analysis when the new tunnel is excavated below the existing tunnel. Safety zone of the tunnel was estimated by the results of strength/stress ratio obtained from numerical analysis, and the movement of ground was estimated by the model test. The results of earth pressure, ground displacements, and convergence of the tunnel obtained from model test were compared with those of numerical analysis, and show a similar trend.

Comparison between the Road-based and the Parcel-based Address Coordinates for Urban Air Pollution Estimation - A Case Study of Yeongdeungpo-gu, Seoul, Korea - (도심대기오염추정을 위한 도로명주소좌표와 지번주소좌표의 비교 - 서울 영등포 지역의 사례연구 -)

  • Park, Jinwoo;Choi, Jinmu;Hong, Seong-Yun
    • Journal of Cadastre & Land InformatiX
    • /
    • v.46 no.2
    • /
    • pp.169-181
    • /
    • 2016
  • The address system in Korea was changed to the road-based system in 2014, but the current address coordinates are still largely based on the old, parcel-based system. Compared to the parcel-based address system that defines the center of a parcel as its coordinates, the road-based system locates the coordinates at a certain distance away from the road on which the parcel fronts. The difference in coordinates between these two systems is small, but it can be crucial for micro-level modelling. In order to assess the impact of the discrepancy between the two address systems, this study measured the degree of air pollution exposure at two different locations, the road-based address coordinates and the parcel-based address coordinates, for each of 252 buildings in Yeongdeungpo-gu, Seoul. The air pollution values were estimated using a microscopic air pollution dispersion model, CALINE4, and t-tests and F-tests were conducted to evaluate statistical significance on the observed difference. The results showed a considerable difference in the level of air pollution exposure between the two address systems, suggesting that the on-going use of the parcel-based address coordinates could cause potentially significant errors in micro-level analysis.

Estimation of Drought Rainfall by Regional Frequency Analysis Using L and LH-Moments (II) - On the method of LH-moments - (L 및 LH-모멘트법과 지역빈도분석에 의한 가뭄우량의 추정 (II)- LH-모멘트법을 중심으로 -)

  • Lee, Soon-Hyuk;Yoon , Seong-Soo;Maeng , Sung-Jin;Ryoo , Kyong-Sik;Joo , Ho-Kil;Park , Jin-Seon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.5
    • /
    • pp.27-39
    • /
    • 2004
  • In the first part of this study, five homogeneous regions in view of topographical and geographically homogeneous aspects except Jeju and Ulreung islands in Korea were accomplished by K-means clustering method. A total of 57 rain gauges were used for the regional frequency analysis with minimum rainfall series for the consecutive durations. Generalized Extreme Value distribution was confirmed as an optimal one among applied distributions. Drought rainfalls following the return periods were estimated by at-site and regional frequency analysis using L-moments method. It was confirmed that the design drought rainfalls estimated by the regional frequency analysis were shown to be more appropriate than those by the at-site frequency analysis. In the second part of this study, LH-moment ratio diagram and the Kolmogorov-Smirnov test on the Gumbel (GUM), Generalized Extreme Value (GEV), Generalized Logistic (GLO) and Generalized Pareto (GPA) distributions were accomplished to get optimal probability distribution. Design drought rainfalls were estimated by both at-site and regional frequency analysis using LH-moments and GEV distribution, which was confirmed as an optimal one among applied distributions. Design rainfalls were estimated by at-site and regional frequency analysis using LH-moments, the observed and simulated data resulted from Monte Carlotechniques. Design drought rainfalls derived by regional frequency analysis using L1, L2, L3 and L4-moments (LH-moments) method have shown higher reliability than those of at-site frequency analysis in view of RRMSE (Relative Root-Mean-Square Error), RBIAS (Relative Bias) and RR (Relative Reduction) for the estimated design drought rainfalls. Relative efficiency were calculated for the judgment of relative merits and demerits for the design drought rainfalls derived by regional frequency analysis using L-moments and L1, L2, L3 and L4-moments applied in the first report and second report of this study, respectively. Consequently, design drought rainfalls derived by regional frequency analysis using L-moments were shown as more reliable than those using LH-moments. Finally, design drought rainfalls for the classified five homogeneous regions following the various consecutive durations were derived by regional frequency analysis using L-moments, which was confirmed as a more reliable method through this study. Maps for the design drought rainfalls for the classified five homogeneous regions following the various consecutive durations were accomplished by the method of inverse distance weight and Arc-View, which is one of GIS techniques.

Source Estimation and Concentration Levels of PCBs in Ambient Air of an Industrial Area (공단지역 대기 중 PCBs의 오염농도 및 발생원 추정)

  • Kim, Kyoung-Soo;Song, Byung-Joo;Park, Seok-Un;Kim, Jong-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.385-389
    • /
    • 2005
  • To understand the pollution level by polychlorinated biphenyls (PCBs) in ambient air of industrial area, PCBs concentrations were measured at Sihwa and Banwol industrial region, Korea. The concentrations of total PCB and WHO-TEQ ranged from 2,080 to $5820\;pg/m^3$ (median value is 2,760) and from 0.19 to $1.01\;pgTEQ/m^3$ (median value is 0.42), respectively. In terms of homologues composition the fraction of highly chlorinated biphenyls(from hexa-CB to deca-CB) were higher than the air samples of other regions such as jeonju and yokohama area. The cluster analysis was conducted to study the relation between the air samples and sources such as incinerator flue gases and Aroclor samples. The isomer fractions in the homologue were used as input variables. Based on the results, the industrial ambient air samples were divided from source samples with long Euclidian distance. This suggest that the ambient air samples of Sihwa and Banwol were not on the influence of Aroclor and incinerators. Therefore, further investigation on systematical air monitoring will be required to estimate the sources of PCBs in the above industrial areas.

Design of Low-complexity FFT Processor for Multi-mode Radar Signal Processing (멀티모드 레이다 신호처리를 위한 저복잡도 FFT 프로세서 설계)

  • Park, Yerim;Jung, Yongchul;Jung, Yunho
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.2
    • /
    • pp.85-91
    • /
    • 2020
  • Recently, a multi-mode radar system was designed for efficient operation of unmanned aerial vehicles (UAVs) in various environments, which has the advantage of being able to integrate and utilize methods of the pulse Doppler (PD) radar and the frequency modulated continuous wave (FMCW) radar. For the range detection part of the multi-mode radar signal processor (RSP), the hardware structure using the FFT processor and the IFFT processor is required to be designed in a way that improves efficiency on the area side. In addition, given the radar application environment that requires a variety of distance resolutions, FFT processors need to support variable-length operations. In this paper, the FFT processor and IFFT processor in multi-mode RSP range estimation are designed and proposed as hardware for a single FFT processor that supports variable length operation of 16-1024 points. The proposed FFT processor designed in hardware description language (HDL) and can be implemented with 7,452 logic elements and 5,116 registers.

Improved Bi-directional Symmetric Prediction Encoding Method for Enhanced Coding Efficiency of B Slices (B 슬라이스의 압축 효율 향상을 위한 개선된 양방향 대칭 예측 부호화 방법)

  • Jung, Bong-Soo;Won, Kwan-Hyun;Jeon, Byeung-Woo
    • Journal of Broadcast Engineering
    • /
    • v.14 no.1
    • /
    • pp.59-69
    • /
    • 2009
  • A bi-directional symmetric prediction technique has been developed to improve coding efficiency of B-slice and to reduce the computational complexity required to estimate two motion vectors. On the contrary to the conventional bi-directional mode which encodes both forward and backward motion vectors, it only encodes a single forward motion vector, and the missing backward motion vector is derived in a symmetric way from the forward motion vector using temporal distance between forward/backward reference frames to and from the current B picture. Since the backward motion vector is derived from the forward motion vector, it can halve the computational complexity for motion estimation, and also reduces motion vector data to encode. This technique always derives the backward motion vector from the forward motion vector, however, there are cases when the forward motion vector is better to be derived from the backward motion vector especially in scene changes. In this paper, we generalize the idea of the symmetric coding with forward motion vector coding, and propose a new symmetric coding with backward motion vector coding and adaptive selection between the conventional symmetric mode and the proposed symmetric mode based on rate-distortion optimization.

Health Status and Health Care Utilization in a Rural Area, Nepal (네팔 도서지역 주민들의 상병상태 및 의료이용양상)

  • Lee, Myung-Ken;Kim, Myung-Ho;Lee, Myung-Sun;Park, Kyoung-Ok
    • Journal of agricultural medicine and community health
    • /
    • v.21 no.2
    • /
    • pp.231-241
    • /
    • 1996
  • The estimation of medical care status and the planning of health service program should be done according to each community resident's socio-medical background and public health service. In this point, it is most necessary to be set the exact and new socio-economic statistics data in Nepal, one of the worst countries in national health status. We surveyed 668 house, 3,425 residents in Dolka area, Nepal from January 25th to February 1st, 1995. 1. In personal characteristics, the ratio of men and women was similar, the person who were below 19 years old were 28.1% and the single were 52.4%. The illeterate person were 50.3% and the lower group in economic status which had been estimated by interviewers were 46.9%. 2. In sanitational characteristics, the person who used stream water or rainwater to drink were 42.2% and the person who always boiled water to drink were only 8.3%. The person who had not toilet in their house were 67.3% and the lower group in sanitational status which had been estimated by interviewers were 61.8%. 3. The prevalence rate of illness during the last one month were 8.6% and the chronic were 26.1% and the acute were 72.5%. The distribution of sickness symptom were headache, fever and joint pain in order and the person who took no medical treatment among the sick were 37.0%. The patterns of medical utilization were public health center, hospital and pharmacy in order. 4. Illness prevalence was significantly related to sex, age, merital status and educational experience. The residents who were women, 40 years old or more, married and had not educational experience were apt to take illness. 5. Medical utilization was significantly related to educational experience, job, distance from home to medical facilities and economic status. The person who had educational experience, were officer workers or merchants, lived near by medical facilities and had higher economic status took medical treatment very well.

  • PDF

The Estimation of Tree Form Index for Major Canopy Species in the Natural Deciduous Forest (천연활엽수림(天然闊葉樹林) 주요(主要) 상층(上層) 임관(林冠) 수종(樹種)의 임목(林木) 형질(形質) 지수(指數) 추정(推定))

  • Kim, Ji Hong;Yang, Hee Moon
    • Journal of Forest and Environmental Science
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 1999
  • Noticing the intrinsic growing habit variations of hardwood species which is indigenous to the natural deciduous forest, eighteen tree species in overstory were selected for comparative evaluating tree form so as to develop the tree form index (TFI). Selected six tree form attributes were arbitrarily divided four assessment criteria and given appropriate scores. Eighteen tree species were undergone corresponding scores, converted to percentage base, and estimated TFI by the summation of the six scoring values. Cluster analysis was carried out to review which attribute would have been shared among species based on dissimilarity of scores for each pair of species in $18{\times}6$ data matrix. The result showed that Populus davidiana had the highest TFI value of 80.8 and Carpinus cordata had the lowest TFI va1ue of 46.3. The species which received more than 70 of TFI are Populus davidiana, Betula costata, Fraxinus mandshurica, and Ulmus davidiana var. japonica, characterized by the advantage of straight and longer bole, the narrower crown, and the thinner branch. On the contrary, such species as Sorbus alnifolia. Prunus sargentii, Acer mandshuricum, Juglans mandshurica, and Carpinus cordata received less than 60 of TFI, characterized by the disadvantage of the crooked or forked stem. the wider or deeper crown. and the thicker branch. In the dendrogram produced by cluster analysis, arbitrary value of Euclidean distance 10 divided eighteen species into four distinctive groups. and the typical characteristics of each group were discussed.

  • PDF