• 제목/요약/키워드: Distance measurement system

검색결과 961건 처리시간 0.066초

복부초음파를 이용한 상완혈(上脘穴)-췌장 수직거리 측정시스템의 재현성 반복성 평가실험-A Pilot Study- (Gage R&R Study on Abdominal Sonography for Measuring Distance from Sangwan (CV13) to Pancreas - A Pilot Study -)

  • 남동현
    • 대한한의진단학회지
    • /
    • 제14권2호
    • /
    • pp.75-84
    • /
    • 2010
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from Sangwan (CV13) to pancreas. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from CV13 to pancreas with a ultrasound device three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from CV13 to pancreas was 6.29. So we concluded that repeatability and reproducibility of the ultrasound device system for measuring distance from CV13 to pancreas was acceptable.

영상처리기반 자동주차 시스템을 위한 레이저 포인터를 이용한 스테레오 비전 거리측정 알고리즘 (Stereo vision distance measurement algorithm using Laser point for Image processing based Automatic car-parking system)

  • 김윤호;임명섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.373-376
    • /
    • 2007
  • As a part of automatic car parking, this paper have devised the distance measurement algorism using stereo vision system which measure between object and parking lot. In this simulation, laser pointer is used for detecting edge of designated object and real distance is measured by searching the position of laser pointer and measuring the distance. Which are 1 / 1.5 / 2 / 2.5 / 3m and adjusted correction had applied in order for use in car parking system.

  • PDF

영상감시 시스템에서 평행식 스테레오 카메라를 이용한 다중 이동물체의 거리측정 (Distance Measurement of the Multi Moving Objects using Parallel Stereo Camera in the Video Monitoring System)

  • 김수인;이재수;손영우
    • 조명전기설비학회논문지
    • /
    • 제18권1호
    • /
    • pp.137-145
    • /
    • 2004
  • 본 논문은 평행식 스테레오 영상감시 시스템을 이용하여 3차원 공간에서 다중 이동물체를 검출하고, 카메라에서 이동 물체까지의 거리를 측정하는 알고리즘을 제안하였다. 스테레오 영상감시 시스템의 좌, 우측 영상을 입력을 받아 적응형 임계값과 화소귀납 알고리즘(PRA, pixel recursive algorithm)을 사용하여 다중 이동물체 영역을 추출하였다. 그리고 각각의 물체영역을 윈도우 마스크로 검출하고, 다중 이동물체 각각의 위치좌표와 스테레오 시차를 구하였다. 이 시차와 스테레오 비전 시스템의 특성 및 삼각 함수를 이용하여 다중 이동물체의 거리를 측정하였다. 실험결과 거리측정 오차도 7.28%이내에 존재하였으며, 따라서 제안한 알고리즘을 이용하여 시스템을 구현할 경우 스테레오 방범 시스템, 자율 이동로봇 및 스테레오 원격제어 시스템 등에 응용될 수 있을 것이다.

Measurement of Distance and Velocity of Moving Objects using Single Camera Pseudo-Stereo Images

  • Lee, Jae-Soo;Kim, Soo-In;Choi, In-Ho
    • 조명전기설비학회논문지
    • /
    • 제21권9호
    • /
    • pp.32-38
    • /
    • 2007
  • In this study, a new algorithm for measuring the velocity and distance from a camera to a moving object by using pseudo-stereo images obtained from a single camera with a stereo adapter is proposed. The proposed system is similar to a parallel visual stereo system using a two-camera system, but because this system can obtain pseudo-stereo images form a single camera, it has advantages not only in the aspect of cost but also in stereo conformity by arrangement and the calibration of the left and right stereo cameras upon image processing.

초음파센서 배열 시스템에서 물체의 각도 추론에 관한 연구 (A Study on the Object Angle Inference in a Sonar Sensor Array System)

  • 나승유;박민상
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.271-274
    • /
    • 1998
  • Ultrasonic sensors are becoming indispensable components in every sector of automation equipments due to many advantages. But the main purposes of the noncontact sensing device are rather narrowly confined within object detection and distance measurement. To widen the realm of the applications to object recognition, ultrasonic sensors need to improve the recognition resolution to a certain amount. To resolve the problem of spatial resolution restriction, an increased number of the sensors in the forms of a linear array or 2-dimensional array of the sensor has been used. Also better resolution has been obtained by shifting the array in several steps using mechanical actuators. For an object recognition using ultrasonic sensors, measurements of distance, shift, oblique angle in certain ranges should be obtained. But a little attention has been paid to the measurement of angles. In this paper we propose a practical method for an object angular value detection in addition to distance measurement in ultrasonic sensor array system with little additional hardware burden. Using the established measurement look-up table for the variations of distance, shift, angle and transmitter voltages for each sensor characteristics, a set of different return echo signals for adjacent receivers are processed to provide enhanced angular value reading for an object.

  • PDF

습식방식의 초음파 유량계 시스템 개발에 관한 연구 (A Study on the Wet Type Ultrasonic Flow-meter System Development)

  • 이응석;권오훈;노명환;이형석
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1638-1644
    • /
    • 2005
  • This paper suggests fur the study on a fluid velocity measuring system using ultrasonic transducer. In general, the time difference method to measure the distance between transducers has been known. In this paper, the practical technology for manufacturing ultrasonic flow meter system is studied using the time difference method. The ultrasonic transducer was designed and manufactured. The transmission and receiving algorithm for ultrasonic signal was studied. The ultrasonic flow measuring system was experimented in laboratory using a water reservoir for verifying the distance measuring accuracy. Finally, it was tested in flow calibration laboratory for the velocity measuring performance. The system, designed in this study, showed 0.3 mm resolution in distance measurement. For precise flow measurement, a high speed triggering algorithm is required for ultrasonic signal receiving.

자동 고장 판별 및 거리 측정 기능을 갖는 휴대용 케이블 고장 검출 장치 개발 (Development of Portable Cable Fault Detection System with Automatic Fault Distinction and Distance Measurement)

  • 김재진;전정채
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1774-1779
    • /
    • 2016
  • This paper proposes a portable cable fault detection system with automatic fault distinction and distance measurement using time-frequency correlation and reference signal elimination method and automatic fault classification algorithm in order to have more accurate fault determination and location detection than conventional time domain refelectometry (TDR) system despite increased signal attenuation due to the long distance to cable fault location. The performance of the developed system method was validated via an experiment in the test field constructed for the standardized performance test of power cable fault location equipments. The performance evaluation showed that accuracy of the developed system is less than 1.34%. Also, an error of automatic fault type and location by detection of phase and peak value through elimination of the reference signal and normalization of correlation coefficient and automatic fault classification algorithm not occurred.

Capturing Distance Parameters Using a Laser Sensor in a Stereoscopic 3D Camera Rig System

  • Chung, Wan-Young;Ilham, Julian;Kim, Jong-Jin
    • 센서학회지
    • /
    • 제22권6호
    • /
    • pp.387-392
    • /
    • 2013
  • Camera rigs for shooting 3D video are classified as manual, motorized, or fully automatic. Even in an automatic camera rig, the process of Stereoscopic 3D (S3D) video capture is very complex and time-consuming. One of the key time-consuming operations is capturing the distance parameters, which are near distance, far distance, and convergence distance. Traditionally these distances are measured by tape measure or triangular indirect measurement methods. These two methods consume a long time for every scene in shot. In our study, a compact laser distance sensing system with long range distance sensitivity is developed. The system is small enough to be installed on top of a camera and the measuring accuracy is within 2% even at a range of 50 m. The shooting time of an automatic camera rig equipped with the laser distance sensing system can be reduced significantly to less than a minute.

거리 측정 시스템의 정밀도 향상을 위한 카운터 회로의 설계 (Design of Counter Circuit for Improving Precision in Distance Measuring System)

  • 최진호
    • 한국정보통신학회논문지
    • /
    • 제24권7호
    • /
    • pp.885-890
    • /
    • 2020
  • 거리측정 시스템에서 사용되는 시간-디지털 변환회로는 시작신호와 멈춤신호 사이의 시간 간격을 이용하여 거리를 측정한다. 응답속도를 고려한 시간 간격은 일반적으로 카운터 회로를 이용하여 디지털 정보로 변환한다. 그러므로 정밀도 향상을 위해서는 높은 주파수의 클록 신호가 요구되며, 미세 거리의 측정을 위해서도 높은 주파수의 클록 신호가 필요하다. 본 논문에서는 동일한 주파수를 사용하면서도 거리 측정의 정밀도를 높이기 위한 카운터 회로를 설계하였다. 회로의 설계는 0.18㎛ CMOS 공정을 이용하였으며, 설계된 회로의 동작은 HSPICE 시뮬레이션을 통하여 확인하였다. 시뮬레이션 결과 일반적인 카운터 회로를 사용한 경우에 비해 4배의 향상된 정밀도를 얻을 수 있었다.

맹인 안내용 모빌로보트의 설계 (A Design of a Mobile Robot for Blind Guidance)

  • 유상열;이응혁
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.33-42
    • /
    • 1985
  • In this paper, a mobile robot is designed for the blind guidance. This system is composed of an Ultrasonic Ranging Vnit, PWM Vnit, Optical Encoder Vnit. Specilly we adapted Distance Comparison Measurement Method (DCMM) in order to compensate for the error resulted from atmospheric conditions, and PWM unit for the vehicle control and Optical encoder unit for the correct locomotion control. This system is processed, using MCS-85 microcomputer, much of information on surrounding conduitions in real time. We rotated ultrasonic sensor for many sifted data acquisition and used tone generator for the Man-Machine Communication. As a result, the measurement error of the distance is about 1cm, the distance measurement could be detected 0.2m to 6m. The locomotion speed is 0.4m/sec and we examined its practical use.

  • PDF