• Title/Summary/Keyword: Distance dynamic stereoacuity

Search Result 5, Processing Time 0.02 seconds

Comparison and Correlation between Distance Static Stereoacuity and Dynamic Stereoacuity (원거리 정적 입체시와 동적 입체시의 평가 및 상관관계)

  • Kim, Young-Cheong;Kim, Sang-Hyun;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.385-390
    • /
    • 2015
  • Purpose: This study evaluated the static stereoacuity by Distance Randot Stereotest (STEREO OPTICAL. Co., Inc. USA) and the dynamic stereoacuity by three-rods test (iNT, Korea). Criterion and correlation of stereoacuity between both tests and usefulness of two stereotest methods were also evaluated. Methods: For normal adults of 109 (male 61, female 48), mean age of 20.88 (19-32 years) years old, static stereoacuity by using Distance Randot Stereotest at 3 m distance, dynamic stereoacuity by using three-rods test at 2.5 m distance were measured. Results: The mean of distance static stereoacuity was $155.77{\pm}133.11sec$ of arc and the mean of error distance dynamic stereoacuity $11.13{\pm}9.69mm$. With equivalent-conversion stereoacuity of $23.44{\pm}20.96sec$ of arc, there was statistically significant differences (p=0.00) between two dynamic stereoacuity, but correlation was relatively low (${\rho}=0.226$). In the case of dynamic stereoacuity, separated to normal range by criterion of the error distance 20 mm, it showed the error distance of less than 20 mm in 97 subjects(89%) whose average of error distance and conversion mean dynamic stereoacuity were $8.43{\pm}5.10mm$ and $17.68{\pm}10.67sec$ of arc. repectively. The error distance of was equivalent-conversion dynamic stereoacuity 40.99 sec of arc (PD 62 mm basis) was 20 mm. Conclusions: The results of lower correlation between static and dynamic stereoacuity suggest that seterotest should be applied separately to different functions. The results of this study also suggest that Distance Randot Stereotest can be applied to static stereoacuity excluding monocular cues. Three-rods test can be applied to dynamic stereoacuity containing the response of the eye-hand coordination in the daily life of natural vision condition, including the monocular cues. These different approaches canprovide a criterion of the two stereoacuity and parallel use of the two tests would be useful. For dynamic stereoacuity by three-rods test, error distance 20 mm in a normal range of adults can be used as a criteria to get statistical meaning of the results.

Assessment of Dynamic Stereoacuity of Adults in their 20s' with Howard-Dolman Test (하워드-돌먼 입체검사를 이용한 20대 성인의 동적 입체시 평가)

  • Shim, Hyun-Suk;Choi, Sun-Mi;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.1
    • /
    • pp.61-66
    • /
    • 2015
  • Purpose: In this study, dynamic stereoacuity of 20s' adults were measured by using the Howard-Dolman test(H-D TEST, Bernell, U.S.A), and compared of male and female. And the correlation between dynamic stereoacuity and PD(pupillary distance), and between dynamic stereoacuity and anisometropia caused by difference in the spherical refractive power of the left and right eyes were analyzed. Methods: The mean age of $22.68{\pm}0.50$(20~29)years old, 20s' 63 adults (30 male, 33 female) were conducted for this experiments. After the full correction of subject's refractive error, dynamic stereoacuity was measured 5 times for 1 subject at 2.5 m distance using the H-D test. at 2.5 distance. Results: The mean of dynamic stereoacuity was $28.44{\pm}25.03$ sec of arc for total subjects, $28.23{\pm}23.34$ sec of arc for male, and $28.63{\pm}26.83$ sec of arc for female. In the dynamic stereoacuity classified by the range of inter-pupil distance (IPD), the dynamic stereoacuity was $33.87{\pm}18.53$ sec for the IPD being under 59.80 mm, $26.24{\pm}25.26$ sec of arc for 59.81~66.15 mm, $34.60{\pm}25.65$ sec of arc for over 66.15 mm. However, there were no significant differences between 3 groups (P=0.73, r=0.03). In dynamic stereoacuity classified by the refractive error difference between two eyes, dynamic stereoacuity was $26.81{\pm}24.86$ sec of arc for the under 1 D, $41.45{\pm}24.18$ sec of arc for over 1 D, and there was no significant difference between two groups (P=0.15, r=0.15). Conclusions: Dynamic stereacuity by the H-D test in 20s adults showed that there was no significant differences between male and female, and PD and anisometropia did not have a significant impact upon the dynamic stereoacuity.

Changes of Dynamic Stereoacuity Depending on Distance between Rods and Rod Thickness in Three Rods Test (세막대 검사에서 막대 간 거리와 막대두께 차이에 의한 동적입체시력의 변화)

  • Han, Kyung-Do;Lee, Min-Jae;Kim, Sang-Yeob;Moon, Byeong-Yeon;Yu, Dong-Sik;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.253-257
    • /
    • 2016
  • Purpose: To determine whether the distance between objects and the size of object are factors to be able to affect dynamic stereoacuity. Methods: Subjects were 37 adults (26 males and 11 females) with an average age of $23.89{\pm}1.76$. Refractive error was fully corrected for all subjects and each visual acuity of them was over 0.9. Three rods test was performed for measurement of stereoacuity. The viewing angles from left rod to right rod were set $5^{\circ}$, $10^{\circ}$, and $15^{\circ}$ and the rod thickness used 7 mm, 14 mm, and 21 mm, respectively. Stereoacuity was repeatedly measured three times in each test condition at 2.5 m distance, and reported the average value of them. Results: When rod thickness was 7 mm or 14 mm, dynamic stereoacuity decreased as the viewing angle increased, and they were significantly decreased (p<0.01) at viewing angles of $10^{\circ}$ and $15^{\circ}$ as compared with that of at $5^{\circ}$, respectively. When rod thickness was 21 mm, dynamic stereoacuity decreased as the viewing angle increased, especially, that of at $15^{\circ}$ decreased significantly (p<0.01) as compared with that of at $5^{\circ}$. The dynamic stereoacuity depending on the rod thickness have an increasing tendency as the rod thickness increased. Conclusions: The viewing angle between objects and the size of viewing object were factors that affect to dynamic stereoacuity.

The Comparasion of the Dynamic Stereoacuity with Two-Rods Test and Three-Rods Test (이간계와 삼간계를 이용한 동적 입체시의 비교)

  • Shim, Hyun-Suk;Kim, Sang-Moon;Kim, Sang-Hyun;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.377-384
    • /
    • 2015
  • Purpose: On this study, we measured and compared the dynamic stereoacuity by two-rods test (Howard-Dolman Test) and three-rods test. And we analyzed the correlation between PD and refractive error with dynamic stereoacuity. Methods: Dynamic stereoacuity of two-rods test and three-rods test at 2.5 m distance for 93 adults 93 (50 males, 43 females), mean age of $21.27{\pm}2.32$ (19~32) years old, were measured 5 times for two tests. Results: The mean of dynamic stereoacuity measured by two-rods test and three-rods test were $29.91{\pm}23.03sec$ of arc and $23.75{\pm}21.65sec$ of arc for total subjects, respectively. The mean of male and female were $36{\pm}22.38sec$ of arc and $22.28{\pm}23.79$, respectively. Three-rods test showed better dynamic stereoacuity than two-rods test, but there was no statistically significant difference (p>0.05). For the average standard deviation of PD between 60.63 mm~66.19 mm, dynamic stereoacuity fo two-rod test and three-rod test were $31.48{\pm}24.87sec$ of arc and $31.48{\pm}24.87sec$ of arc, respectively. The results showed statistically significant difference (p<0.05), but the relationship between dynamic stereoacuity and PD was not great. Comparison between two tests on the basis of refractive error, dynamic stereoacuity by three-rods test was better than by two-rods test with no significant difference between both tests (p>0.05) and there was little correlation between refractive error and two dynamic stereoacuity. Conclusions: Three-rods test showing lower stereoacuity than two-rods tests could measure the lower minimum threshold of dynamic stereoacuity. It was found that both tests can be applied to dynamic stereoacuity test as a standard test, and PD and refractive error was found that little effect upon the dynamic stereoacuity. PD and refractive error was found that little effect upon the dynamic stereoacuity.

The Comparative Assessment of the KVA and Dynamic Stereoacuity (동적시력(KVA)과 동적 입체시의 비교 평가)

  • Kim, Young-Cheong;Shim, Hyun-Suk;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.519-525
    • /
    • 2014
  • Purpose: On this study, we investigated the relationship between the kinetic visual acuity (KVA) and the dynamic stereoacuity and the effects of anisometropia with measuring KVA and the dynamic stereoacuity. Methods: For 63 adults (male 30, female 33), KVA and the dynamic stereoacuity were measured by using the kinetic visual acuity tester (KOWA AS-4A) and the Howard-Dolman test (H-D test) at distance 2.5 m after conducted full correction of subjects' refractive error respectly. Results: The means of KVA were $0.49{\pm}0.25$ for total subjects, $0.58{\pm}0.26$ for male, $0.40{\pm}0.22$ for female, and LogMAD (Log minimum angle of displacement) dynamic stereoacuities were $1.27{\pm}0.44$($28.44{\pm}25.03sec$ of arc) for total subjects, $1.28{\pm}0.44$($28.23{\pm}23.34sec$ of arc) for male, $1.27{\pm}0.45$($28.63{\pm}26.83sec$ of arc) for female. KVA showed a statistically significant difference between male and female (p=0.00), but dynamic stereoacuity was no significant difference (p=0.97). No significant correlation was present between KVA and dynamic stereoacuity (r=0.03). Also there were no significant differences in the dynamic stereoacuity of the three group which were classified according to the low, middle, high range of KVA (p=0.99). The anisometropia were less than 1 D and over 1 D when divided into two groups, KVA and dynamic stereoacuity showed no significant difference between each (p=0.11, p=0.99). There was no significant correlation between anisometropia and KVA (r=0.33), dynamic stereoacuity (r=0.18) but the correlation between KVA and anisometropia revealed more higer than between dynamic stereoacuity and anisometropia. Conculsions: The KVA for adults showed a significant difference between male and female and male was higher than female for KVA. The dynamic stereoacuity due to the KVA, the KVA and dynamic stereoacuity due to anisometropia were not significant differences between each and also were not great correlations.