• Title/Summary/Keyword: Distance AC/A

Search Result 186, Processing Time 0.033 seconds

The Influence of Combustion Flame on AC and DC Flashover Characteristics in the Air-Gaps Simulated Overhead Power Lines (가공(架空)전력선을 모의(模擬)한 공기 갭에서 교류 및 직류 섬락특성에 미치는 연소화염의 영향)

  • Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.152-159
    • /
    • 2010
  • A combustion flame under the overhead power lines may be caused by breakdown disturbances in power systems. In this study, experiments were conducted for the purpose of investigating the reduction in insulation strength caused by combustion flame and the shape changes of the flame, and flashover characteristics and extinction phenomena of the flame in the simulated conditions of overhead power lines were examined under the application of a.c. and d.c. high-voltages. As the results of the experimental investigation, it is demonstrated that flame can remarkably reduce breakdown voltages of the air-gap in shorter range of the gap distance. As the gap distance increases, flame was quenched, before the flashover, by corona wind generated from the needle electrodes.

Research on Comparison of Individual and Connecting Grounding Electrode for Potential Rise Distribution (개별 접지전극과 연접된 접지전극의 전위상승 분포 비교 연구)

  • Gil, Hyoung-Jun;Choi, Chung-Seog;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.57-62
    • /
    • 2008
  • This paper deals with a comparison of individual and connecting grounding electrode for potential rise. When a test current flowed through grounding electrode, potential rise was measured and analyzed for grounding method using a electrolytic tank in real time. In order to analyze the potential rise of grounding systems, a hemispherical water tank experimental apparatus was studied. Potential rise was measured and analyzed regarding the grounding method and distance by using this apparatus. The apparatus was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured by the horizontal moving probe of the potentiometer. The grounding electrodes were designed and fabricated with ground rods on a scale of one-eightieth. Potential rises of individual grounding electrode were higher than those of connecting grounding electrode. The distributions of surface potential are dependent on the distance from grounding electrode.

An Investigation on Surface Flashover Characteristics of FRP in Several Insulation Gases for the Spacer of Cryogenic Bushing

  • Hwang, Jae-Sang;Shin, Woo-Ju;Seong, Jae-Kyu;Lee, Jong-Geon;Lee, Bang-Wook
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.4
    • /
    • pp.20-23
    • /
    • 2012
  • Superconducting equipment has been actively investigated for securing the environment and energy technology (ET) in various parts of the world. Despite these movements, a high voltage cryogenic bushing, which plays an important role of interconnection between the electric power systems and superconducting devices, has not been fully developed due to severe insulation requirements. A gas insulated cryogenic bushing has been investigated as one of our projects since 2010. As a basic step to obtain the design parameters for cryogenic bushing, we focused on the surface flashover characteristics of glass fiber reinforced plastic (FRP) in several insulation gases. For the surface flashover tests, several insulation gases including $SF_6$, $CF_4$ and $N_2$ gas were prepared. Various length of FRP specimens were fabricated in order to obtain the fundamental data for creepage distance of FRP. The first specimen group was from 2 mm to 10 mm with 2 mm intervals and the second specimen group was from 20 mm to 100 mm with 20 mm intervals. And the gas pressure was varied from 1 bar to 4 bar. An AC overvoltage test and a lightning impulse test were performed. Then the experimental results of surface flashover were obtained and analyzed. Based on these results, it would be possible to design the optimum creepage distance of FRP in a cryogenic bushing.

A Study on Distance Relay of Transmission UPFC Using Artificial Neural Network (신경회로망을 이용한 UPFC가 연계된 송전선로의 거리계전기에 관한 연구)

  • Lee, Jun-Kyong;Park, Jeong-Ho;Lee, Seung-Hyuk;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.37-44
    • /
    • 2004
  • This paper represents a new approach for the protective relay of power transmission lines using a Artificial Neural Network(ANN). A different fault m transmission lines need to be detected classified and located accurately and cleared as fast as possible. However, The protection range of the distance relay is always designed on the basis of fixed settings, and unfortunately these approach do not have the ability to adapt dynamically to the system operating condition. ANN is suitable for the adaptive relaying and the detection of complex faults. The backpropagation algerian based multi-layer protection is utilized for the teaming process. It allows to make control to various protection functions. As expected, the simulation result demonstrate that this approach is useful and satisfactory.

Effect of Tire Contact Stresses on Tensile Strains in the Surface of Thin Asphalt Pavement (접지압력이 앎은 아스팔트포장 표층 인장 변형률에 미치는 영향 분석)

  • Park, Dae-Wook;Park, Joon-Kyu
    • International Journal of Highway Engineering
    • /
    • v.10 no.2
    • /
    • pp.47-55
    • /
    • 2008
  • In this paper, comparisons are presented on the predicted tensile strains which can affect the fatigue life of a thin asphalt concrete (AC) pavement near the surface of pavement from three-dimensional (3D) finite element (FE) using 3D measured tire contact stresses of a radial tire and a bias ply tire and a layered linear elastic program (BISAR). The objective was to analyze the stress distributions for a 11R22.5 radial tire and a $10{\times}20$ bias ply tire, and to compare the predicted tensile strains at the top and bottom of AC surface using different analysis methods. The results show that the stress distributions of two tires are similar but the 11R22.5 radial tire has much higher vertical contact stress than that of the $10{\times}20$ bias ply tire. The predicted tensile strains at the bottom of AC layer under the center of tire showed higher value by BM (BISAR with the measured contact area) method, which the measured tire contact area is used in a layered elastic program, while the tensile strain at the top of AC surface of 3.5cm offset distance from tire edge by 3D FE analysis showed the highest values among three analysis methods.

  • PDF

Extremely high efficiency wireless power transfer system for EV charger (전기자동차 충전을 위한 고효율 무선전력전송 시스템)

  • Moon, SangCheol;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.155-156
    • /
    • 2015
  • This paper proposes a high efficiency wireless power transfer system with an asymmetric 4-coil resonator. It presents a theoretical analysis, an optimal design method, and experimental results. In the proposed asymmetric 4-coil system, the primary side consists of a source coil and two transmitter coils which are called intermediate coils, and in the secondary side, a load coil serves as a receiver coil. In the primary side, two intermediate coils boost the apparent coupling coefficient at around the operating frequency. Because of this double boosting effect, the system with an asymmetric 4-coil resonator has a higher efficiency than the conventional symmetric 4-coil system. The prototype operates at 90 kHz ofswitching frequency and has 200 mm of the power transmission distance between the primary side and the secondary side. An AC-DC overall system efficiency of 96.56% has been achieved at 3.3 kW of output power.

  • PDF

Relationships between Reading Ability and Binocular Vision (읽기능력과 양안시기능의 관계성)

  • Kim, Young Ji;Lee, Min-A;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.171-177
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the relationships between reading ability and binocular functions, based on self tests through surveys. The possibility of the reading ability tests used in this study as a tool on the determination about vision efficiency was also evaluated. Methods: Through reading ability tests about 138 university students, 72 students (52.2%) of them were first selected. Through self tests about dyslexia and light sensitivity, 38 students (52.7%) of the first selected students were secondly selected, whose extents are more than 3. Binocular tests were carried out about three groups (high, middle, low) of these secondly selected students. Tests about NPCs, distance and near phoria, amplitude of accommodation, fusional vergence, AC/A ratio, accommodative facility, and vergence facility were performed as binocular tests. Results: NPCs were closest to eyes at high groups. Fusional vergence, AC/A ratio, accommodative facility, and vergence facility of high group showed higher than other groups. The phoria at middle group showed higher than other groups. Conclusions: We found that reading ability and some of binocular functions were closely related. Therefore, vision training, associated with insufficiencies of binocular functions, is expected to improve reading ability.

HILS of the Braking System of a High Speed Train (고속전철 제동시스템의 HILS)

  • Hwang, Won-Ju;Kang, Chul-Goo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.5
    • /
    • pp.432-437
    • /
    • 2001
  • Korea High Speed Train(KHST) is supposed to run up 350km/h, in which the braking system has a crucial role for the safety of the train. In the design st데 of the braking system, its very hard to ac-quire information data for design guidelines. A HILS(Hardware-In-the-Loop Simulation) system can be used to get design data which could simulate the braking system of the real train in real-time. In this paper, cars are modelled including car dynamics, brake blending algorithms, pneumatic actuator dynamics, the models of each braking devices, adhesive coefficients, and soon. Real-time braking time, distance, and other design parameters are simulated using a DSP board and C language which shows the validity of the proposed method.

  • PDF

A New Concept of Magnetic Cable for Safe Mobile Power Delivery

  • Lee, Woo-Young;Huh, Jin;Choi, Su-Yong;Rim, Chun-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.410-412
    • /
    • 2011
  • Magnetic cables that can deliver high frequency AC electric power safely for flammable or sensitive workplaces preventing from arcs and electric shocks are firstly proposed in this paper. To deliver the power for a long distance, several new magnetic cable structures which drastically reduce the parallel leakage flux by appropriate magnetic shield between the magnetic cables are suggested; hence, the output power can be improved more than ten times. The proposed magnetic cables are fully analyzed and verified by simulations and experiments with good agreement. The output power and efficiency for a prototype magnetic cable of 1.5m long and 1 cm gap between parallel cores were measured as 154W and 67 %, where the source current and frequency were 10 A and 20 kHz, respectively.

  • PDF

The Laser Range Finder for the Mobile Robot Navigation using a Lock-in Amplifier

  • Yoon, Hee-Sun;Shin, Myung-Kwan;Park, Kyi-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1423-1426
    • /
    • 2005
  • Map building is the most important thing for the mobile robots navigation. It requires specific vision system such as CCD camera, range finding system, and many other things. Laser range finder has highly collimated beams can be obtained easily, thus achieving lateral resolution. Laser Diode is used for a continuous laser source. The Automatic Current Control Circuit and the Bias-T is used for mix AC signal with DC bias. This signal is used for driving Laser Diode. The main idea of the calculating distance is detecting phase shift between reference signal and detected signal by photo detector. For the signal processing, the Lock-in amplifier system is addressed in this paper. We used a diffused reflected beam to detect phase shift in this system. But this beam is minuteness signal so it can be easily buried in nose. Lock-in amplifier is used to measure the amplitude and phase of signals which are buried in noise.

  • PDF