• Title/Summary/Keyword: Distal Effect

Search Result 360, Processing Time 0.162 seconds

A Finite Element Analysis of Stress on the Femoral Stem with Resorption of Proximal Medial Femur after Total Hip Replacement (대퇴골 근위부 골흡수가 인공 고관절 대퇴 stem에 미치는 응력에 관한 연구-FEM을 이용한 분석)

  • 김성곤
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.183-188
    • /
    • 1994
  • In clinical orthopaedics, bone resoption in the cortex is often seen post operatively on X-rays or bone densitometry after total hip replacement (THR) in the form of cortical osteoporosis or atropy. Stress shielding of bone occurs, when a load, normally carried by the bone alone, is shared with an implant as a result, the bone stresses are abnormal and with remodelling analysis this may cause extensive proximal bone resoption, possibly weakening the bone bed to the point of failure. The author made finite element models of the cemented and non-cemented type implanted femoral stem with bone resorption of the proximal medial femur and studied the feed back effect of the various degree of bone resoption to THR system by parametric analysis on the stress of the femoral stem and interface. The results of the present finite element analysis implied that the extent of proximal bone resorption has the effect of more increasing stress on the distal stem tip, cement mantle and interface in both type of femoral stem and this high distal stress possibly can cause the mechanical failure of loosening or failure after THR.

  • PDF

Effect of Titanium Prosthesis on Computed Tomography Measurements of Bone Mineral Density

  • Han, S.M.;Zude Feng
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.177-182
    • /
    • 1998
  • This study investigated the effects of a titanium prosthesis, malalignment, field of view, and distal flare of titanium prosthesis on computed tomography( CT) measurements of home mineral density. Eight femora and eight tibiae from fresh male cadavers were used. Fifteen pieces of cancellous bone from the proximal tibiae were milled into rectangular parallelepipeds. Parallelepipeds and femors were scanned with and without titanium prosthesis when centered in the gantry of the CT scanner and malaligned, respectively. Image data were then reconstructed with field of view of 10 and 30 cm. Bone mineral density(BMD) values were obtained from CT images using C-MED software. The effects of titanium prosthesis, malalignmetn, and field of view were investigated. When bone was centered in the gantry of the CT scanner, the mean relative difference of BMD measurements caused by a titanium prosthesis was less than 1% for both cortical and cancellous bone. Field of view had negligible effect on BMD measurements as well. Malalignment and distal flare of prosthesis, however, caused a significant difference in BMD measurements(p<0.0001). The titanium prosthesis did not interfere with malalignment combining the existence of a titnium prosthesis on BMD measurements was significant.

  • PDF

Distal Radius Osteosarcoma (원위 요골 골육종)

  • Song, Won-Seok;Won, Ho-Hyun;Lee, Jeong-Dong;Jeon, Dae-Geun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.2
    • /
    • pp.55-61
    • /
    • 2010
  • Purpose: We analyzed the clinical outcome of osteosarcoma developed in distal radius and the effect of delayed treatment on prognosis. Materials and Methods: Twelve patients with distal radius osteosarcoma were analysed. We categorized patients into two groups of standard treatment or non-standard treatment. The patients of standard treatment group are all stage IIB and non-standard treatment group includes five stage IIB and one stage III. Results: Five-year overall survival and disease-free survival rates of standard treatment group were 100% and 83%. Five-year overall survival rate of non-standard treatment group was 44%. Between two group, there are differences in age, tumor size, surgery type, symptom duration. Conclusion: Distal radius osteosarcoma have good prognosis than other extremity osteosarcoma. Survival rate of non-standard treatment group were lower than standard treatment group. Although the prognosis of non standard treatment group is poorer, the duration till death was longer than that of other sites with similar condition. Further multi-institutional study should be needed.

Effect of Suprabulge Clasp and Infrabulge Clasp on the Mobility of Abutment Teeth for Distal Extension Removable Partial Dentures (유리단 국소의치에서 Suprabulge Clasp와 Infrabulge Clasp가 지대치 동요에 미치는 영향에 관한 연구)

  • Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.39-45
    • /
    • 1981
  • Distal-extension removable partial dentures have long been implicated in the increase in mobility and the destruction of the supporting structures of the primary abutment teeth. Various clasping systems have traditionally been used to retain distal extension removable partial dentures, and other designs have been proposed to minimize torquing forces on the abutment teeth. Most recent studies investigating the effects of removable partial dentures on abutment teeth have been performed in it laboratory setting. Results obtained from in vitro research have given dentists insight into removable partial denture design, but laboratory test model cannot be constructed that simulates actual functional or parafunctiona1 movements and forces. The purpose of this study was to clinically evaluate the degree of tooth mobility produced by two clasping systems (suprabulge type and infrabulge type) used for distal extension removable partial dentures. Akers clasp and R.P.I. system were selected for the evaluation, and four patients required a distal extension removable partial denture on the mandibular arch were selected for participation in the study. Two partial dentures were constructed in the same condition expect the design of clasp. All abutments in the study were mandibular first or second premolars. Measurements of mobility were made with a research tool designed by $M\"{u}hlemann$. This instrument, periodontometer, measures tooth mobility in the mouth by means of a dial gauge accurated to 0.01mm when the tooth is stressed with a force meter. Lingual and buccal deflection of abutment tooth was measured using buccal and lingual pressure. The amount of force applied was 500gm. Tooth mobility tests were made at four key stages; 1. Before insertion of the first removable partial denture, baseline mobility was establsihed. 2. After wearing of the first prosthesis, measurement was made at weekly intervals for 4 weeks. 3. The removable partial denture was then taken from the patient, and tooth mobility was measured again at weekly intervals until the patient's established baseline mobility had returned. 4. The second prosthesis of different clasp design was worn for a month and evaluated in the same manner as the first. The sequence of placement of clasping system was alternated between patients. The following results were obtained from this study; 1. The mobility of abutment tooth increased during the initial stage of wear and returned to baseline mobility after removal of removable partial dentures. 2. The mobility of abutment tooth showed no difference between Akers clasp and I-bar clasp during the 4-week test period. 3. All teeth tested showed greater mobility toward the buccal than the lingual direction.

  • PDF

Effect of Dietary Fiber and Fat on Tumor Incidence and Cell Proliferation of Colonic Mucosa in DMH-Treated Rats (Dimethylhydrazine으로 처리한 쥐에서 식이섬유소와 지방종류가 대장의 종양발생율과 세포증식에 미치는 영향)

  • 최주선
    • Journal of Nutrition and Health
    • /
    • v.31 no.4
    • /
    • pp.697-707
    • /
    • 1998
  • This study was designed to observe the effect of dietary fiber and fat on colon tumor incidence and cell proliferation. Male Sqraue Dawley rats(n=225) at 7 weeks of age, were divided into 3 groups depending on the type of fat b(beef tallow, corn oil and DHA-rich fish oil) and each group was again divided into 3 groups depending on type of fiber(fiber-free, perctin and cellulose) . The experimental diet containing dietary fat at 15%(w/w) and fiber at 6%(w/w) levels was fed for 25 weeks. At the same time, each rats was intramuscularly injected with DMH two times a week for 6 weeks to geive total dose of 180mg/kg body weight. Cell proliferation was measured by in vivo incroporation of bromodeoxyuridine (BrdU) into DNA. Fish oil decreased the tumor incidence (9.67%) compared with beef talow (33.39%) and corn oil (21.21%). Tumor incidence was decreased in all groups that fed cellulose (11.67%) compared with those of fiber-free(21.74%) and pectic(19.70%). Most of tumors was distributed at the site of the distal colon. The rats fed both fish oil and cellulose significantly decreased th enumber of tumors and tumor incidence compared to other groups. Fish oil was more effective in preventing cell prolofieration by decreasing crypt length and labeling index(LI) compared with beef tallow(p<0.05). Cell proliferation in distal colon was more developed to the upper part of the crypt compared to proximal colon. Overall tumor incidence and cell proliferation were more affected by dietary fat. But the effect of dietary fiber was different depending on type of fat in the experimental diet. These results suggest that a DHA -rich fish oil may has more decisive effect in inhibiting the cell proliferation in colon.

  • PDF

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

The Effect of Complementary Access to Milk Replacer to Piglets on the Activity of Brush Border Enzymes in the Piglet Small Intestine

  • Wang, J.F.;Lundh, T.;Westrom, B.;Lindberg, J.E.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.11
    • /
    • pp.1617-1622
    • /
    • 2005
  • The activity of brush border enzymes (sucrase, lactase and maltase) in the piglet small intestine was evaluated as well as piglet performance during the weaning period in the present study. There were two treatment groups: Piglets of six litters were fed dry feed plus milk replacer (Group M) and of six litters fed dry pelleted feed (Group C). One piglet from each litter was sacrificed on day 3 before weaning, and day 3, 10 and 17 postweaning, respectively. Providing milk replacer caused an increased piglet live weight at weaning (p<0.001) and until termination of the experiment (p<0.001). A slightly higher (p<0.16) level of protein was measured in the jejunum of group M piglets as compared with group C piglets. Before weaning the activity of lactase was high in the jejunum of group C piglets. The activity of lactase in the jejunum was lowered in the jejunum of group C piglets and in distal jejunum of group M piglets during the postweaning period as compared with pre-weaning period (p<0.05). Lowered activity of lactase in the distal jejunum of piglets was found at day 10 and 17 postweaning, respectively. No treatment differences were found in the activity of lactase in the piglet jejunum. No treatment differences were seen in the activity of maltase and sucrase in the piglet jejunum also. However, weaning caused a higher activity of sucrase in the distal jejunum of group M piglets as compared with pre-weaning period. In conclusion, providing milk replacer to piglets caused an improved growth performance. Feeding milk replacer did not influence the activity of lactase, maltase and sucrase in the jejunum of piglets. Weaning resulted in a markedly lowered activity of lactase, while no dramatic changes in the activity of maltase took place during the period around weaning.

Analgesia of Electroacupuncture and Radio-Frequency Warm Needling in Acupoint Combination on Ankle Sprain in Rats (발목염좌에 배혈에 따른 전침과 고주파온침의 진통효과)

  • Yang, Seung-Bum;Kim, Min-Su;Kim, Jae-Hyo
    • Korean Journal of Acupuncture
    • /
    • v.35 no.1
    • /
    • pp.27-35
    • /
    • 2018
  • Objectives : The purpose of this study was to investigate the analgesic effect of electroacupuncture(EA) and radio-frequency warm needling(RFWN) stimulation in acupoint combination on ankle sprained pain in rats. Methods : The lateral ligaments of the Sprague-Dawley rats ankle were injured surgically resulting in sprain, of which was divided into EA, RFWN treatment groups and control group without treatment. The level of pain was measured through foot weight bearing force ratio followed by calculating pain relief. To stimulate proximal or distal area in ankle sprain, combination of proximal acupoints(GB34-GB39) and distal acupoints(GB39-GB42) from sprain area were applied, respectively, to either EA or RFWN stimulation. In addition, naltrexone or phentolamine was injected intraperitoneally before the stimulation to observe the pathway of analgesic effects. Results : In the proximal combination of GB34-GB39, EA and RFWN significantly increased pain relief compared to the control group (p<0.05). However, in distal combination with GB39-GB42, both EA and RFWN stimulation did not relieve pain due to ankle sprains. In the combination of GB34-GB39, the analgesia of EA was inhibited by blockade of the ${\alpha}$-adrenoceptor receptor. The analgesia of RFWN was inhibited by blockade of the ${\alpha}$-adrenoceptor receptor as well as ${\mu}$-opioid receptor. Conclusions : We observed that the proximal combination was effective in relieving pain when the treatment by acupoint combination was applied to the ankle sprain pain. Also, it was confirmed that this analgesia was also related to the pathways of ${\mu}$-opioid receptors and/or ${\alpha}$-adrenoceptors.

The Effects of Balloon-Guide Catheters on Outcomes after Mechanical Thrombectomy in Acute Ischemic Strokes : A Meta-Analysis

  • Ahn, Jun Hyong;Cho, Steve S.;Kim, Sung-Eun;Kim, Heung Cheol;Jeon, Jin Pyeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.389-397
    • /
    • 2019
  • Objective : Mechanical thrombectomies with balloon-guide catheters (BGC) are thought to improve successful recanalization rates and to decrease the incidence of distal emboli compared to thrombectomies without BGC. We aimed to assess the effects of BGC on the outcomes of mechanical thrombectomy in acute ischemic strokes. Methods : Studies from PubMed, EMBASE, and the Cochrane library database from January 2010 to February 2018 were reviewed. Random effect model for meta-analysis was used. Analyses such as meta-regression and the "trim-and-fill" method were additionally carried out. Results : A total of seven articles involving 2223 patients were analyzed. Mechanical thrombectomy with BGC was associated with higher rates of successful recanalization (odds ratio [OR], 1.632; 95% confidence interval [CI], 1.293-2.059). BGC did not significantly decrease distal emboli, both before (OR, 0.404; 95% CI, 0.108-1.505) and after correcting for bias (adjusted OR, 1.165; 95% CI, 0.310-4.382). Good outcomes were observed more frequently in the BGC group (OR, 1.886; 95% CI, 1.564-2.273). Symptomatic intracranial hemorrhage and mortality did not differ significantly with BGC use. Conclusion : Our meta-analysis demonstrates that BGC enhance recanalization rates. However, BGC use did not decrease distal emboli after mechanical thrombectomies. This should be interpreted with caution due to possible publication bias and heterogeneity. Additional meta-analyses based on individual patient data are needed to clarify the role of BGC in mechanical thrombectomies.

Force changes associated with differential activation of en-masse retraction and/or intrusion with clear aligners

  • Zhu, Ye;Hu, Wei;Li, Shuo
    • The korean journal of orthodontics
    • /
    • v.51 no.1
    • /
    • pp.32-42
    • /
    • 2021
  • Objective: To investigate the three-dimensional forces created by clear aligners on mandibular teeth during differential activation with en-masse retraction and/or intrusion in vitro. Methods: Six sets of clear aligners were designed for differential en-masse retraction and/or intrusion procedures in a first premolar extraction model. Group A0 was a control group with no activation. Groups A1-5 underwent different degrees of retractions and/or intrusions. Each group consisted of 10 aligners. Aligner forces were measured on a multi-axis force/torque transducer measurement system in real-time. Results: In the en-masse retraction groups (A1 and A2), lingual and extrusive forces were observed on the incisors; the canines mainly received distal forces; intrusive forces were seen on the second premolars; and the molars received mesial forces. In the en-masse retraction and intrusion groups (A3, A4, and A5), incisors also received lingual and extrusive forces; canines received distal and intrusive forces; mesial and extrusive forces were seen on the second premolars; and the second molars received distal and intrusive forces. The vertical forces on the incisors did not differ significantly among groups A1, A3, and A5. However, the vertical forces on the second premolars reversed from intrusion in group A1 to extrusion in groups A3 and A5. Conclusions: With clear aligners, the "bowing effect" is seen during en-masse anterior teeth retraction and can be partially relieved by performing en-masse retraction accompanied by anterior teeth intrusion. Vertical control of incisors remained unsolved during en-masse retraction, even when intrusive activation was added to the anterior teeth.