DOI QR코드

DOI QR Code

Force changes associated with differential activation of en-masse retraction and/or intrusion with clear aligners

  • Zhu, Ye (Department of Orthodontics, Peking University School and Hospital of Stomatology) ;
  • Hu, Wei (Department of Orthodontics, Peking University School and Hospital of Stomatology) ;
  • Li, Shuo (Department of Orthodontics, Peking University School and Hospital of Stomatology)
  • Received : 2020.04.20
  • Accepted : 2020.10.01
  • Published : 2021.01.25

Abstract

Objective: To investigate the three-dimensional forces created by clear aligners on mandibular teeth during differential activation with en-masse retraction and/or intrusion in vitro. Methods: Six sets of clear aligners were designed for differential en-masse retraction and/or intrusion procedures in a first premolar extraction model. Group A0 was a control group with no activation. Groups A1-5 underwent different degrees of retractions and/or intrusions. Each group consisted of 10 aligners. Aligner forces were measured on a multi-axis force/torque transducer measurement system in real-time. Results: In the en-masse retraction groups (A1 and A2), lingual and extrusive forces were observed on the incisors; the canines mainly received distal forces; intrusive forces were seen on the second premolars; and the molars received mesial forces. In the en-masse retraction and intrusion groups (A3, A4, and A5), incisors also received lingual and extrusive forces; canines received distal and intrusive forces; mesial and extrusive forces were seen on the second premolars; and the second molars received distal and intrusive forces. The vertical forces on the incisors did not differ significantly among groups A1, A3, and A5. However, the vertical forces on the second premolars reversed from intrusion in group A1 to extrusion in groups A3 and A5. Conclusions: With clear aligners, the "bowing effect" is seen during en-masse anterior teeth retraction and can be partially relieved by performing en-masse retraction accompanied by anterior teeth intrusion. Vertical control of incisors remained unsolved during en-masse retraction, even when intrusive activation was added to the anterior teeth.

Keywords

References

  1. Turpin DL. Clinical trials needed to answer questions about Invisalign. Am J Orthod Dentofacial Orthop 2005;127:157-8. https://doi.org/10.1016/j.ajodo.2004.12.009
  2. Shin K. The Invisalign appliance could be an effective modality for treating overbite malocclusions within a mild to moderate range. J Evid Based Dent Pract 2017;17:278-80. https://doi.org/10.1016/j.jebdp.2017.06.010
  3. Bowman SJ, Celenza F, Sparaga J, Papadopoulos MA, Ojima K, Lin JC. Creative adjuncts for clear aligners, part 2: intrusion, rotation, and extrusion. J Clin Orthod 2015;49:162-72.
  4. Khosravi R, Cohanim B, Hujoel P, Daher S, Neal M, Liu W, et al. Management of overbite with the Invisalign appliance. Am J Orthod Dentofacial Orthop 2017;151:691-9.e2. https://doi.org/10.1016/j.ajodo.2016.09.022
  5. Bowman SJ, Celenza F, Sparaga J, Papadopoulos MA, Ojima K, Lin JC. Creative adjuncts for clear aligners, part 1: class II treatment. J Clin Orthod 2015;49:83-94.
  6. Houle JP, Piedade L, Todescan R Jr, Pinheiro FH. The predictability of transverse changes with Invisalign. Angle Orthod 2017;87:19-24. https://doi.org/10.2319/122115-875.1
  7. Bowman SJ, Celenza F, Sparaga J, Papadopoulos MA, Ojima K, Lin JC. Creative adjuncts for clear aligners, part 3: extraction and interdisciplinary treatment. J Clin Orthod 2015;49:249-62.
  8. Womack WR. Four-premolar extraction treatment with Invisalign. J Clin Orthod 2006;40:493-500.
  9. Baldwin DK, King G, Ramsay DS, Huang G, Bollen AM. Activation time and material stiffness of sequential removable orthodontic appliances. Part 3: premolar extraction patients. Am J Orthod Dentofacial Orthop 2008;133:837-45. https://doi.org/10.1016/j.ajodo.2006.06.025
  10. Giancotti A, Greco M, Mampieri G. Extraction treatment using Invisalign Technique. Prog Orthod 2006;7:32-43.
  11. Ojima K, Dan C, Nishiyama R, Ohtsuka S, Schupp W. Accelerated extraction treatment with Invisalign. J Clin Orthod 2014;48:487-99.
  12. Liu D, Yan B, Lei F, Li J, Wang X, Rong Q, et al. Different sliding mechanics in space closure of lingual orthodontics: a translational study by three-dimensional finite element method. Am J Transl Res 2019;11:120-30.
  13. Hahn W, Dathe H, Fialka-Fricke J, Fricke-Zech S, Zapf A, Kubein-Meesenburg D, et al. Influence of thermoplastic appliance thickness on the magnitude of force delivered to a maxillary central incisor during tipping. Am J Orthod Dentofacial Orthop 2009;136:12.e1-7; discussion 12-3. https://doi.org/10.1016/j.ajodo.2008.12.015
  14. Hahn W, Zapf A, Dathe H, Fialka-Fricke J, Fricke-Zech S, Gruber R, et al. Torquing an upper central incisor with aligners--acting forces and biomechanical principles. Eur J Orthod 2010;32:607-13. https://doi.org/10.1093/ejo/cjq007
  15. Kohda N, Iijima M, Muguruma T, Brantley WA, Ahluwalia KS, Mizoguchi I. Effects of mechanical properties of thermoplastic materials on the initial force of thermoplastic appliances. Angle Orthod 2013;83:476-83. https://doi.org/10.2319/052512-432.1
  16. Simon M, Keilig L, Schwarze J, Jung BA, Bourauel C. Forces and moments generated by removable thermoplastic aligners: incisor torque, premolar derotation, and molar distalization. Am J Orthod Dentofacial Orthop 2014;145:728-36. https://doi.org/10.1016/j.ajodo.2014.03.015
  17. Li X, Ren C, Wang Z, Zhao P, Wang H, Bai Y. Changes in force associated with the amount of aligner activation and lingual bodily movement of the maxillary central incisor. Korean J Orthod 2016;46:65-72. https://doi.org/10.4041/kjod.2016.46.2.65
  18. Liu Y, Hu W. Force changes associated with different intrusion strategies for deep-bite correction by clear aligners. Angle Orthod 2018;88:771-8. https://doi.org/10.2319/121717-864.1
  19. Krieger E, Seiferth J, Saric I, Jung BA, Wehrbein H. Accuracy of invisalign® treatments in the anterior tooth region. First results. J Orofac Orthop 2011;72:141-9. https://doi.org/10.1007/s00056-011-0017-4
  20. Gu J, Tang JS, Skulski B, Fields HW Jr, Beck FM, Firestone AR, et al. Evaluation of Invisalign treatment effectiveness and efficiency compared with conventional fixed appliances using the Peer Assessment Rating index. Am J Orthod Dentofacial Orthop 2017;151:259-66. https://doi.org/10.1016/j.ajodo.2016.06.041
  21. Kravitz ND, Kusnoto B, BeGole E, Obrez A, Agran B. How well does Invisalign work? A prospective clinical study evaluating the efficacy of tooth movement with Invisalign. Am J Orthod Dentofacial Orthop 2009;135:27-35. https://doi.org/10.1016/j.ajodo.2007.05.018
  22. Li W, Wang S, Zhang Y. The effectiveness of the Invisalign appliance in extraction cases using the the ABO model grading system: a multicenter randomized controlled trial. Int J Clin Exp Med 2014;8:8276-82.
  23. Bollen AM, Huang G, King G, Hujoel P, Ma T. Activation time and material stiffness of sequential removable orthodontic appliances. Part 1: ability to complete treatment. Am J Orthod Dentofacial Orthop 2003;124:496-501. https://doi.org/10.1016/S0889-5406(03)00576-6
  24. Caputo AA, Chaconas SJ, Hayashi RK. Photoelastic visualization of orthodontic forces during canine retraction. Am J Orthod 1974;65:250-9. https://doi.org/10.1016/S0002-9416(74)90330-3
  25. Knop L, Gandini LG Jr, Shintcovsk RL, Gandini MR. Scientific use of the finite element method in orthodontics. Dental Press J Orthod 2015;20:119-25. https://doi.org/10.1590/2176-9451.20.2.119-125.sar
  26. Barbagallo LJ, Shen G, Jones AS, Swain MV, Petocz P, Darendeliler MA. A novel pressure film approach for determining the force imparted by clear removable thermoplastic appliances. Ann Biomed Eng 2008;36:335-41. https://doi.org/10.1007/s10439-007-9424-5
  27. Vardimon AD, Robbins D, Brosh T. In-vivo von Mises strains during Invisalign treatment. Am J Orthod Dentofacial Orthop 2010;138:399-409. https://doi.org/10.1016/j.ajodo.2008.11.027
  28. Badawi H, Major P. Three-dimensional orthodontic force measurements. Am J Orthod Dentofacial Orthop 2010;137:299-300. https://doi.org/10.1016/j.ajodo.2010.01.006
  29. Ferguson JW. Lower incisor torque: the effects of rectangular archwires with a reverse curve of Spee. Br J Orthod 1990;17:311-5. https://doi.org/10.1179/bjo.17.4.311
  30. Pandis N, Polychronopoulou A, Sifakakis I, Makou M, Eliades T. Effects of levelling of the curve of Spee on the proclination of mandibular incisors and expansion of dental arches: a prospective clinical trial. Aust Orthod J 2010;26:61-5.
  31. Clements KM, Bollen AM, Huang G, King G, Hujoel P, Ma T. Activation time and material stiffness of sequential removable orthodontic appliances. Part 2: Dental improvements. Am J Orthod Dentofacial Orthop 2003;124:502-8. https://doi.org/10.1016/S0889-5406(03)00577-8
  32. Jacobson A. Contemporary orthodontics, 3rd edition. Am J Orthod Dentofacial Orthop 2000;117:PA1.