• 제목/요약/키워드: Display fatigue

검색결과 108건 처리시간 0.023초

Determination of The Optimal Binocular Parallax Inducing The Least 3D Visual Fatigue

  • Li, Hyung-Chul O.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1092-1094
    • /
    • 2009
  • The purpose of the research was to figure out the optimal binocular parallax inducing the least 3D visual fatigue. Subjective 3D visual fatigue was measured while the revolution depth and the average depth of an object were manipulated. The optimal binocular parallax was figured out by using data fitting method.

  • PDF

갈바노 스캐너와 DMD(Digital Micro-mirror Device)를 이용한 두부 고정형 다초점 디스플레이 시스템 (Head Fixed Type Multi-Focus Display System Using Galvano-Scanner and DMD(Digital Micro-Mirror Device))

  • 김동욱;권용무;김성규
    • 한국통신학회논문지
    • /
    • 제34권10B호
    • /
    • pp.1117-1123
    • /
    • 2009
  • DMD(Digital Micro-mirror Device)와 갈바노 스캐너를 이용한 두부 고정형 다초점 디스플레이 시스템은 초점조절이 가능하여 스테레오스코픽 디스플레이에서 발생하는 양안의 수렴작용과 단안의 초점조절 작용의 불일치에 의한 눈의 피로 문제를 해결할 수 있는 디스플레이 시스템이다. 이 시스템은 레이저 스캐닝 방법으로 각 시점에 대한 영상의 수렴점을 형성하여 관찰자 동공에 제공함으로 초점조절이 가능토록 한다. 본 논문에서는 이 다초점 디스플레이 시스템의 레이저 스캐닝 방법을 수학적으로 분석하였고, 이러한 분석에 기반 한 다초점 시스템을 제작하여 비디오카메라를 통하여 초점조절이 가능함을 보였고, 결과적으로 레이저 스캐닝 방법에 의한 다초점 시스템의 시점 형성원리가 검증되었다.

A Research on Curved Display Comparing to Flat Display Regarding Posture, Tilt Angle, Focusing Area and Satisfaction

  • Ahn, Sung Hee;Jin, Byungki;Kwon, Sanghyun;Yun, Myung Hwan
    • 대한인간공학회지
    • /
    • 제33권3호
    • /
    • pp.191-202
    • /
    • 2014
  • Objective: This study is conducted on the differences between flat and curved displays with respect to location of focused points, posture and satisfaction as well as preferred tilt angles. Background: In order to avoid physical and eye fatigue caused by misplayed sitting posture, many studies have asserted that the display requires appropriate location, size and tilt angle as well as curvature. However, most studies have focused on the work environment and the results are varied in the extent. Method: Eye height data in sitting posture were collected from 30 participants. Participants selected the most comfortable viewing angle within the range from $0^{\circ}$ to $12^{\circ}$ while watching videos for both curved and flat display. Then, physical and eye fatigue and overall satisfaction were subjectively evaluated. Lateral diagram describing viewing display condition was set and used to develop linear models for expecting the preferred tilt angle. Results: Due to sitting in the natural viewing posture rather than upright, the eye height is lowered to about 4.6 centimeters, on average, for both displays showing no significant differences. In contrast, preferred angles for the two displays are significantly different and this can be interpreted that curvature vary the points focused. Two linear models as functions of sitting eye height are developed to expect preferred tilt angle for each display. Based on the result of overall satisfaction evaluation, curved display is statistically better than flat display. Conclusion: The results show that flat and curved displays are significantly different expect for the viewing posture. However, reasons for preferring curved display are not accurately factorized and the linear models are limited in the experiment condition such as size of display, distance between display and viewer and other physical environmental factors. Further studies on curved displays under more various conditions are required. Application: This study can contribute to use of the curved display in various way.

게임 디스플레이 종류와 안경착용 여부에 따른 영상의 인지된 특성, 프레즌스 그리고 피로도의 차이 (Influence of Gaming Display and Wearing Glasses on Perceived Characteristics, Presence, and Fatigue)

  • 이현지;정동훈
    • 방송공학회논문지
    • /
    • 제17권6호
    • /
    • pp.1004-1013
    • /
    • 2012
  • 3D 영상 산업의 활성화와 함께 3D 영상이 적용됨으로써 유망한 산업 분야 중 하나가 게임이다. 2D에서 3D 그래픽으로 그리고 현재는 3D 입체영상으로 진화하면서 이용자에게 깊이감을 제공함으로써 더 큰 즐거움을 주고 있다. 그러나 우리나라 18세 이상 성인 중절반이 안경 또는 콘택트렌즈를 착용하고 있을 정도로 안경 착용자가 많은 환경에서 3D 영상을 즐기기 위해서 또 다른 안경인 3D 안경을 착용해야 하는 것은 큰 불편이 아닐 수 없다. 본 연구에서는 게임에서의 입체영상 및 안경 착용여부가 영상의 특성, 프레즌스 그리고 피로도 등에 어떠한 영향을 미치는지 알아보고자 했으며, 실험결과 디스플레이와 안경착용의 상호작용효과는 프레즌스 구성요소 중 시간관여에서 유의미하게 나타났다. 2D 영상에서는 안경 착용자가 높은 반면 3D 입체영상에서는 안경 비착용자가 높게 인지하였다. 그리고 인지된 특성과 피로도 변인에서는 영상 여부의 주효과에서만 유의미한 것으로 나타났다. 인지된 특성 구성요소 중 선명도에서는 3D 입체영상 보다 2D 영상의 화질이 좋다고 평가하였으며, 피로도는 2D 영상 보다는 3D 입체영상에서 높은 것으로 나타났다.

일부 금융직 근로자의 VDT 작업 실태와 피로도와의 관련성 (The Relationship of VDT Work Condition and Fatigue Severity in the Financial Office Workers)

  • 최순영;이병수
    • 대한안전경영과학회지
    • /
    • 제10권2호
    • /
    • pp.15-24
    • /
    • 2008
  • This study was to investigate the relationship of VDT(visual display terminal) work condition and fatigue severity in the financial office workers. Questionnaires were completed by 662 persons in VDT workers of Post Office from January to May 2006. Multidimensional Fatigue Scale(MFS) that was developed in Korea Occupational Safety &Health Agency to estimate the degree of fatigue was used for study. In results, 149 persons(22.5%) in VDT workers were felt low fatigue severity, 351 workers(53.0%) were middle, and 162 workers (24.5%) were high. So it was appeared that one in four VDT workers felt the high fatigue severity. And woman VDT workers felt more fatigue severity than man. Also, fatigue severity was increased with increasing work time. Our findings suggest that VDT workers in financial office need proper health program to prevent occupational fatigue and disease.

경견완장애의 피로자각증상과 관련요인 (Fatigue and related factors in cervicobrachial disorders)

  • 강점덕
    • 대한정형도수물리치료학회지
    • /
    • 제8권1호
    • /
    • pp.5-14
    • /
    • 2002
  • Objectives : In order to investigate industrial fatigue due to visual display terminal (VDT) work of post office. Methods : The questionnaire survey for subjective symptoms of fatigue was carried out on 39 post office clerks who had been engaged in VDT work for various length of work hours. The questionnaire comprised three groups of 10 items each, representing dullness and sleepiness, difficulty in concentration and bodily projection of fatigue. Results : The scores of dullness and sleepiness was 16.62, scores of concentration difficulty was 16.35, those of bodily fatigue was 16.23, and total scores was 49.21. Fatigue scores was significantly associated with age and work duration, VDT of work hours, ventilation, illumination, nosie. Conclusions : Data from this study support a statistically significant association between age and scores of dullness, scores of concentration difficulty, between work duration and scores of dullness, scores of bodily fatigue, between VDT of work hours and scores of bodily fatigue.

  • PDF

데스크탑용 CRT와 TFT-LCD의 시각 작업수행도 비교·평가 (A Comparative Evaluation on Visual Performance of CRT and TFT-LCD as Desktop Computer Displays)

  • 김상호;최경임
    • 대한인간공학회지
    • /
    • 제21권1호
    • /
    • pp.95-112
    • /
    • 2002
  • Two experiments were carried out to compare the suitability in visual tasks between cathode-ray tube (CRT) and thin film transistor-liquid crystal display (TFT-LCD). In the first experiment, the subjects were requested to detect pre-assigned target words or icons among distracters presented under time-invariant (static) image mode. The subjects' visual performance and fatigue were assessed while carrying out search tasks with dim and bright ambient light conditions. Significant interaction effects were found among displays, task types, and ambient light conditions. Due to visual fatigue, the subjects' accommodative power decreased in the end of task and the degradation was more significant for the CRT users and under bright ambient light. IN the second experiment, the subjects performed information processing task with time-varying road signs at a driving simulator to assess interaction effects between display types and changing speed of dynamic image. The perception time using TFT-TCD was shorter under slow image change while that of CRT was shorter rapid image change. Findings from this study suggest that, to improve visual task performance, users should carefully select their visual display type depending on the task to be performed.

A study on the ergonomic aspects of the proper luminance level of displays

  • Lee, Eunjung;Kim, Sangho;Park, HyeRyoung;Bae, Jaewoo;Lee, Seungbae;Kim, Haksun
    • Journal of Information Display
    • /
    • 제13권4호
    • /
    • pp.159-166
    • /
    • 2012
  • In this paper, a display's emotional image quality can be primarily determined by designing the proper luminance level. Though displays with high luminance are preferred, too much light emission from a display may cause glare or visual fatigue to viewers. To find out the proper luminance level based on various video contents, this study was conducted with an OLED display with a real-black level and a wide color gamut, and with an LCD display with a high luminance level, to set the glare threshold under various conditions. The optimum luminance levels according to the display's loading ratio were found, and the maximum luminance that did not cause a glare in the test is proposed.

HMD 형태의 초다시점 3차원 영상 표시 장치 (HMD Type SMV 3Ddisplay System)

  • 김성규
    • 방송공학회논문지
    • /
    • 제7권4호
    • /
    • pp.362-367
    • /
    • 2002
  • 평면 영상 표시 장치로부터 3차원 영상 표시 장치로의 이동에 있어 큰 걸림돌로 알려져 있는 눈의 피로 현상의 중요 요인으로 알려져 있는 양안의 수렴 작용과 각각의 눈의 초점 조절 불일치의 해결 가능성을 갖고 있는 초다시점 조건을 만족하는 HMD 형태의 3차원 영상 표시 장치를 제안하고, 실험적으로 단안의 초점 조절을 만족할 수 있음을 확인하였고, 그 실험 결과를 포함하였다.

Development of the HDTV Camera and Monitor for Stereoscopic 3D Display

  • Kim, Nam;Kwon, Ki-Chul;Park, Jae-Hyeung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1033-1036
    • /
    • 2008
  • In this paper, we describe the development of the polarized-light stereoscopic monitoring system based on full HDTV. The system consists of the stereoscopic camera part, image processing device for the stereoscopic image recording and stereoscopic display. The developed stereoscopic imaging display system reduces eyestrain and viewer fatigue.

  • PDF