• 제목/요약/키워드: Displacement sensitive

검색결과 220건 처리시간 0.024초

J-Integral Evaluation of Concrete Fracture Characteristics

  • Choi, Sin-Ho;Kye, Hae-Ju;Kim, Wha-Jung
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권3E호
    • /
    • pp.183-189
    • /
    • 2006
  • Many researchers have recently proposed various parameters, variables of models and experimental methods to evaluate fracture properties of concrete, and their developments allow us to analyze the non-linear and quasi-brittle fracture mechanisms. This paper presents a brief treatment of the fracture parameters. Additionally, three-point bending tests were conducted to compare J-integral($J_{Ic}$) with other parameters($K_{Ic},\;G_{Ic},\;and\;G_F$). The change in parameter values with respect to the width and notch length of concrete beam specimens was also considered. The load-displacement curves were used to measure the concrete fracture toughness experimentally. From the results of experiment, it was found that the value of $G_F\;and\;J_{Ic}$ decreased as the notch depth increased and that $G_F$ was less sensitive than $J_{Ic}$. Therefore, the former, $G_F$, is more appropriate in using it as the concrete fracture toughness parameter. The values of $G_F\;and\;J_{Ic}$ increased when the width of concrete specimens increasing from 75 mm to 150 mm. Thus, the effects of the specimen width should be considered in determining the fracture toughness of concrete.

Alternative numerical method for identification of flutter on free vibration

  • Chun, Nakhyun;Moon, Jiho;Lee, Hak-Eun
    • Wind and Structures
    • /
    • 제24권4호
    • /
    • pp.351-365
    • /
    • 2017
  • The minimization method is widely used to predict the dynamic characteristics of a system. Generally, data recorded by experiment (for example displacement) tends to contain noise, and the error in the properties of the system is proportional to the noise level (NL). In addition, the accuracy of the results depends on various factors such as the signal character, filtering method or cut off frequency. In particular, coupled terms in multimode systems show larger differences compared to the true value when measured in an environment with a high NL. The iterative least square (ILS) method was proposed to reduce these errors that occur under a high NL, and has been verified in previous research. However, the ILS method might be sensitive to the signal processing, including the determination of cutoff frequency. This paper focused on improving the accuracy of the ILS method, and proposed the modified ILS (MILS) method, which differs from the ILS method by the addition of a new calculation process based on correlation coefficients for each degree of freedom. Comparing the results of these systems with those of a numerical simulation revealed that both ILS and the proposed MILS method provided good prediction of the dynamic properties of the system under investigation (in this case, the damping ratio and damped frequency). Moreover, the proposed MILS method provided even better prediction results for the coupling terms of stiffness and damping coefficient matrix.

유체와 접한 판재에 박힌 압전센서의 유한요소 모델링 (Finite Element Modeling of a Piezoelectric Sensor Embedded in a Fluid-loaded Plate)

  • ;김재환
    • 소음진동
    • /
    • 제6권1호
    • /
    • pp.65-70
    • /
    • 1996
  • 유체와 접한 판재에 박힌 압전센서의 응답을 복합적인 유한요소 해석기법을 이용하여 모델링 하였다. 판재 구조물은 유체영역에서 전파되는 음향파에 의해서 가진된다. 구조물과 압전소자 주위의 유에부분을 유한요소기법을 써서 모델링였고 임의로 나눈 가상경계에서는 평면과 해를 적용하여 변위를 일치 시켰다. 또한, 이 경계에서 변위의 번분까지도 Penalty factor를 써서 일치 시켰으며 가상경계에서의 투명성을 증가시키기 위해서 유한요소의 각 절점에 회전자유도를 추가시켰다. 압전 센서 응답의 수치 결과가 구하여졌고 이것은 센서의 삽입효과가 적을 뿐만 아니라 구조물의 특성에 민감하다는 것이 밝혀졌다.

  • PDF

크랙을 가진 회전 외팔보의 동특성 해석 (Dynamic Behavior of Rotating Cantilever Beam with Crack)

  • 윤한익;손인수
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.620-628
    • /
    • 2005
  • In this paper, we studied about the dynamic behavior of a cracked rotating cantilever beam. The influences of a rotating angular velocity, the crack depth and the crack position on the dynamic behavior of a cracked cantilever beam have been studied by the numerical method. The equation of motion is derived by using the Lagrange's equation. The cracked cantilever beam is modeled by the Euler-Bernoulli beam theory. The crack is assumed to be in the first mode of fracture and to be always opened during the vibrations. The lateral tip-displacement and the axial tip-deflection of a rotating cantilever beam is more sensitive to the rotating angular velocity than the depth and position of crack. Totally, as the crack depth is increased, the natural frequency of a rotating cantilever beam is decreased in the first and second mode of vibration. When the crack depth is constant, the natural frequencies of a rotating cantilever beam are proportional to the rotating angular velocity in the each direction.

Grounding Line Change of Ronne Ice Shelf, West Antarctica, from 1996 to 2015 Observed by using DDInSAR

  • Han, Soojeong;Han, Hyangsun;Lee, Hoonyol
    • 대한원격탐사학회지
    • /
    • 제34권1호
    • /
    • pp.17-24
    • /
    • 2018
  • Grounding line of a glacier or ice shelf where ice bottom meets the ocean is sensitive to changes in the polar environment. Recent rapid changes of grounding lines have been observed especially in southwestern Antarctica due to global warming. In this study, ERS-1/2 and Sentinel-1A Synthetic Aperture Radar (SAR) image were interferometrically acquired in 1996 and 2015, respectively, to monitor the movement of the grounding line in the western part of Ronne Ice Shelf near the Antarctic peninsula. Double-Differential Interferometric SAR (DDInSAR) technique was applied to remove gravitational flow signal to detect grounding line from the interferometric phase due to the vertical displacement of the tide. The result showed that ERS-1/2 grounding lines are almost consistent with those from Rignot et al. (2011) which used the similar dataset, confirming the credibility of the data processing. The comparison of ERS-1/2 and Sentinle-1A DDInSAR images showed a grounding line retreat of $1.0{\pm}0.1km$ from 1996 to 2015. It is also proved that the grounding lines based on the 2004 MODIS Mosaic of Antarctica (MOA) images and digital elevation model searching for ice plain near coastal area (Scambos et al., 2017), is not accurate enough especially where there is a ice plain with no tidal motion.

An optimal regularization for structural parameter estimation from modal response

  • Pothisiri, Thanyawat
    • Structural Engineering and Mechanics
    • /
    • 제22권4호
    • /
    • pp.401-418
    • /
    • 2006
  • Solutions to the problems of structural parameter estimation from modal response using leastsquares minimization of force or displacement residuals are generally sensitive to noise in the response measurements. The sensitivity of the parameter estimates is governed by the physical characteristics of the structure and certain features of the noisy measurements. It has been shown that the regularization method can be used to reduce effects of the measurement noise on the estimation error through adding a regularization function to the parameter estimation objective function. In this paper, we adopt the regularization function as the Euclidean norm of the difference between the values of the currently estimated parameters and the a priori parameter estimates. The effect of the regularization function on the outcome of parameter estimation is determined by a regularization factor. Based on a singular value decomposition of the sensitivity matrix of the structural response, it is shown that the optimal regularization factor is obtained by using the maximum singular value of the sensitivity matrix. This selection exhibits the condition where the effect of the a priori estimates on the solutions to the parameter estimation problem is minimal. The performance of the proposed algorithm is investigated in comparison with certain algorithms selected from the literature by using a numerical example.

Evidence for Regulation of Interaction of Endogenous Protein Kinase C(Pkc) Substrates with Plasma Membrane by PKC Down-Regulation in K562 Cells

  • Kim, Young-Sook
    • Archives of Pharmacal Research
    • /
    • 제18권5호
    • /
    • pp.301-307
    • /
    • 1995
  • In the particulate fraction obtained from PKC-down regulated K562 cells by treatment for 24 h with 200nM TPA, phosphorylation of two proteins with molecular weight, 100 kDa and 23 kDa (designated p100 and p23, respectvely) was depleted and addition of exogenous purified PKC to this fraction failed to testore their phosphorylation. However, in the soluble fraction, all of phosphoproteins abolished by long-term treatment with TPA were restored by exogenously added PKC. Phosphorylation of two proteins was increased by short-term tretment (20 min), and diminished with the persistant exposure to TPA as well as at a concentration as low as 1nM. When K562 cells were treated with 1 nM and 200 nM TPA for 24 h, phosphorylation of p100 was restored with or without exogenous PKC on 2-3day and 6day after removal of treated TPA, respectively. Two-dimensional electrophoresis of phosphoproteins revealed that phosphorylated p100 (pl=5.9) and p66 species were completely absent from the particulate fraction of K562 cells treated with 200nM TPA for 24 h. These results suggest that the interaction of sensitive endogenous substrates, p100 and p23 with the plasma membrane might be regulated by PKC-down regulation without displacement to the cytosol and the interaction of p100 with the membrane might be reveersible.

  • PDF

New Application of 2-(4-N-Phenyl-3-thiosemicarbazone)-8-hydroxyquinoline as a Sensor for Relay Recognition of Cu2+ and Sulfide in Aqueous Solution

  • Tang, Lijun;Zhou, Pei;Huang, Zhenlong;Zhao, Jia;Cai, Mingjun
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권10호
    • /
    • pp.2905-2908
    • /
    • 2013
  • Fluorescent and colorimetric recognition properties of 2-(4-N-phenyl-3-thiosemicarbazone)-8-hydroxyquinoline (1) in buffered aqueous solution (1% DMSO, HEPES 20 mM, pH = 7.4) have been examined. Sensor 1 displays highly selective and sensitive recognition to $Cu^{2+}$ with fluorescence "ON-OFF" performance. The in situ formed 1-$Cu^{2+}$ complex exhibits an excellent selectivity toward sulfide ions with fluorescence "OFF-ON" behavior via $Cu^{2+}$ displacement approach. Thus, relay recognition of $Cu^{2+}$ and sulfide by a known molecule 1 has been achieved.

치은퇴축과 상아질 지각과민증의 빈도와 분포에 대한 임상적 연구 (Clinical study of gingival recession and dentine hyper-sensitivity)

  • 박기영;김성조;최점일;이주연
    • Journal of Periodontal and Implant Science
    • /
    • 제36권1호
    • /
    • pp.51-60
    • /
    • 2006
  • Gingival recession is clinically manifested by an apical displacement of the gingival tissue and dentin hypersensitivity is often used to describe a painful condition in which exposed dentin is unduly sensitive to intraoral stimuli. The objects of this study were primarily to investigate the prevalence and distribution of gingival recession and hypersensitivity and secondarily to determine whether a relationship exists between gingival recession and hypersensitivity. The study population was 195 patients (102 males, 93 females) who were attended the department of periodontology, Pusan National University Hospital. 189 patients exhibited gingival recession at least more than 1 tooth, the prevalence was 96.9%. The maxillary and mandibular first premolar and mandibular incisors had the highest prevalence. The majority of patients (139 patients, 71.3%) were diagnosed as having dentin hypersensitivity. Dentin hypersensitivity was determined to 3 seconds application of cold air to the exposed root surface after isolating the test tooth and was commonest in maxillary and mandibular first premolars and mandibular incisors. Relationship between recession and hypersensitivity was analyzed using chi-square test (p=0.05), significant relation (p=0.000) was existed. Gingival recession was more severe, the prevalence of hypersensitivity was higher.

글래스비드 정밀공급기구에 의한 바이오재료평가용 AFM프로브의 개발 (Development of A New Micro-fabricated AFM Probe for the Measurement of Biomaterials by using the Precision Glass Bead Supply Unit)

  • 권현규;임건
    • 한국기계가공학회지
    • /
    • 제13권6호
    • /
    • pp.30-36
    • /
    • 2014
  • Many different cells types have been found to be highly sensitive to mechanical force imposed by their surroundings. The cellular response to external mechanical forces has very important effects on numerous biological phenomena. In spite of its importance in biological processes, the cell adhesion force remains difficult to measure quantitatively at the cellular level. In this paper, to enhance quantitative measurements of cell adhesive interactions, a new attaching system and a method in which a glass bead can be attached to an AFM cantilever was designed and fabricated, and the degree of range displacement was controlled in the system. In an experiment, the movement of the stage in the attaching system and the attaching process were measured. The effectiveness of this system was confirmed as well in the experiment. In addition, through a commercial AFM system, the spring constant of the modified AFM probe could be measured.