• Title/Summary/Keyword: Dispersion equation

Search Result 330, Processing Time 0.027 seconds

A Study on the Safety Improvement in a Venting System from the HCl Release Accident of a Petrochemical Company (석유화학공장의 염화수소 누출사고를 통한 대기벤트 시스템의 안전성 향상 방안)

  • Ma, Byung-Chol;Lee, Keun-Won;Im, Ji-Pyo;Kim, Young-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.38-43
    • /
    • 2012
  • The purpose of this study is to carry out the consequence analysis of an accident related to the release of Hydrogen chloride occurred in a petrochemical company in Korea and suggest the measures to prevent similar accidents from happening again. The total amount released through the safety valve of HCl Column was calculated based on the rated capacity of the safety valve, the ideal gas equation and mechanical energy balance, respectively. As a result of the calculation, we found that the amount of HCl released through the safety valve was at least 76.8 kg. Also, we predicted the dispersion concentration at the position of the injured workers(more than 350 m away from the accident location) using simulation programs such as PHAST. The results of ALOHA and K-CARM are 304 ppm and 1,700 ppm respectively. However, PHAST calculation indicated that the concentration is less than l ppm. From these results, we can understand that workers were injured by HCl gas released from the safe valve and the concentration of gas might be less than 1 ppm. Also, it is important for toxic gases such as HCl to be vented safely to the atmosphere after scrubbing.

Estimation of Cadmium, Copper, Lead Mobility in Column Packed with Furnace Slag (제강슬래그로 충전된 컬럼에서의 카드뮴, 구리, 납의 이동성 평가)

  • Lee, Gwang-Hun;Chung, Jae-Shik;Nam, Kyoung-Phile;Park, Jun-Boum
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.4
    • /
    • pp.54-61
    • /
    • 2008
  • Permeable reactive barriers (PRBs) technology has been focused in contaminated groundwater remediation. It is necessary to select adequate reactive material according to characteristics of contaminant in groundwater. In this research, the reaction between reactive material and heavy metal contaminants was estimated through column test. Reactive material was slag, which has been produced in Gwangyang power plant, and heavy metal contaminants were cadmium, lead and copper. Column test was performed in the condition of 1) single and multi contaminated solution and 2) different initial concentration of cadmium. Retardation factor of cadmium is 3.94 in multi contamination. But that of copper is 40.3 in single and 25 in multi. The difference of retardation between cadmium and copper is due to affinity, resulted from the difference of electronegativity. In multi-contamination, copper effluent concentration was above initial copper concentration and at the same time lead effluent concentration was decreased. This phenomenon was considered that lead extract copper sorbed in slag and then lead was sorbed to the vacant sorption site instead. And as the initial concentration was increased, the retardation factor of cadmium became decreased.

Kinetic Analysis of Isothermal Pyrolysis of Korean Refuse Plastic Fuel for Application to Circulating Fluidized Bed Boiler (순환유동층 적용을 위한 국내 폐플라스틱 고형연료의 등온 열분해 분석)

  • Park, Kyoung-Il;Kim, Dong-Won;Lee, Tae-Hee;Lee, Jong-Min
    • Korean Chemical Engineering Research
    • /
    • v.51 no.6
    • /
    • pp.692-699
    • /
    • 2013
  • In this study, isothermal (350, 375, 400, 425, 450, 500, $850^{\circ}C$) experiments were carried out using a custom-made thermobalance to analyze the thermal decomposition properties of refuse plastic fuel (RPF), which is to be used as a cofiring fuel with a sub-bituminous coal at commercial circulating fluidized bed (CFB) boiler in Korea. In isothermal pyrolysis results, no change in the reaction model was observed in the temperature range of $375{\sim}450^{\circ}C$ and it was revealed that the first order chemical reaction (F1) is the most suitable among 12 reaction models. The activation energy shows similar results irrespective of application of reaction model in that the activation energy was 39.44 kcal/mol and 36.96 kcal/mol when using Arrhenius equation and iso-conversional method ($0.5{\leq}X{\leq}0.9$) respectively. Mean-while, the devolatilization time ($t_{dev}$) according to particle size (d) of RPF could be expressed as $t_{dev}=10.38d^{2.88}$ at $850^{\circ}C$, operation temperature of CFB and for even distribution and oxidation of RPF in CFB boiler, we found that the relationship of average dispersion distance (x) and particle size was $x{\leq}1.58d^{1.44}$.

Magneto-impedance and Magnetic Relaxation in Electrodeposited Cu/Ni80Fe20 Core/Shell Composite Wire (전기도금 된 Cu/Ni80Fe20 코어/쉘 복합 와이어에서 자기임피던스 및 자기완화)

  • Yoon, Seok Soo;Cho, Seong Eon;Kim, Dong Young
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.1
    • /
    • pp.10-15
    • /
    • 2015
  • The model for the magneto-impedance of composite wires composed of highly conductive nonmagnetic metal core and soft magnetic shell was derived based on the Maxwell's equations. The Cu($100{\mu}m$ diameter)/$Ni_{80}Fe_{20}$($15{\mu}m$ thickness) core/shell composite wire was fabricated by electrodeposition. The impedance spectra for the $Cu/Ni_{80}Fe_{20}$ core/shell composite wire were measured in the frequency range of 10 kHz~10 MHz under longitudinal dc magnetic field in 0 Oe~200 Oe. The spectra of complex permeability in circumferential direction were extracted from the impedance spectra by using the derived model. The extracted spectra of complex permeability showed relaxation-type dispersion which is well curve-fitted with Debye equation with single relaxation frequency. By analyzing the magnetic field dependence of the complex permeability spectra, it has been verified that the composite wire has magnetic anisotropy in longitudinal direction and the origin of the single relaxation process is the magnetization rotation in circumferential direction.

Simulating Bacterial Dispersion from Coastal Sewage Outfalls Using the QUICKEST Scheme (QUICKEST법을 사용한 연안해역에서 박테리아 확산의 수치모의)

  • Kang Yun Ho;Lee Moon Ock
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.2 no.2
    • /
    • pp.20-30
    • /
    • 1999
  • To improve water quality particularly for sea bathers along the Fylde coastal zone near Blackpool, North West England, waste water from a sewage outfall is studied using a mathematical model. The explicit second order accurate central scheme and the third order accurate QUICKEST scheme are used to represent the diffusion terms and the advection terms of the advective-diffusion equation, respectively. Hydrodynamic model is run for a coarse and fine grid, of 1km and 200m, respectively, obtaining good agreement with measured data. Water quality model is then used to predict faecal coliform levels in the region for four different scenarios, including discharges from: - (i) Fleetwood outfall, (ii)River Ribble for summer condition, (iii)River Ribble for winter condition, and (iv)combined sewer overflows for the Blackpool and Fleetwood communities. Main findings from the simulations are:- (i) Fleetwood outfall has a negligible impact on the beaches with respect to pathogen levels; (ii) Discharge from River Ribble for both summer and winter conditions is predicted in the range of coliform levels 10 -500 counts/100ml along the beach at Lytham St. Annes; and (iii) The CSO effluent discharges are predicted not to advect out into offshore by stronger tidal currents.

  • PDF

Surface Modification of Ba0.6Sr0.4TiO3 by Trimethylsilyl Chloride as a Silylation Agent (Trimethylsilyl Chloride를 Silylation Agent로 사용한 Ba0.6Sr0.4TiO3 나노입자의 표면개질 연구)

  • Lee, Chan;Han, Wooje;Park, Hyung-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.127-132
    • /
    • 2019
  • In this study, barium strontium titanate (BSTO) with high dielectric perovskite structure was synthesized by liquid-solid solution synthesis and the surface was modified using trimethylsilyl chloride (TMCS) as a silylation agent. Silylation surface modification is a method of reacting -OH ligand on the surface of BSTO nanoparticles with Cl in TMCS to generate HCl and replacing the ligand on the surface of nanoparticles with -Si, -CH3. Silylation was optimized by varying the concentration of TMCS, and the structure of the silicon network was confirmed by Fourier-transform infrared spectroscopy. In addition, the crystallinity of BSTO nanoparticles was confirmed by X-ray diffractometer and the size of the nanoparticles was calculated using Scherrer equation. The field emission scanning electron microscopic image observed the change of the surface-modified BSTO particle size, and the contact angle measurement confirmed the hydrophobic property of the contact angle of 120.9° in the optimized nanoparticles. Finally, the surface-modified BSTO dispersion experiment in de-ionized water confirmed the hydrophobic degree of the nanoparticles.

The Synthetic Study of Environmental Contamination at the Seokdae Municipal Waste Landfill in Pusan (부산 석대 생활폐기물 매립장의 환경오염에 대한 종합적 연구)

  • 김병우;정상용;이민희;이병헌
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.98-103
    • /
    • 2001
  • In order to understand the characteristics of leachate at the Seokdae municipal waste landfill in the Pusan city, the correlation between leachate pollution loading and volume of gas production. concentration of gas and subsidence of ground, the characteristical methos, geochemical analyses and laboratory column tests using samples of gases, leachate and surface soil of Seokdae waste landfill area. Through the analysis of water balance, leachate flow rate and pollution loading were estimated. Geistatistical analysis of four gas components ( $O_2$, C $H_4$, $H_2$S and CO) shows the possibility of ground subsidence around the group of a site with high concentration of gas. From geochemical analyses of leachate, EC and Total-Alkalinity of ground subsidence around the group of a site with high concentration of gas. From geochemical analysis of leachate, Ec and Total-Alkalinity were increased, and Cl, Cr, Mn, Cu, Zn, Cd and Pb were decreassed comparing to the part, and the type of water quality was Na-HC $O_3$ in trilinear diagram. It shows that biodecomposition of municipal wastes continues actively. From the analysis of water balance, the total leachate flow rate is about 465.11㎥/day and pure pollution loading of Cl, Mn and Fe are estimated to 223.8kg/day, 0.2kg/day, 0.3kg/day, respectively. The laboratory column test of residual soil and landfill soil shows 0.206cm and 0.019cm for linear velocity(equation omitted), 0.234 $\textrm{cm}^2$/min and 0.018$\textrm{cm}^2$/min for diffusion coefficient ( $D_{ι}$), and 1.136cm and 0.095cm longitudinal dispersion index ($\alpha$$_{ι}$), respective]y. It demonstrates that the delay time of contamination for residual soil is shorter than that of landfill soil.

  • PDF

On-line Monitoring of the Flocs in Mixing Zone using iPDA in the Drinking Water Treatment Plant (정수장 응집혼화공정에서의 응집플럭 연속 모니터링)

  • Ga, Gil-Hyun;Jang, Hyun-Sung;Kim, Young-Beom;Kwak, Jong-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.4
    • /
    • pp.263-271
    • /
    • 2009
  • This study evaluated the flocs forming characteristics in the mixing zone to increase the coagulation effect in the drinking water plant. As a measuring tool of formed flocs, on-line particle dispersion analyzer (iPDA) was used in Y drinking water plant. To evaluate the forming flocs, many parameters such as poly amine, coagulant dosing amount, raw water turbidity, and pH was applied in this study. During the periods of field test, poly aluminium chloride (PACl) as a coagulant was used. With the increase of the raw water turbidities, poly amine was also added as one of aids for increasing in coagulation efficiency. The turbidity and pH of raw water was ranged from 7 to 9 and from 25 to 140 NTU, respectively. The increasing of raw water turbidity brought the bigger floc sizes accordingly. From a regression analysis, $R^2$ value was 0.8040 as a function of T, raw water turbidity. Floc size index (FSI) was obtained from a correlation equation as follows; FSI = 0.9388logT - 0.3214 Also, polyamine gave the bigger flocs the moment it is added to the coagulated water in the rapid mixing zone. One of parameters influencing the floc sizes was the addition of powdered active carbon(PAC) in the mixing zone. In case of higher turbidity of raw water, $R^2$ value was 0.9050 in the parameters of [PACl] and [PAC]; FSI = $0.0407[T]^{0.324}[PACI]^{0.769}[PAC]^{0.178}$ On-line floc monitor was beneficial to evaluate the flocs sizes depending on the many parameters consisting raw water properties, bring the profitable basic data to control the mixing zone more effectively.

Predicting Migration of a Heavy Metal in a Sandy Soil Using Time Domain Reflectometry (TDR을 이용한 사질토양에서의 중금속 이동 추정)

  • Dong-Ju Kim;Doo-Sung Baek;Min-Soo Park
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.1
    • /
    • pp.109-118
    • /
    • 1999
  • Recently, transport parameters of conservative solutes such as KCl in a porous medium have been successfully determined using time domain reflectometry (TDR) . This study was initiated to Investigate the applicability of TDR technique to monitoring the fate of a heavy metal ion in a sandy soil and the distribution of its concentration along travel distance with time. A column test was conducted in a laboratory that consists of monitoring both resident and flux concentrations of $ZnCl_2$in a sandy soil under a breakthrough condition. A tracer of $ZnCl_2$(10 g/L) was injected onto the top surface of the sample as pulse type as soon as a steady-state condition was achieved. Time-series measurements of resistance and electrical conductivity were performed at 10 cm and 20 cm of distances from the inlet boundary by horizontal-positioning of parallel TDR metallic rods and using an EC-meter for the effluent exiting the bottom boundary respectively. In addition. Zn ions of the effluent were analyzed by ICP-AES. Since the mode and position of concentration detected by TDR and effluent were different, comparison between ICP analysis and TDR-detected concentration was made by predicting flux concentration using CDE model accommodating a decay constant with the transport parameters obtained from the resident concentrations. The experimental results showed that the resident concentration resulted in earlier and higher peak than the flux concentration obtained by EC-meter, implying the homogeneity of the packed sandy soil. A close agreement was found between the predicted from the transport parameters obtained by TDR and the measured $ZnCl_2$concentration. This indicates that TDR technique can also be applied to monitoring heavy metal concentrations in the soil once that a decay constant is obtained for a given soil.

  • PDF

Flow and Mixing Behavior at the Tidal Reach of Han River (한강 감조구간에서의 흐름 및 혼합거동)

  • Seo, Il Won;Song, Chang Geun;Lee, Myung Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6B
    • /
    • pp.731-741
    • /
    • 2008
  • Previous studies on the numerical simulation at the tidal reach of Han River tend to restrict downstream boundary as Jeon-ryu station due to difficulties in gaining cross section data and tidal elevation values at Yu-do. But, in this study, geometries beyond the confluence of Gok-reung stream and Im-jin River are constructed based on the numerical sea map; tidal elevation at the downstream boundary, Yu-do is estimated by harmonic analysis of In-cheon tide gage station so that hydrodynamic and diffusion behavior have been analyzed. The domain ranging from Shin-gok submerged weir to Yu-do is selected (which is 36.8 km in length). RMA-2 and RAM4 developed by Il Won Seo (2008) are applied to simulate flow and diffusion behavior, respectively. Numerical results of flow characteristic are compared with the measured data at Jeon-ryu station. Simulation is carried out from June 23 to 25 in 2006 on the ground that hydrologic data is satisfactory and tidal difference is huge during that period. The result shows that reverse flow occurs 5 times according to the tidal elevation at Yu-do and the maximum reverse flow is observed up to Jang-hang IC, which is 32.9 km in length. Also analysis is focused on the process of generation and disappearance of reverse flow, the distribution of water surface elevation and velocity along the maximum velocity line, and the transport of nonconservative pollutant. Pollutant injected from Gul-po stream spreads widely across the river; however, the size of BOD cloud entering from Gok-reung stream is relatively small because water depth at the mid and left side becomes deeper and maximum velocity occurs along the right bank so that transverse mixing is completed quickly. Finally, mixing characteristic of horizontal salinity distribution is obtained by estimating the salinity input with analytical solution of 1D advection-dispersion equation.