• 제목/요약/키워드: Dispensing process

검색결과 67건 처리시간 0.035초

백색 LED 보정 공정 적용을 위한 고점도 형광체 미세 정량토출 공정 (Fine Dispensing Process of High Viscosity Phosphor for Repairing Application of White LED)

  • 양봉수;양영진;김형찬;고정범;조경호;도양회
    • 한국생산제조학회지
    • /
    • 제25권2호
    • /
    • pp.124-131
    • /
    • 2016
  • Several research works for finding and optimizing the methods of dispensing high viscosity phosphor used in the fabrication of white LED's are currently in progress. High viscosity phosphor dispensing with a high accuracy is crucial because the dispensing rate and uniformity directly affect parameters such as the CIE chromaticity diagram, color temperature and luminous flux of white LED's. This study presents a novel method of dispensing high viscosity phosphor using electrohydrodynamic printing. The dispensing rate was optimized less than 0.01 mg phosphor using experiments and optimizing the process parameters including the standoff distance from the nozzle to the substrate, ink supply pressure, and multi-step pulsed waveform magnitude ratio. The dispensing rate was measured by dispensing 20 dots using drop-on-demand with the optimized parameters, and the experiments were repeated 10 times to maximize the data accuracy. The average dispensing rate that can be reliably used for high viscosity phosphor dispensing was 0.0052 mg.

Advances in jet dispensing for flat panel applications

  • Ratledge, Thomas;Suriawidjaja, Floriana
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1455-1461
    • /
    • 2006
  • As OLED manufacturing matures, it requires larger substrate processing. The larger substrates require higher dispensing throughput for UV sealants. Jetting the gaskets of seal materials has provided an increase in performance and dispensing capability. This paper describes the jetting process and deposition capability for applying the UV sealants.

  • PDF

UV 나노임프린트 리소그래피 공정에서 레지스트 도포의 최적화를 통한 잔류층 두께의 최소화 (The Minimization of Residual Layer Thickness by using optimized dispensing method in UVnanoimprint Lithography Process)

  • 김기돈;정준호;심영석;이응숙;김지현;조영근;홍성철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.633-636
    • /
    • 2005
  • Imprint lithography is a promising method for high-resolution and high-throughput lithography using low-cost equipment. As with other nanoimprint methods, ultraviolet-nanoimprint lithography (UV-NIL) resolution appears to be limited only by template resolution, and offers a significant cost of ownership reduction when compared to other next generation lithography (NGL) methods such as EUVL and 157 nm lithography. The purpose of this paper is to suggest optimum values of control parameters of Imprio 100 manufactured by Molecular Imprint, Inc., which is the first commercially available UV-NIL tool, for sound nanoimprint. UV-NIL experiments were performed on Imprio 100 to find dispensing recipe for avoiding air entrapment. Dispensing recipe related to residual layer thickness and uniformity was optimized and 40 nm thick residual layer was achieved.

  • PDF

문헌고찰을 통해 본 의약분업정책 10년의 성과 평가 (Performance evaluation for Ten-years of Government Separation Policy on Prescription and Dispensing of Drugs: A Literature Review Study)

  • 이창우;신의철;박소정;김호종;김원식
    • 보건행정학회지
    • /
    • 제23권2호
    • /
    • pp.188-195
    • /
    • 2013
  • Background: The separation of pharmaceutical prescription and dispensing law was implemented in July 1st of 2000. This law was initiated by government without a through consensus among related stakeholders in the process of policy decision, eventually raising contention about decision making process rather than the performance of the policy. Methods: Therefore, this study tries to identify the accomplishment of the policy goals; based on the last decade's research we assessed inhibition of unnecessary prescription, drug misuse and overuse prevention, prevention of drug-related sentinel events, reducing unnecessary drug utilization, and reducing nation's medical cost. Results: Assessment results represent that government-suggested goal of the policy lacks sufficient evidence to evaluate accomplishment. Conclusion: Unlike other studies that evaluate problems regarding drug dispensing policy in the policy decision process, this study is meaningful in that it evaluated the policy goal based on the last ten years of related study results.

UV nano imprint 공정에서 air bubble area 최소화에 대한 연구 (Experimental study to minimize the air bubble during the imprinting process in UV nanoimprint lithography)

  • 최성웅;이동언;이우일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1934-1938
    • /
    • 2008
  • Formation of air bubble is the one of common defects in UV nano imprint lithography. Location of dispensing and volume of droplets are among the most important parameters in the process. ]n this study, UV curable resin droplets with different volumes were dispensed at different locations and pressed to investigate air bubble formation. By varying volume of droplet and dispensing location, process conditions were found for minimum air bubble area.

  • PDF

조제과오 예방교육이 병원약국의 조제과오 발생율에 미치는 영향 (The Effect of Dispensing Error Prevention Program on the Incidence of Dispensing Error in Hospital Pharmacy)

  • 곽필임;유동주;스리니바산샨무감;용철순;최한곤;이종달;유봉규
    • 한국임상약학회지
    • /
    • 제18권1호
    • /
    • pp.1-5
    • /
    • 2008
  • The goal of this research was to find out the effect of dispensing error prevention program on the incidence of the error in a university hospital pharmacy in Daegu. Dispensing error in this research was defined as the error identified during double-checking process, so it does not mean that the wrong dispensing was administered to patient. Drug name error was the most frequently found error, accounting for about one third of all dispensing errors, and was followed by counting error, strength error, dosage form error, and others. Similar drug name was identified as the most frequent reason for the error, taking up about two thirds of all drug name errors. In this research, six months of dispensing error prevention program resulted in statistically significant reduction of dispensing error by 42 percent. Therefore, it is recommended that hospital pharmacy implement such prevention program regularly to reduce the incidence of the error. Finally, it appears that drug approval authority should closely check the similar drug names and have power to command pharmaceutical company to change the name if pertinent.

  • PDF

건강보험심사청구 자료에 근거한 병용금기 약물의 후향적 약물사용평가 : 처방전 조제 형태별 분석 (Retrospective Drug Utilization Review of Drug-Drug Interaction Criteria Based on Real World Data: Analysis in Terms of Dispensing Types)

  • 이영숙;신현택
    • 한국임상약학회지
    • /
    • 제21권3호
    • /
    • pp.249-255
    • /
    • 2011
  • Objective: To examine the drug use (prescribing) pattern of serious drug-drug interactions (DDIs, contraindicated drug interactions) using real world data. Prescription patterns were examined in terms of dispensing types. Method: Retrospective drug utilization review (DUR) study was performed. One hundred and six datasets of serious DDIs (DDI pairs) were determined among DDI datasets that Ministry of Health & Welfare announced for the DUR system from 2004 to 2005. Electronically transacted ambulatory patients' prescription database to Health Insurance Assessment and Review Services (HIRA) from July, 2005 to June, 2006 was collected with personal information deidentified and analyzed in terms of types of dispensing as a contributing factor. Results: After prescription data analysis per each patient, total number of DDI cases using 95 DDI pairs was 5,511, which accounted for 2.6 cases per patients. DDI cases between two drugs from each of community pharmacy dispensing- type prescription were considerable (63% vs. 24% in those from each of in-institutional dispensing-type prescription and vs. 13% in those from a community pharmacy dispensing-type prescription and an in-institutional dispensingtype prescription). Conclusions: DDI cases from different prescribers were found to be significant. Thus, the concurrent DUR process between prescriptions from different physicians and institutions should be implemented for the safe drug use.

응급의료센터 자동약품분배 캐비닛시스템 운영으로 인한 야간 약국업무개선 (Improvement of Night Pharmacy Service by Automated Dispensing Cabinet System Implementation in Emergency Medical Center)

  • 김경희;김선아;이정연
    • 한국임상약학회지
    • /
    • 제28권1호
    • /
    • pp.51-56
    • /
    • 2018
  • Objective: An automated process for medication preparation and dispensing is essential to improve the quality of work. To reduce night pharmacy workload, a new automated dispensing cabinet system was implemented in a hospital emergency medical center. The purpose of this study is to verify that implementation of an automated dispensing cabinet system will influence the efficiency of night pharmacy work. Methods: To evaluate the new system implementation, a retrospective study and survey was performed in the Ewha Womans University medical center. We compared the dispensing and near-miss error rates between the automated dispensing cabinet system and a night pharmacy. The degree of satisfaction of night shift workers with the new system was surveyed. Results: This study showed significantly reduced dispensing rates of night medications (56.1% and 37.3%; p < 0.01) and near-miss night medications (0.27% and 0.17%; p<0.01). Thirty-two persons responded to the survey, and the satisfaction score for the new system was 4.0 (${\pm}0.8$). The scores were high in order of efficiency, management, and convenience. Time requirement was also reduced because of the simple step of only reviewing in the pharmacy with the new system. Conclusion: Due to system implementation, workload was reduced and time was saved for not only night shift workers but also patients receiving emergency discharge medicine. It was suggested that this will have a positive effect on pharmacist medical service and patient safety.

다중 디스펜싱 방법에 의한 UV-나노임프린트 리소그래피 (UV nanoimprint lithography using a multi-dispensing method)

  • 심영석;손현기;신영재;이응숙;정준호
    • 제어로봇시스템학회논문지
    • /
    • 제10권7호
    • /
    • pp.604-610
    • /
    • 2004
  • Ultraviolet-nanoimprint lithography (UV-NIL) is a promising method for cost-effectively defining nanoscale structures at room temperature and low pressure. Since the resolution of transferred nanostructures depends strongly upon that of nanostamps, the nanostamp fabrication technology is a key technology to UV-NIL. In this paper, a $5\times5\times0.09$ in. quartz stamp whose critical dimension is 377 nm was fabricated using the etching process in which a Cr film was employed as a hard mask for transferring nanostructures onto the quartz plate. To effectively apply the fabricated 5-in. stamp to UV-NIL on a 4-in. Si wafer, we have proposed a new UV-NIL process using a multi-dispensing method as a way to supply resist on a wafer. Experiments have shown that the multi-dispensing method can enable UV-NIL using a large-area stamp.