• Title/Summary/Keyword: Disinfection facilities

Search Result 66, Processing Time 0.033 seconds

An Analysis Microbiological Contamination on the Facilities and Utilities of Japanese Restaurants (일식 레스토랑 설비와 조리기구의 미생물 오염 실태 분석)

  • Kim, Gi-Young;Park, Gye-Young;Chae, Myoung-Hee
    • Culinary science and hospitality research
    • /
    • v.15 no.4
    • /
    • pp.9-17
    • /
    • 2009
  • The microbiological examinations was conducted for the hygienic evaluation on ten Japanese restaurants during summer season in Gwangju, Korea. Total two hundreds swabbed samples using sponge were collected from the surface of facilities and utensils at restaurants. The number of total microorganism, coliform, E. coli, Staphylococcus, Salmonella, and Listeria were measured. The results demonstrated that most swabbed samples were contaminated with microorganisms and coliforms. The degree of contamination depended on the sample sites. The severely contaminated sites were floor, trench, and working table for the fish and total counts of those samples were over $10^4$ CFU/100 $cm^2$. The coliforms were detected on the floor, trench, and wood cutting board over $10^3$ CFU/100 $cm^2$. Moreover, coliforms was detected on the towel, dish, and working place for fish and vegetables. The E. coli was detected on the floor and trench of several restaurants. The Staphylococcus spp. was detected on the cutting board, towel, floor and trench of several restaurants. The Salmonella spp. and Listeria spp. were not detected all over the samples. From those results showed that sanitation management and disinfection were required on the Japanese restaurants.

  • PDF

Evauation of Hygienic Status of High School Foodservice using ATP Bioluminescence Assay & Microorganism Test Strips (ATP Bioluminescence와 간이미생물배지를 이용한 고등학교 급식시설의 위생상태 조사연구)

  • Jang, Jae-Seon;Hwang, Seong-Hee
    • The Korean Journal of Food And Nutrition
    • /
    • v.28 no.5
    • /
    • pp.918-925
    • /
    • 2015
  • An investigation was conducted to evaluate the hygienic status of 33 high school foodservice systems in Yongin city by using hygiene management guide checklist, ATP bioluminescence assay and microbe inspection petrifilm (APC, coliform group, Staphylococcus aureus) of food utensils during use. The 22 hygiene management guide checklist items about facilities, personal hygiene, food control, distribution, washing and disinfection had good grade but there were some inadequate behaviors on observation. The inspection results showed their sanitary condition met the level B of the recommendation of Korea method, it means sanitary management system get settled but more practical CCP system was needed. ATP bioluminescence assay was conducted on surface of food facilities, ATP ranged 425~2,552 RLU on gloves, 541~70,251 RLU on apron, 1,596~88,490 RLU on working desk, 1,177~263,813 RLU on sterilizer grip, 715~32,814 RLU on sterilizer shelf, 114~619,725 RLU on refrigerator grip, 677~319,007 RLU on refrigerator shelf, 71~196,725 RLU on freezer grip, 1,535~233,375 RLU on freezer shelf. APC ranged $66.7{\pm}29.0CFU$ on freezer grip, $102.1{\pm}35.9CFU$ on refrigerator grip, $45.4{\pm}28.2CFU$ on heating cabinet grip, $58.8{\pm}40.4CFU$ on sterilizer grip, the number of coliform group ranged $5.6{\pm}4.9CFU$ on freezer grip, $9.1{\pm}8.7CFU$ on refrigerator grip, $1.2{\pm}1.1CFU$ on heating cabinet grip, $4.5{\pm}4.4CFU$ on sterilizer grip. S. aureus ranged $8.0{\pm}5.6CFU$ on freezer grip, $12.2{\pm}9.6CFU$ on refrigerator grip, $2.1{\pm}1.6CFU$ on heating cabinet grip, $11.6{\pm}6.4CFU$ on sterilizer grip.

Study on the characterization of dissolved organic matters in Nakdong River (낙동강의 용존 유기물질 특성에 관한 연구)

  • Heo, Seong-Nam;Park, Jeong-Min;Im, Tae-Hyo;Shin, Chan-Ki
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.13-26
    • /
    • 2007
  • Changes in the characteristics of dissolved organic matter was studied at selected stations in the Nakdong river basin using physical and chemical methods. Characteristics of dissolved organic matters were analysed and assessed. Production of disinfection byproducts were also investigated. 1. Result of relatedness study among each items of analyses showed that relatedness on BOD values were highest with cattle excrement treatment facilities where there is no synthetic organic materials and relatedness on $COD_{Mn}$ were highest at the mainstream Nakdong river. In case of $COD_{Cr}$ (which has more oxidative power than $COD_{Mn}$), the values were higher in the sidestreams indicating the higher content of recalcitrant compounds. The relatedness values for the $UV_{254}$ also showed higher values in the sidestreams and treatment facilities than mainstream indicating the presence of organic aromatic compounds. 2. Ratio of DOC on total organic carbon were higher in the mainstream which is attributable to the influent particulate organic materials produced by agricultural activities. The values were 10-15% higher in the mainstream compared with sidestreams. 3. Result of biodegradability test indicate that concentrations of recalcitrant DOC were higher in the sidestreams than in the mainstream. The values of recalcitrant DOC were higher with the forest stream indicating the effect of soil oriented humic substances. 4. Result of THM production test carried out at 10 stations in the Nakdong river show that $CHCl_3$ was detected with the highest value and the value was highest at Waekwan station.

Research on Bacterial Distribution of Public Lavatory (공중이용 화장실의 미생물 분포 조사)

  • Choi, Han-Young;Kwon, Woo-Taeg;Lee, Woo-Sik;Lee, Hyang
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.520-528
    • /
    • 2012
  • Objective: This study was performed to assess bacterial distribution concerned in sanitation management of public lavatory in Seoul. Methods: In this research, bacteriological investigation on public lavatory was accomplished for bidet water, bidet nozzle, washbowl and lavatory stool in the 50 public facilities such as public institutions, subway stations, cinema, department stores, large-scale buildings and hospitals amount to 374 specimens. Results: The geometric mean of colony forming unit(CFU) in total aerobic colony count were analyzed as follows; $5.2{\times}10^2/100cm^2$ on lavatory stool, $7.2{\times}10^3/ea$ on bidet nozzle, $7.8{\times}10^3/ea$ on center ring of washbowl, $1.4{\times}10/mL$ in bidet water (ml) and 7.0/ea on doorknob. Opportunistically pathogenic germs such as Staphylococcus aureus, Escherichia coli, Enterobacter cloacae, Pseudomonas aeruginosa were isolated in 3.7%, 5.9%, 3.2% and 1.9% of total specimens, respectively. Conclusion: The result of this study shows that there were some facilities where the pathogenic germs were detected to may cause urological infection. And the CFU of general bacteria as the representative indicator of disinfection and lavatory cleaning were high enough to imply the improvement of sanitation management of public lavatories should be contrived.

Infection management for emergency rescue equipment (119 구급대의 구급장비 감염 관리와 실태조사)

  • Park, So-Mi;Lee, Hyo-Ju;Choi, Jang-Hui;Kim, Jong-Ho
    • The Korean Journal of Emergency Medical Services
    • /
    • v.21 no.1
    • /
    • pp.87-98
    • /
    • 2017
  • Purpose: This study investigated the use of infection management and the frequency of emergency equipment sterilization by emergency rescue crews to provide basic guidelines and suggestions for infection control. Methods: A self-reported questionnaire was completed by 160 emergency medical technician rescue crews in J area from May 7 to May 22 in 2015. The questionnaire consisted of 95 items, including the general characteristics of the subjects (8 items), the use of emergency equipment (33 items), the frequency of facility sterilization (33 items), infection control (12 items), vaccination (4 items), and the use of personal protective equipment (5 items). Results: In all, 97.3% of respondents were aware of the "Guidelines of Infection management for Rescue Operators' and 90.9% received training on infection control. A total of 72.7% and 47.3% of rescue centers were equipped with disinfection facilities and laundry rooms, respectively. The average frequency of sterilization was $3.17{\pm}0.75$, which significantly differed for teams with more clinical experience (p=.050) and teams with three members (p=.030). The average score for individual protective equipment supplies was $1.95{\pm}0.66$. Conclusion: For proper infection management of emergency equipment, our results suggest that the number of crew members should be increased for each ambulance, protective equipment and rescue products should be supplied, and the number of facilities for sterilization and laundry at rescue centers should be doubled.

A study on pollutants removal characteristics of domestic riverbed filtration and riverbank filtration intake facilities (국내 복류수 및 강변여과수 취수시설의 오염물질 제거특성에 관한 연구)

  • Chan-woo Jeong;Sun-ick Lee;Sung-woo Shin;Chang-hyun Song;Bu-geun Jo;Jae-won Choi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.5
    • /
    • pp.281-288
    • /
    • 2023
  • This study was performed to evaluate the pollutants removal characteristics of two types of RBFs(Riverbank filtration, Riverbed filtration) intake facilities installed in Nakdong River and in Hwang River respectively. The capacity of each RBF is 45,000 m3/d for riverbank filtration intake facility and 3,500 m3/d for riverbed filtration intake facility. According to data collected in the riverbank filtration site, removal rate of each pollutant was about BOD(Biochemical Oxygen Demand) 52%, TOC(Total Organic Carbon) 57%, SS(Suspended Solids) 44%, Total coliforms 99% correspondingly. Furthermore, Microcystins(-LR,-YR,-RR) were not found in riverbank filtered water compared to surface water in Nakdong River. DOC(Dissolved Organic Carbon) and Humics which are precursors of disinfection byproduct were also reported to be removed about 59% for DOC, 65% for Humics. Based on data analysis in riverbed filtration site in Hwang River, removal rate of each contaminant reaches to BOD 33.3%, TOC 38.5%, SS 38.9%, DOC 22.2%, UV254 21.2%, Total coliforms 73.8% respectively. Additionally, microplastics were also inspected that there was no obvious removal rate in riverbed filtered water compared to surface water in Hwang River.

Removal of taste and odor causing compounds in drinking water using Pulse UV System (Pulse UV 장치를 이용한 먹는 물의 이취미 유발물질 제거효과에 관한 연구)

  • Sohn, Jin-Sik;Park, Soon-Ho;Jung, Eui-Taek
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.219-228
    • /
    • 2012
  • Problems due to the taste and odor in drinking water are common in treatment facilities around the world. Taste and odor are perceived by the public as the primary indicators of the safely and acceptability of drinking water, and are mainly caused by the presence of two semi-volatile compounds-2-methylisoborneol(2-MIB) and geosmin. Conventional treatment processes in water treatment plants, such as coagulation, sedimentation and chlorination have been found to be ineffective for the removal of 2-MIB and geosmin. Pulse UV system is a new UV irradiation system that is a non-mercury lamp-based alternative to currently used continuous wave systems for water disinfection. This study shows pulse UV system to be effective in treatment of these two compounds. Geosmin removal efficiency of UV process alone achieved approximately 70% at 10sec contact time. 2-MIB removal efficiency of UV only process achieved approximately 60% at 10sec contact time. The addition of $H_{2}O_{2}$ 7mg/L increased geosmin and 2-MIB removal efficiency upto approximately 94% and 91%, respectively.

Development of Clean Water Supplying System for Greenhouse Cultivation and Convenience Water (II) - Assessment of the FDA System through a Site Application - (시설용수 및 영농편의용수 공급시스템 개발 (II) - FDA 시스템 현장적용성 평가 -)

  • Lee, Kwang-Ya;Choi, Kyung-Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.101-106
    • /
    • 2009
  • The previous study developed the Filter-Disinfection-Adsorption (FDA) system to provide clean irrigation water for greenhouse cultivation as well as convenience water to farmers. In this study, the field examination was undertaken to assess performance of the FDA system. The field application was made in the suburb of Daegu, one of the large city in Korea. The study area located near by down-stream of Gum-Ho river is suffering low irrigation water quality problems with no water supply service facilities. Four water quality parameters including Suspended Solid (SS), Biological Oxygen Demand (BOD), coliform, and turbidity were selected to test the purification performance of FDA system. Also in order to improve the system, this study investigated the defects of using the FDA system through field monitoring. As results, it was found that this system can be used to supply good quality of irrigation water for greenhouse cultivation and also provide convenience water to farmers in the field areas of no water supply services.

The Evaluation of Performance Limiting Factors for the Optimization of Drinking Water Treatment (정수장 최적화를 위한 성능제한인자 평가에 관한 연구)

  • Kim, Jeong Hyun;Bae, Chul Ho;Park, No Suk;Moon, Yong Taik;Lee, Sun Ju;Kown, Soon Buhm;Ahn, Hyo Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.78-91
    • /
    • 2005
  • Performance limiting factors (PLFs) derived from 161 drinking water treatment plants (DWTPs), assessed by International Technical Diagnosis & Assistance Center, were analyzed and evaluated in more detail in this study. In order to conduct study, 161 DWTPs were divided into five categories depending on their capacity, and into twelve groups according to processes and facilities. From the results of analysis, PLFs and their distribution ratio derived from each category were significantly different. Filtration was the most important performance limiting process in all DWTPs of five categories, and the PLFs in filtration were backwashing velocity, media configuration, bed depth, and formation of mud-ball. The PLFs in coagulation-flocculation process were found out to be coagulant dosage, mixing speed, mechanical problems, and others in the order of frequency of occurrence. Also, insufficient disinfection ability that is resulted from insufficient hydraulic detention time and improper chlorine dose and injection point, is the most significant among PLFs in a clear well. In the case of sedimentation, inappropriate baffle structure and excessive upward velocity were PLFs. In addition, the results showed that high turbid water and low alkalinity in a rainy season, ferric and manganese ions, and ammonia nitrogen have been contributed significantly on the performance of DWTPs.

Perception of the HACCP system operators on livestock product manufacturers

  • Kim, Jung-Hyun;Nam, Ki-Chang;Jo, Cheorun;Lim, Dong-Gyun
    • Journal of Animal Science and Technology
    • /
    • v.56 no.5
    • /
    • pp.19.1-19.6
    • /
    • 2014
  • The purpose of this study was to investigate crucial factors on HACCP system implementation in domestic livestock product plants, and to offer job satisfaction and the career prospect of HACCP system operators. The survey was carried out by selecting 150 HACCP system operators who implemented HACCP system. The respondents claimed that the most important contents in HACCP system operation were to assemble HACCP team (21.8%), and the second was to monitoring (20.0%). Documentation and recording (16.9%) and verification (11.1%) were followed. The respondents answered the major factor in sanitation management was cleaning/washing/disinfection (18.9%) and inspection (18.4%). The results showed that there were significant differences in the prospect of occupation in HACCP system operator by the gender (p < 0.015), age, livestock product facilities, service period, and position (p < 0.001). The respondents from HACCP system operator were satisfied with their job (73%) and also showed optimistic prospect of occupation (82%).