The Evaluation of Performance Limiting Factors for the Optimization of Drinking Water Treatment  

Kim, Jeong Hyun (한국수자원공사 수자원연구원)
Bae, Chul Ho (한국수자원공사 수자원연구원)
Park, No Suk (한국수자원공사 수자원연구원)
Moon, Yong Taik (한국수자원공사 수자원연구원)
Lee, Sun Ju (한국수자원공사 수자원연구원)
Kown, Soon Buhm (한국수자원공사 수자원연구원)
Ahn, Hyo Won (한국수자원공사 수자원연구원)
Publication Information
Journal of Korean Society of Water and Wastewater / v.19, no.1, 2005 , pp. 78-91 More about this Journal
Abstract
Performance limiting factors (PLFs) derived from 161 drinking water treatment plants (DWTPs), assessed by International Technical Diagnosis & Assistance Center, were analyzed and evaluated in more detail in this study. In order to conduct study, 161 DWTPs were divided into five categories depending on their capacity, and into twelve groups according to processes and facilities. From the results of analysis, PLFs and their distribution ratio derived from each category were significantly different. Filtration was the most important performance limiting process in all DWTPs of five categories, and the PLFs in filtration were backwashing velocity, media configuration, bed depth, and formation of mud-ball. The PLFs in coagulation-flocculation process were found out to be coagulant dosage, mixing speed, mechanical problems, and others in the order of frequency of occurrence. Also, insufficient disinfection ability that is resulted from insufficient hydraulic detention time and improper chlorine dose and injection point, is the most significant among PLFs in a clear well. In the case of sedimentation, inappropriate baffle structure and excessive upward velocity were PLFs. In addition, the results showed that high turbid water and low alkalinity in a rainy season, ferric and manganese ions, and ammonia nitrogen have been contributed significantly on the performance of DWTPs.
Keywords
Performance limiting factors; assessment; capacity; process type;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Larry D. DeMers, Alison Gusses Dugan, R. Scott Summers and James Uber (2003), Optimization beyond turbidity-Fine Tuning the Disinfection Process and Control of Byproduct Formation, AWWA annual conference proceeding
2 하은정, 오정우, 김정현, 윤장근 (2000) 소규모정수장 기능 진단에 의한 성능제한 인자의 도출 및 검증 연구, 상하수도학회지, 14(3), pp.240-250
3 환경관리공단 (2003) 수돗물 수질개선과 중소규모 상수도 시설의 효율적 관리방안 연구, 환경관리공단
4 AWWA, (2004b) Partnership for Safe Water Annual Data Summary Report, AWWA
5 Bob A. Hegg and Larry D. DeMers (2003) Performance Based Training: A Proved Approach to Improve Water Treatment Plant Performance, AWWA annual conference proceeding
6 AWWA, (2004a) Self-Assessment for Treatment Plant Optimization, AWWA
7 한국수자원공사, 국제수도진단센터 기술지원 및 진단보고서, 2000-2003 년
8 정호진, 박승철, 구봉헌 (2001) CCP 기법을 이용한 정수장 기술진단 사례, 환경과학논집, 6(1). pp.293-305   PUBMED
9 EPA (1998) CCP Handbook, EPA
10 AWWA, (2004c) Hindsight is 20/20, Using History to Avoid Waterborne Disease Outbreaks, 96(6), 2004
11 박훈수, 염철민, 윤제용 (2001) 국내 정수처리공정에서 오존공정 시설의 현황과 특성, 상하수도학회지, 15(4), pp.279-293
12 현인환 (1998) 정수장 진단의 개념과 체계적 진단 기법, 대한상하수도학회, 수도연구회 심포지움. pp. 10-31