• Title/Summary/Keyword: Discrete Range

Search Result 289, Processing Time 0.027 seconds

Complexity Estimation Based Work Load Balancing for a Parallel Lidar Waveform Decomposition Algorithm

  • Jung, Jin-Ha;Crawford, Melba M.;Lee, Sang-Hoon
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.6
    • /
    • pp.547-557
    • /
    • 2009
  • LIDAR (LIght Detection And Ranging) is an active remote sensing technology which provides 3D coordinates of the Earth's surface by performing range measurements from the sensor. Early small footprint LIDAR systems recorded multiple discrete returns from the back-scattered energy. Recent advances in LIDAR hardware now make it possible to record full digital waveforms of the returned energy. LIDAR waveform decomposition involves separating the return waveform into a mixture of components which are then used to characterize the original data. The most common statistical mixture model used for this process is the Gaussian mixture. Waveform decomposition plays an important role in LIDAR waveform processing, since the resulting components are expected to represent reflection surfaces within waveform footprints. Hence the decomposition results ultimately affect the interpretation of LIDAR waveform data. Computational requirements in the waveform decomposition process result from two factors; (1) estimation of the number of components in a mixture and the resulting parameter estimates, which are inter-related and cannot be solved separately, and (2) parameter optimization does not have a closed form solution, and thus needs to be solved iteratively. The current state-of-the-art airborne LIDAR system acquires more than 50,000 waveforms per second, so decomposing the enormous number of waveforms is challenging using traditional single processor architecture. To tackle this issue, four parallel LIDAR waveform decomposition algorithms with different work load balancing schemes - (1) no weighting, (2) a decomposition results-based linear weighting, (3) a decomposition results-based squared weighting, and (4) a decomposition time-based linear weighting - were developed and tested with varying number of processors (8-256). The results were compared in terms of efficiency. Overall, the decomposition time-based linear weighting work load balancing approach yielded the best performance among four approaches.

A Comparative Analysis on Facial Expression in Advertisements -By Utilising Facial Action Coding System(FACS) (광고 속의 얼굴 표정에 따른 비교 연구 -FACS를 활용하여)

  • An, Kyoung Hee
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.3
    • /
    • pp.61-71
    • /
    • 2019
  • Due to the limit of the time length of advertisement, facial expressions among the types of nonverbal communication are much more expressive and convincing to appeal to costumers. The purpose of this paper is not only to investigate how facial expressions are portrayed but also to examine how facial expressions convey emotion in TV advertisements. Research subjects are TV advertisements of and which had the wide range of popularity for customer known as one of the most touching commercials. The research method is Facial Action Coding System based on the theoretical perspective of a discrete emotions and designed to measure specific facial muscle movements. This research is to analyse the implications of facial expressions in the both TV ads by using FACS based on Psychology as well as anatomy. From the all the result of this, it is shown that the facial expressions portrayed with the conflict of emotional states and the dramatic emotional relief of the heroin could move more customers' emotions.

Comparison of Scattered Light of ex vivo Mouse Neutrophils by Different Wavelength Laser Irradiation (2개의 레이저 파장에 따른 마우스 호중구의 산란광 비교 연구)

  • Park, Jae-Sung;Son, Min-Ji;Hwang, Chang-Soon;Lee, Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.365-378
    • /
    • 2022
  • Complete blood cell count(CBC) is a technique that counts leukocytes for each type of blood cell being analyzed. The principle is that laser is incident to ex vivo flowing leukocytes in a microcapillary tube and scattered light occurs by laser and leukocytes. By collecting the scattered light, we can count the types of cells because different cells generate different light-scattering patterns. However, the technique has an intrinsic limitation, scattering pattern is shown in a wide range region in the resulting, which makes it difficult to accurate analyze and use fluorescent dyes. To overcome this limitation, a new design of CBC with a dual laser, which irradiates with orthogonal angles for collecting quad-scattering information was proposed. Before development, the scattering difference depending on wavelength must be investigated to only catch up to the scattered signal by angles. Some studies, which focused on simple particles, have been conducted to theoretically and experimentally investigate different scatterings by wavelength. In this study, we propose an optical system for measuring scattered light and investigate a complex particle. As a result, the green laser made strong scattering signals in both the forward and side direction: 10% and 30%, respectively.

2D numerical study of the mechanical behaviour of non-persistent jointed rock masses under uniaxial and biaxial compression tests

  • Vaziri, Mojtaba Rabiei;Tavakoli, Hossein;Bahaaddini, Mojtaba
    • Geomechanics and Engineering
    • /
    • v.28 no.2
    • /
    • pp.117-133
    • /
    • 2022
  • Determination of the mechanical behaviour of jointed rock masses has been a challenge for rock engineers for decades. This problem is more pronounced for non-persistent jointed rock masses due to complicated interaction of rock bridges on the overall behaviour. This paper aims to study the effect of a non-persistent joint set configuration on the mechanical behaviour of rock materials under both uniaxial and biaxial compression tests using a discrete element code. The numerical simulation of biaxial compressive strength of rock masses has been challenging in the past due to shortcomings of bonded particle models in reproducing the failure envelope of rock materials. This problem was resolved in this study by employing the flat-joint contact model. The validity of the numerical model was investigated through a comprehensive comparative study against physical uniaxial and biaxial compression experiments. Good agreement was found between numerical and experimental tests in terms of the recorded peak strength and the failure mode in both loading conditions. Studies on the effect of joint orientation on the failure mode showed that four zones of intact, transition to block rotation, block rotation and transition to intact failure occurs when the joint dip angle varies from 0° to 90°. It was found that the applied confining stress can significantly alter the range of these zones. It was observed that the minimum strength occurs at the joint dip angle of around 45 degrees under different confining stresses. It was also found that the joint orientation can alter the post peak behaviour and the lowest brittleness was observed at the block rotation zone.

Sequential Delivery of Neodymium:Yttrium-Aluminum-Garnet and Alexandrite Laser Pulses for Treating Light Brown Seborrheic Keratoses

  • Cho, Sung Bin;Oh, Doojin;Yoo, Kwang Ho
    • Medical Lasers
    • /
    • v.8 no.1
    • /
    • pp.24-27
    • /
    • 2019
  • Seborrheic keratoses (SKs) have been treated with non-ablative longpulsed (LP) lasers, including LP 532-nm neodymium (Nd): yttrium aluminum garnet (YAG), LP 695-nm ruby, LP 755-nm alexandrite (Alex), and LP 1,064-nm Nd:YAG lasers, with a pulse durations of 1-300 msec. Dual-wavelength LP 755-nm Alex/1,064-nm Nd:YAG laser systems have been used to remove hair follicles and treat various vascular and pigmented disorders by sequentially delivering two pulses of different wavelengths with interpulse intervals in the millisecond range. This paper reports the case of a female patient with multiple, discrete, light brown SKs on the dorsum of both hands that were treated effectively with one session of dual-wavelength LP 1,064-nm Nd:YAG/755-nm Alex laser treatment. The treatment settings for the LP Nd:YAG laser were comprised of a wavelength of 1,064 nm, fluence of 50 J/cm2, pulse duration of 5 msec, and beam size of 3 mm. The settings for the LP Alex laser were comprised of a wavelength of 755 nm, fluence of 50 J/cm2, pulse duration of 5 msec, and beam size of 3 mm. A hybrid mode was used to automatically deliver LP Nd:YAG and LP Alex laser pulses in succession at interpulse intervals of 20 msec. Six weeks after treatment, the patient exhibited remarkable improvement of the light brown seborrheic keratoses and was satisfied with the results.

Proton Affinity Distributions of Humic Acid Extracted from Upland and Paddy Soils (논·밭토양으로부터 추출한 Humic Acid의 수소이온 친화력 분포)

  • Jeong, Chang-Yoon;Park, Chan-Won;Kim, Jeong-Gyu;Lim, Soo-Kil
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.4
    • /
    • pp.429-439
    • /
    • 1999
  • Potentiometric titration data were collected for some humic acids purified from Korean upland and paddy soils over a range of pH (3.0 - 11.0) with $NaNO_3$ background electrolyte concentrations (0.01, 0.10, 0.50 and 1.00 M). The data were applied to model A and V which included both intrinsic heterogeneity of humic materials and electrostatic interaction influences on binding sites. The elemental analysis were conducted for various type of humic samples. The $E_4/E_6$ ratio proposed negative correlation with the total carboxyl groups ($r^2$= 0.9988). The charge ($cmol_c\;kg^{-1}$) on the humic acids became more negative as the ionic strength increased. In both continuous and batch titrations, the ionic strength effect was greater in Namweon series (pH 6.39) than others at pH 5.00. The effect of ionic strength on surface charge appears to be greater in batch titrations. This could suggest that continuous titrations do not represent an equilibrium state and the effects of electrolyte concentration was not fully realized during the course of titrations. Both models described experimental data obtained from continuous and batch titrations well over a range of ionic strengths. Model A is more simpler than model V but adaptes more fitted parameters. Thus, the observed change in apparent binding constants with surface charge is regarded solely due to electrostatic influences rather than functional group heterogeneity. However, Model V is more mechanistically realistic in a number of discrete ligand binding sites.

  • PDF

Validation of Sea Surface Wind Estimated from KOMPSAT-5 Backscattering Coefficient Data (KOMPSAT-5 후방산란계수 자료로 산출된 해상풍 검증)

  • Jang, Jae-Cheol;Park, Kyung-Ae;Yang, Dochul
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_3
    • /
    • pp.1383-1398
    • /
    • 2018
  • Sea surface wind is one of the most fundamental variables for understanding diverse marine phenomena. Although scatterometers have produced global wind field data since the early 1990's, the data has been used limitedly in oceanic applications due to it slow spatial resolution, especially at coastal regions. Synthetic Aperture Radar (SAR) is capable to produce high resolution wind field data. KOMPSAT-5 is the first Korean satellite equipped with X-band SAR instrument and is able to retrieve the sea surface wind. This study presents the validation results of sea surface wind derived from the KOMPSAT-5 backscattering coefficient data for the first time. We collected 18 KOMPSAT-5 ES mode data to produce a matchup database collocated with buoy stations. In order to calculate the accurate wind speed, we preprocessed the SAR data, including land masking, speckle noise reduction, and ship detection, and converted the in-situ wind to 10-m neutral wind as reference wind data using Liu-Katsaros-Businger (LKB) model. The sea surface winds based on XMOD2 show root-mean-square errors of about $2.41-2.74m\;s^{-1}$ depending on backscattering coefficient conversion equations. In-depth analyses on the wind speed errors derived from KOMPSAT-5 backscattering coefficient data reveal the existence of diverse potential error factors such as image quality related to range ambiguity, discrete and discontinuous distribution of incidence angle, change in marine atmospheric environment, impacts on atmospheric gravity waves, ocean wave spectrum, and internal wave.

Settling Characteristics of Natural Loess Particles in Seawater (해수 중에서 자연상태 황토입자의 침강특성)

  • KIM Sung-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.6
    • /
    • pp.706-712
    • /
    • 1999
  • PSD (particle size distribution) for 2,000 mg/$\ell$ natural loess in seawater showed normal distribution cure at 0 minute settling time, accompanying with very large particle distribution range with its mean particle diameter of 31.6 $\mu$m and coencient of variance of $72.6\%$, With elapsed time it showed that the PSD was rapidly changed from normal distribution cure to abnormal distribution curve, steepened the right-hand side of it and its coefficient of variance was getting increased because of rapid settling of large size particles, Cumulative weight distribution showed that 2,000 mg/$\ell$ natural loess in seawater was almost $100\%$ constituted of particles bigger than 20 $\mu$m in diameter. Ratio of $V_s/(D_{bm})^{1/2}$ for loess particles in seawater was increased with increase of particle size in geometrical progression. Almost all loess particles in seawater had Stokes settling velocity not less than 2,255 times of Brownian diffusion coefficient, There was almost to EDL (about 0.4 nm) around natural loess particles in seawater, Thus, there was always LVDW attractive force between loess particles approaching each other in seawater, and almost no EDL repulsive force. Loess particles were not always in the condition of easy floe formation. Concentration of natural loess in seawater increasing from 400 mg/$\ell$ to 10,000 mg/$\ell$, characteristics of the settling was changed from Type I settling (discrete settling) to Type II settling (flocculation settling). PVD (particle volume distribution) showed that natural loess particles in seawater were largely constituted of two types of particles, such as rapidly settling particles and suspended and dispersed particles for a long time. Amount of the latter was much less than that of the former.

  • PDF

Prediction of the Glucose Concentration Based on Its Optical Absorbance at Multiple Discrete Wavelengths (복수 개의 광파장에 대한 상대적 흡광 특성을 이용한 글루코스 농도 측정)

  • Kim, Ki-Do;Son, Geun-Sik;Lim, Seong-Soo;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.6
    • /
    • pp.416-421
    • /
    • 2008
  • A scheme for predicting the concentration of a glucose solution based on its relative optical absorbance at multiple probe wavelengths was proposed and verified. The relative absorbance at each of the probe wavelength was obtained with respect to the absorbance at a reference wavelength. The single reference wavelength (1310 nm) and a group of four different probe wavelengths (1064, 1550, 1685, 1798 nm) were selected to exhibit the glucose absorbance with opposite signs, thereby enhancing the accuracy of the prediction. The final glucose concentration was estimated by taking the average of the predicted values provided by the four probe wavelengths. The absorbance of the glucose solution for the path length of 5 mm was $-1.42{\times}10^{-6}\;AU$/(mg/dL) at the reference wavelength of 1310 nm and peaked at $+8.12{\times}10^{-6}\;AU$/(mg/dL) at 1685 nm. The concentration of the glucose solution was decently predicted by means of the proposed scheme with the standard error of prediction of ${\sim}28\;mg/dL$. In addition, the influence of the ambient temperature and the fat thickness upon the prediction of the glucose concentration was examined. The absorption change with the temperature was $-9.1{\times}10^{-5}\;AU/^{\circ}C$ in the temperature range of $26{\sim}40^{\circ}C$ at the reference wavelength, and $-2.08{\times}10^{-2}\;AU/^{\circ}C$ at 1550 nm. And the absorption change with respect to the fat thickness was +1.093 AU/mm at the probe wavelength of 1685 nm.

Effects of variety, region and season on near infrared reflectance spectroscopic analysis of quality parameters in red wine grapes

  • Esler, Michael B.;Gishen, Mark;Francis, I.Leigh;Dambergs, Robert G.;Kambouris, Ambrosias;Cynkar, Wies U.;Boehm, David R.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1523-1523
    • /
    • 2001
  • The wine industry requires practical methods for objectively measuring the composition of both red wine grapes on the vine to determine optimal harvest time; and of freshly harvested grapes for efficient allocation to vinery process streams for particular red wine products, and to determine payment of contract grapegrowers. To be practical for industry application these methods must be rapid, inexpensive and accurate. In most cases this restricts the analyses available to measurement of TSS (total soluble solids, predominantly sugars) by refractometry and pH by electropotentiometry. These two parameters, however, do not provide a comprehensive compositional characterization for the purpose of winemaking. The concentration of anthocyanin pigment in red wine grapes is an accepted indicator of potential wine quality and price. However, routine analysis for total anthocyanins is not considered as a practical option by the wider wine industry because of the high cost and slow turnaround time of this multi-step wet chemical laboratory analysis. Recent work by this ${group}^{l,2}$ has established the capability of near infrared (NIR) spectroscopy to provide rapid, accurate and simultaneous measurement of total anthocyanins, TSS and pH in red wine grapes. The analyses may be carried out equally well using either research grade scanning spectrometers or much simpler reduced spectral range portable diode-array based instrumentation. We have recently expanded on this work by collecting thousands of red wine grape samples in Australia. The sample set spans two vintages (1999 and 2000), five distinct geographical winegrowing regions and three main red wine grape varieties used in Australia (Cabernet Sauvignon, Shiraz and Merlot). Homogenized grape samples were scanned in diffuse reflectance mode on a FOSE NIR Systems6500 spectrometer and subject to laboratory analysis by the traditional methods for total anthocyanins, TSS and pH. We report here an analysis of the correlations between the NIR spectra and the laboratory data using standard chemometric algorithms within The Unscrambler software package. In particular, various subsets of the total data set are considered in turn to elucidate the effects of vintage, geographical area and grape variety on the measurement of grape composition by NIR spectroscopy. The relative ability of discrete calibrations to predict within and across these differences is considered. The results are then used to propose an optimal calibration strategy for red wine grape analysis.

  • PDF