• 제목/요약/키워드: Disconnecting Switchgear

검색결과 7건 처리시간 0.018초

170kV GIS용 단로기의 현장 사용 실태 조사 (A Study on the Actual Condition Investigation of the Disconnecting Switchgear of 170kV GIS)

  • 이은석;김종서;천종철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1180-1183
    • /
    • 2003
  • 170kV GIS(Gas Insulated Switchgear) is widely used in large industrial factory-electrical facilities of private use because has many benefits. But Other equipments's failures are occurred by GIS failures and give rise economic problems to user. Therefore we will examine the actual condition of the 170kV GIS-electrical facilities of private use and are able to confirm the distribution characteristic analysis of disconnecting switchgear. In this paper, we presents the actual condition investigation of the disconnecting switchgear of 170kV GIS-electrical facilities of private use by post - failure pattern, inspection method, test equipments and so forth.

  • PDF

송변전계통 전력개폐설비의 고장 실태조사 연구 (Analysis on Fault for Switching Devices in Transmission & Substation System)

  • 이봉희;이희성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.415-417
    • /
    • 1999
  • Recently, Reliability of switching devices for transmission & substation system is very important. Therefore, We have investigated fault trend of switching devices from 1982 to 1998 This paper presents fault analysis on Circuit Breakers, Disconnecting Switch, Gas Insulated Switchgear, etc. Thus, this paper will help improve design, manufacture, construction technology and maintenance method.

  • PDF

가스절연개폐장치용 감시시스템 적용에 관한 연구 (A study on the Application of a Monitoring System for Gas Insulaterd Switchgear)

  • 김정배;김민수;송원표;김덕수;전찬석;길경석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권1호
    • /
    • pp.22-30
    • /
    • 2002
  • ln this paper, it was reported the developed results of the monitoring unit for 72.5kY GIS which it is one part of the monitoring system for the substation that Korea Railway Company is promoting. In order to monitor the operational status of GIS, four parameters were chosen: the number of times of the circuit breaker switching, tightness of the gas-sealed units (circuit breaker / disconnecting switch / earthing switch), the number of times of the lightning arrestor operating and the leakage current of the lighting arrester. We constructed the monitoring system that can be judged the operating condition of the GIS from the signal of the suitable sensor for the purpose. Therefore, it is possible to on line monitoring for the condition of the GlS without efforts of the Periodic inspection.

도시철도 변전소 절연진단 프로그램 기술 분석 (An Analysis on Technology of Urban Railway Substation Insulation Diagnostic Program)

  • 박현준;박영;정호성;김형철;유기선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.116-116
    • /
    • 2010
  • This paper introduces an comprehensive monitoring and management program for implementation of a real-time monitoring system that monitors condition of urban railway AC/DC transformers, disconnecting switches, circuit breakers, regulators, and GIS (Gas Insulated Switchgear). Especially, the system is applied to diagnose the overall condition of urban railway substations by sending acquired data through an OPC server to a database, effectively storing and monitoring conditions simultaneously. The above system is a management based system and is also applicable to small-scale systems.

  • PDF

도시철도 변전소 전력설비 실시간 모니터링 방안 도출 (Derivation of Real-time Monitoring System for Power Supply System in Metro Substation)

  • 정호성;박영;어수영
    • 한국전기전자재료학회논문지
    • /
    • 제23권4호
    • /
    • pp.333-337
    • /
    • 2010
  • This paper introduces an overall system design of a real-time monitoring system that monitors condition of urban railway AC/DC transformers, disconnecting switches, circuit breakers, regulators, and GIS (gas insulated switchgear). For effective diagnosis of urban railway facilities we developed optimized sensors and application technology. The proposed system is combined with wireless technology, implementing remote real-time monitoring of urban railway facilities. The derived real-time monitoring system for power facilities in urban railway substations will be applied not only to diagnose low voltage DC (direct current) railways but also to diagnose design of small power facilities of skyscrapers and apartments.

GIS에 있어서의 과도과전압(過渡過電壓) 측정용(測定用) 센서 (A Voltage Sensor for measurement of Very Fast Transients in GIS)

  • 이복희;백용현;하촌달치;서촌준언;석정승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.297-300
    • /
    • 1990
  • The measurement of very fast transients generated by disconnecting switches in gas-insulated switchgear(GIS) have to deal with the problems such as reliability, interference pich-up, optimal design of high voitage equipments. This paper presents a new developed voltage sensor to measure the very fast transients, the basic theory of the measuring method, the design, structure of planar capacitive voltage probe are described. Finally the examples of modelling tests on an actual site GIS are discussed.

  • PDF

신경회로망을 이용한 GIS용 단로기의 이상신호 패턴분석 (Fatten Analysis of Trouble Signal on DS for GIS using Neural Network)

  • 김종서;이은석;천종철
    • 한국전기전자재료학회논문지
    • /
    • 제16권12S호
    • /
    • pp.1310-1315
    • /
    • 2003
  • GIS(Gas Insulated Switchgear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. But, because of structural characteristics, this is difficult to monitor externally and provide much loss in the event of an accident. Recently, because equipment of GIS is occurring problem of confidence used for a long time, development of diagnosis technique have been importantly recognized. therefore, measurement and analysis of PD much has been generally used for equipment of GIS. But, in case of measurement of PD at field, real trouble signals is difficult to classify noise. Accordingly, a variety of trouble conditions for DS are simulated, and detected signals are analyzed by the application of electrical and mechanical methods. For this analysis, detected signals are accumulated according to phase-magnitude with the application of induction sensor, and then we analyzed the characteristics. For the simulation experiment, we make DS for 170KV GIS and analyze the characteristics of detected signals with the application of neural network algorithm. last, we have measured DS for GIS at field, and then have analyzed detected signals.