• 제목/요약/키워드: Discharging process

검색결과 188건 처리시간 0.029초

NKN 무연압전 액추에이터의 신뢰성 연구 (An Investigation on the Aging Properties of NKN Lead-free Piezoelectric Multi-layer Ceramic Actuators)

  • 채문순;이규탁;고중혁
    • 한국전기전자재료학회논문지
    • /
    • 제24권10호
    • /
    • pp.803-806
    • /
    • 2011
  • 1 mol% $Li_2O$ excess $0.9(Na_{0.52}K_{0.48})NbO_3-0.1LiTaO_3$ lead-free piezoelectric multilayer ceramic actuators were investigated to determine their aging properties. To reduce the thermal aging behavior, we applied a rectified unipolar electric field of 5 kV/mm to the specimen to accelerate the electric aging behavior. By employing a rectified unipolar electric field for the piezoelectric actuators, we could remove undesirable heating from the relaxation current in the motion of the ferroelectric domain. To accelerate the aging test, the applied electric fields had a frequency of 900 Hz. To have enough time for charging and discharging, we employed an accurate time constant to design the equivalent circuit model for the aging tester. To extract exact aging behavior, we measured the pseudo-piezoelectric coefficient before and after the aging process. We also measured the electro-mechanical coupling coefficient, the frequency-dependent dielectric permittivity, and the impedance to compare with fresh and aged specimen.

고주파해동기 개발에 관한 연구 (A Study on Development of the High Frequency Thawing Machine)

  • 정석봉;김태훈;손태영;유응성;신지영;정재연;황진우;양지영
    • 한국산업융합학회 논문집
    • /
    • 제21권6호
    • /
    • pp.301-307
    • /
    • 2018
  • This paper deals with the development of the high frequency thawing machine. The fishery products caught over the world are kept frozen to maintain freshness. These fishery products require thawing before they are sold to customers as food. However, the thawing process can cause freshness reduction, drip coming out, quality deterioration, discharging polluted water, as well as a lot of space and time. The high frequency thawing machine developed to solve this problem has a narrow space, a short thawing time and a small drip. The developed high frequency thawing machine can be used in many fields such as fish processing plant, livestock processing plant. This paper describes the design of the high frequency thawing machine by developing the high frequency generator, development of the controller, and the design of mechanism, and shows the superiority of the high frequency thawing machine by the performance evaluation.

Estimation of Hovering Flight Time of Battery-Powered Multicopters

  • Cho, Mun jin;Han, Cheolheui
    • 항공우주시스템공학회지
    • /
    • 제15권4호
    • /
    • pp.11-20
    • /
    • 2021
  • The estimation of hovering flight time of multicopters using the battery power propulsion system is important for the development and design of the aircraft and its operation. For a given operational weight, the maximum possible battery weight can be decided using both a conventional energy density method and a new Peukert law. In the present study, the hovering flight time is predicted using both methods. The specific data of multicopters in the published literatures were employed for the computation of the hovering flight time. The results were validated with the measured data. The effect of figure of merit of propeller, battery discharging process on the hovering flight time was evaluated, Finally, the effect of the battery cell and package connection types on the hovering time was investigated. It was found that the combination of serial battery cell connections and parallel package connection is the bast in the endurance maximization aspect. As the cell number increases in a package, the hovering flight time is increased. There exists the max. battery ratio for the given takeoff gross weight.

상변화물질과 맥동형 히트 파이프를 이용한 배터리 열 관리 시스템에 대한 수치해석적 연구 (Numerical study on battery thermal management system using phase change material with oscillating heat pipe)

  • 박승현;추민기;손동기;고한서
    • 한국가시화정보학회지
    • /
    • 제22권2호
    • /
    • pp.104-114
    • /
    • 2024
  • To effectively control heat generation resulting from advancements in fast discharging technology for electric vehicle batteries, hybrid Battery Thermal Management Systems (BTMS) are gaining attention. In this study, a BTMS combining Phase Change Material (PCM) with Oscillating Heat Pipe (OHP) was designed. During the phase change process of the PCM, the maximum battery temperature increased slowly. Additionally, due to the excellent heat transfer capability of the OHP, the PCM/OHP BTMS delayed the time when the maximum battery temperature exceeded 50 ℃ by 810 s compared to the PCM/copper fin BTMS, resulting in the maximum battery temperature that was 41.29 ℃ lower at 3600 s. Furthermore, in the section where the latent heat of the PCM had the greatest impact, the slope of the battery temperature difference was 0.0017 lower than that of the PCM/copper fin BTMS. Therefore, the PCM/OHP BTMS demonstrates its potential as a viable hybrid BTMS.

의료서비스의 과정적 질과 잠재적으로 예방 가능한 재입원율과의 관계 (Does Process Quality of Inpatient Care Serve as a Guide to Reduce Potentially Preventable Readmission (PPR)?)

  • 최재영
    • 한국병원경영학회지
    • /
    • 제23권1호
    • /
    • pp.87-106
    • /
    • 2018
  • Purpose: 본 연구는 미국 캘리포니아와 플로리다에 위치한 의료기관을 대상으로 급성심근경색증, 심부전, 폐렴을 주진단으로 받은 메디케어 입원환자들에게 제공된 의료서비스의 과정적 질과 잠재적으로 예방이 가능한 30일 이내 위험 보정 재입원율과의 관계를 살펴보았다. Methods: 본 연구의 종속변수는 잠재적으로 예방이 가능한 30일 이내 위험 보정 질환별 재입원율이며 3M PPR 소프트웨어를 이용하여 재입원의 예방 가능 여부를 결정하였다. 미연방 의료 비용 및 이용 프로젝트 데이터베이스, 미국병원협회의 병원조사 자료, 미연방 보건복지부소속 메디케어 및 메디케이드 서비스 센터의 병원비교 자료를 이용하였다. 자료의 위계적 구조를 고려하여 다수준 로지스틱 회귀분석을 이용하여 분석하였다. Findings: 의료서비스의 과정적 품질과 퇴원 후 30일 이내 잠재적 예방 가능 위험도 보정 재입원율과의 관계는 질환별로 차이를 보였다. 폐렴의 경우 의료서비스의 과정적 질은 30일 이내 잠재적 예방 가능 보정 재입원율과 유의한 부(-)의 관계를 보였으나, 급성심근경색증과 심부전의 경우 대체로 유의한 관계를 관찰할 수 없었다. Practical Implications: 잠재적으로 예방 가능한 급성심근경색증, 심부전 재입원율을 줄이기 위해서는 의료기관에서 가이드라인으로 따를 수 있는 더욱 다양한 근거 중심의 과정적 질 지표의 개발에 대한 정부와 보건의료계의 노력이 필요하다.

Sand-Blasting법을 이용한 활물질/기판간 결합력 향상에 따른 AGM 연축전지의 성능 및 충방전 거동 (Performance and Charging-Discharging Behavior of AGM Lead Acid Battery according to the Improvement of Bonding between Active Material/Substrate using Sand-Blasting Method)

  • 김성준;임태섭;김봉구;손정훈;정연길
    • 한국재료학회지
    • /
    • 제31권2호
    • /
    • pp.75-83
    • /
    • 2021
  • To cope with automobile exhaust gas regulations, ISG (Idling Stop & Go) and charging control systems are applied to HEVs (Hybrid Electric Vehicle) for the purpose of improving fuel economy. These systems require quick charge/discharge performance at high current. To satisfy this characteristic, improvement of the positive electrode plate is studied to improve the charge/discharge process and performance of AGM(Absorbent Glass Mat) lead-acid batteries applied to ISG automotive systems. The bonding between grid and A.M (Active Material) can be improved by applying the Sand-Blasting method to provide roughness to the surface of the positive grid. When the Sand-Blasting method is applied with conditions of ball speed 1,000 rpm and conveyor speed 5 M/min, ideal bonding is achieved between grid and A.M. The positive plate of each condition is applied to the AGM LAB (Absorbent Glass Mat Lead Acid Battery); then, the performance and ISG life characteristics are tested by the vehicle battery test method. In CCA, which evaluates the starting performance at -18 ℃ and 30 ℃ with high current, the advanced AGM LAB improves about 25 %. At 0 ℃ CA (Charge Acceptance), the initial charging current of the advanced AGM LAB increases about 25 %. Improving the bonding between the grid and A.M. by roughening the grid surface improves the flow of current and lowers the resistance, which is considered to have a significant effect on the high current charging/discharging area. In a Standard of Battery Association of Japan (SBA) S0101 test, after 300 A discharge, the voltage of the advanced AGM LAB with the Sand-Blasting method grid was 0.059 V higher than that of untreated grid. As the cycle progresses, the gap widens to 0.13 V at the point of 10,800 cycles. As the bonding between grid and A.M. increases through the Sand Blasting method, the slope of the discharge voltage declines gradually as the cycle progresses, showing excellent battery life characteristics. It is believed that system will exhibit excellent characteristics in the vehicle environment of the ISG system, in which charge/discharge occurs over a short time.

계통 연계 PV-ESS 확장성 확보를 위한 병렬 DC-모듈형 PCS 설계 (The bidirectional DC module type PCS design for the System Inter Connection PV-ESS of Secure to Expandability)

  • 황락훈;나승권;최병상
    • 한국정보전자통신기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.56-69
    • /
    • 2021
  • 상용계통과 연계한 PV 시스템은 인버터의 특성과 더불어 소형, 고 역률, 낮은 고조파 출력, 고 신뢰성, 최대출력 운전, 저비용 등의 장점이 요구된다. 태양광발전시스템의 PV 에너지를 계통과 부하로 전달하기 위해 양방향의 PCS가 요구되어 진다. 본 논문에서는 태양광 발전의 ESS를 고려한 PCS를 제안하여 부하평준화를 통한 전력의 안정적인 공급을 확인하고자 한다. 이를 위해 일사량과 부하량에 따른 5단계의 동작 모드 알고리즘을 제안하고, 충/방전 제어를 위한 제어기를 설계 하였다. 양방향의 효율적인 에너지 전달을 위해 DC-link단에 양방향 컨버터 및 배터리를 연결하고, 연계형 인버터를 통해 DC-link 전압 및 인버터 출력전압을 제어하였다. 제안된 시스템의 타당성을 입증하기 위해 PSIM을 사용한 시뮬레이션을 수행하여 타당성과 안정성을 검토하였으며, 이를 확인하기 위해 3[kW] PCS를 제작하여 실험하였다. 실험결과를 통해 제안된 시스템에 요구되어지는 특성을 검증하였으며 기존 시스템에 비해 강인한 시스템을 구성하였다.

퇴원 의지가 요양병원의 성공적 퇴원에 미치는 영향에 대한 다수준 분석 (A Multilevel Analysis about the Impact of Patient's Willingness for Discharge on Successful Discharge from Long-term Care Hospitals)

  • 강하렴;이연주
    • 보건행정학회지
    • /
    • 제32권4호
    • /
    • pp.347-355
    • /
    • 2022
  • Background: Since November 2019, long-term care hospitals have been able to provide patients with discharging programs to support the elderly in the community. This study aimed to identify both patient- and hospital-level factors that affect successful community discharge from long-term care hospitals. Methods: A multilevel logistic regression model was performed using hospitals as a clustering unit. The dependent variable was whether a patient stayed in the community for at least 30 days after discharge from a long-term care hospital. As for the patient-level independent variables, an agreement between a patient and the family about discharge, length of hospital stay, patient category, and residence at discharge were included. The number of beds and the ratio of long-stay patients were selected for the hospital-level factors. The sample size was 1,428 patients enrolled in the discharging program from November 2019 to December 2020. Results: The number of patients who were discharged to the community and stayed at least for 30 days was 532 (37.3%). The intraclass correlation coefficient was 22.9%, indicating that hospital-level factors had a significant impact on successful community discharge. The odds ratio (OR) of successful community discharge increased by 1.842 times when the patients and their families agreed on discharge. The ORs also increased by 3.020 or 2.681 times, respectively when the patients planned to discharge to their own house or their child's house compared to those who didn't have a plan for residence at discharge. The ORs increased by 1.922 or 2.250 times when the hospitals were owned by corporate or private property compared to publicly owned hospitals. The ORs decreased by 0.602 or 0.520 times when the hospital was sized over 400 beds or located in small and medium-sized cities compared to less than 200 bedded hospitals or located in metropolitan cities. Conclusion: The results of the study showed that the patients' and their family's willingness for discharge had a great impact on successful community discharge and the hospital-level factors played a significant role in it. Therefore, it is important to acknowledge and support long-term care hospitals to involve active in the patient discharge planning process.

금속수소화물 수소 저장 용기 내부의 수소방출에 대한 수치해석적 연구 (Numerical Study of Hydrogen Desorption in a Metal Hydride Hydrogen Storage Vessel)

  • 강경문;남진무;유하늘;주현철
    • 한국수소및신에너지학회논문집
    • /
    • 제22권3호
    • /
    • pp.363-371
    • /
    • 2011
  • In this paper, a three-dimensional hydrogen desorption model is developed to precisely study the hydrogen desorption kinetics and resultant heat and mass transport phenomena in metal hydride hydrogen storage vessels. The metal hydride hydrogen desorption model, i.e. governed by the conservation of mass, momentum, and thermal energy is first experimentally validated against the temperature evolution data measured on a cylindrical $LaNi_5$ metal hydride vessel. The equilibrium pressure used for hydrogen desorption simulations is derived as a function of H/M atomic ratio and temperature based on the experimental data in the literature. The numerical simulation results agree well with experimental data and the 3D desorption model successfully captures key experimental trends during hydrogen desorption process. Both the simulation and experiment display an initial sharp decrease in the temperature mainly caused by relatively slow heat supply rate from the vessel external wall. On the other hand, the effect of heat supply becomes influential at the latter stages, leading to smooth increase in the vessel temperature in both simulation and experiment. This numerical study provides the fundamental understanding of detailed heat and mass transfer phenomena during hydrogen desorption process and further indicates that efficient design of storage vessel and heating system is critical to achieve fast hydrogen discharging performance.

고도산화공정을 이용한 반응성 염료의 제거 및 생태독성 저감 (Degradation and Ecotoxicity Reduction of Reactive Dye by Using Advanced Oxidation Process)

  • 서경애;박재홍;정수정;임병진
    • 한국물환경학회지
    • /
    • 제29권2호
    • /
    • pp.204-211
    • /
    • 2013
  • In this study, the deriving optimum conditions for decolorization of Acid Orange II solution was carried using $TiO_2$ advanced oxidation process. After that, on base of the deriving results, the range of dye concentration was estimated. In addition, acute toxicity test was also carried to assess toxicity unit according to decolorization and TOC removal. In case of the blockage of light, 20 mg/L of dye solution, and 0.5 g $TiO_2$, the effect of decolorization at pH 3 was larger than at pH 6 and 10, so it was shown that decolorization is dependent on pH. The use of 5 g $TiO_2$ showed best performance of decolorization, but that of 3 g $TiO_2$ was chosen to optimum condition in considering of economical aspects. Four light sources, sun, fluorescent lamp, BLB lamp, and UV-B lamp, were used and decolorization was 99.4% and 100% at 50 mg/L, 98.6% and 99.7% at 100 mg/L for sun and UV-B lamp, respectively. In spite of the optimum condition of decolorization at pH 3, the evaluation of acute toxicity test showed highly toxic. In conclusion, although the optimum treatment of dye solution is performed, water ecology can be polluted in discharging it into water system. Therefore, it is needed to study of water ecological system with dye water treatment, and it takes all the circumstances into consideration.