• Title/Summary/Keyword: Discharging

Search Result 1,171, Processing Time 0.031 seconds

Minimizing Empty Trips of Yard Trucks in Container Terminals by Dual Cycle Operations

  • Nguyen, Vu Duc;Kim, Kap-Hwan
    • Industrial Engineering and Management Systems
    • /
    • v.9 no.1
    • /
    • pp.28-40
    • /
    • 2010
  • One of the most important objectives of the schedules in a container terminal is to minimize the ship operation time, which consists of discharging and loading operation times. Recently, dual cycling techniques have been used for improving terminal operations, especially for reducing the total empty trips of handling equipment. The main focus of this study is to reduce the empty trip times of yard trucks with minimum delays for ship operations. A heuristic algorithm, modified from a previous algorithm, is proposed to solve this problem. A simulation study is conducted to evaluate the effect of different types of discharging and loading schedules and different locating methods for discharging containers in terms of the performance of the system, including the percentage of the dual cycle operations of yard trucks.

The EMTP Analysis and Characteristics of Load Impedance on Various Electrode length, Pulse Repetition in Pulse Corona Discharging (펄스코로나 방전의 전극길이, 펄스반복율에 따른 부하 임피던스 변화 특성 및 EMTP 해석)

  • Jeong, Jong-Han;Song, U-Jeong;Jeon, Jin-An;Jeong, Hyeon-Ju;Hong, Jeong-Hwan;Kim, Hui-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.4
    • /
    • pp.158-163
    • /
    • 2002
  • The pulsed Power system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, often generator, etc. In this paper, we study EMTP analysis and characteristics of critical voltage and load in impedance on various electrode length of pulse corona. To obtain a stable pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a re sult, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.

Low-cost crowbar system and protection scheme in capacitor bank module (커패시터 뱅크 모듈 구성에 있어서 경제적인 크로바 시스템과 보호회로)

  • Rim, Geun-Hie;Cho, Chu-Hyun;Lee, Hong-Sik;Pavlov, E.P.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2089-2091
    • /
    • 2000
  • Pulsed power systems consist of a capacitor bank, an isolated high-voltage charging power-supply, high-current bus-work for charging and discharging and a control system. In such pulsed power systems, the operating-lifetime of the capacitors is closely dependent on the voltage reversal. Hence, most capacitor-discharging systems includes crowbar circuits. The crowbar circuit prevents the capacitor recharging with reverse voltage. Usually it consists of crowbar resistors and high pulse-current diode-stacks connected in series. The requirements for the diode-stacks are fast-recovery time and high-voltage and large-current ratings, which results in the high cost of the pulsed-power system. This paper presents a protection scheme of a charging and discharging system of a 500kJ capacitor bank using a low-cost crowbar circuit and safety-fuses.

  • PDF

A Study on the discharging behavior of food wastes in household (가정의 음식폐기물 배출행동 및 관련 변인에 관한 연구)

  • 최남숙;임창희
    • Journal of Family Resource Management and Policy Review
    • /
    • v.5 no.2
    • /
    • pp.87-98
    • /
    • 2001
  • The study was to examine the effect on the thinking of environmental preservation and behavior of dietary life control on discharging behavior of food wastes in household. The data were obtained from 443 homemakers living in Seoul. The statistical techniques used for this study included descriptive statistics, ANOVA, and Multiple Regression Analysis. As the result of analyzing relative effects of factors on discharging behavior of food wastes, for the degree of separation and discharge of food wastes and general wastes, they further actively separated and discharged them when they lived in public house(apartment, villa, tenement house), they had direct charge of dietary life, they had further serious thinking of environmental preservation, and they lived further diligent lives.

  • PDF

Charging-Discharging System with High Power Factor, High Efficiency (고역률, 고효율 충.방전기)

  • Kim, Eun-Soo;Joe, Kee-Yeon;Byun, Young-Bok;Koo, Heun-Hoi
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.371-375
    • /
    • 1995
  • This paper presents equipment for charging and discharging with high power factor and high efficiency. This equipment is consisted of $3{\phi}$ SPWM AC/DC converter for improving input current waveform and input power factor, and bidirectional DC/DC converter for electric isolation in the DC link Part. Therefore, Input power factor and the total efficiency in the proposed system can be increased more than in the conventional phase-controlled thyristor charging-discharging System.

  • PDF

A Study of the Supersonic Free Jet Discharging from a Petal Nozzle (Petal 노즐로부터 방출되는 초음속 자유제트 유동에 관한 연구)

  • Lee Jun-Hee;Kim Jung-Bae;Kim Heuy-Dong
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.109-112
    • /
    • 2002
  • The supersonic jet discharging from a petal nozzle is known to enhance mixing effect with the surrounding gas because it produces strong longitudinal vortices due to the velocity difference from both the major and minor axes of petal nozzle. In the present study, the supersonic free jet discharging from the petal nozzle is investigated experimentally. The nozzles used are 4, 6, and 8 lobed petal nozzles with a design Mach number of 1.7, and the flow fields are compared with a circular nozzle with the same design Mach number. The pitot impact pressures are measured using a fine pilot probe. The flow fields are visualized using a Schlieren optical method. The results show that the petal nozzle has more increased supersonic length compared with the circular jet.

  • PDF

Recent Progress in Dielectric-Based Ultrafast Charging/Discharging Devices (유전체를 활용한 초고속 에너지 충/방전 소자 기술)

  • Choi, Hyunsu;Ryu, Jungho;Yoon, Woon-Ha;Hwang, Geon-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.4
    • /
    • pp.322-332
    • /
    • 2022
  • Energy storage capacitors based on dielectric ceramics with superior polarization properties and dielectric constant can provide much higher output power density due to their very fast energy charging/discharging rates, which are particularly suitable for operating pulsed-power devices. For an outstanding energy storage performance of dielectric capacitor, a large recoverable energy density could be derived by introducing a slim polarization-electric field hysteresis loop into dielectric materials by various technical approaches. Many research teams have explored various dielectric capacitor technologies to demonstrate high output power density and ultrafast charging/discharging behavior. This article reviews the recent research progress in high-performance dielectric capacitors for pulsed-power electronic applications.

A Study on Chargin and Discharging Characteristics of Variable Volume with Compressed Air (가변체적내의 압축공기 충진 및 방출특성연구)

  • Kim, Dong-Soo;Kim, Hyoung-Eui;Park, Jae-Bum;Kang, Bo-Sig;Sung, Baek-Ju
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.11
    • /
    • pp.125-131
    • /
    • 1995
  • Pneumatic System has been mainly used as main equipment for actuation and control of fluid force in manufacturing industry. For velocity control of piston, meter-out restriction method is used in many cases. In this systems, meter-out restriction method is adopted for analysing the Dynamic Charging and Discharging Process which is Variable Volume Chamber. Experiments has been conducted for different supply pressure condition. As a experimental result, charge side chamber pressure rises to supply pressure rapidily and discharge side chamber pressure decreases. Also, when the air in the cylinder is discharged, tempdrature of air decreases steeply. Restriction of the Cylinder sometimes freeze and it dose not function. The result will be useful for the analysis of pneumatic system.

  • PDF

Pneumatic Separation on Separating Unit of a Combine Harvester (콤바인 선별실(選別室)의 기류선별(氣流選別)에 관한 연구(硏究))

  • Chung, C.J.;Nam, S.I.;Joo, B.C.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.3
    • /
    • pp.32-43
    • /
    • 1988
  • This study was attempted to investigate the pneumatic separation on separating unit of a combine harvester. The aerodynamic characteristics of threshed materials were analyzed by experiments. The air velocity distribution within the separation chamber was measured for various speeds of the winnower and suction fans to find out the operational and design conditions of the separating unit which would serve for reducing the grain loss from chaff outlet. The results of study arc summarized as follows: 1. Based on the separation curve of threshed materials analyzed, it was shown that three different kind. of materials-kernels, straw chaff, and leaf chaff were as a whole able to be separated pneumatically, regardless of varieties. However, a small amount of the separation grain loss may be expected to occur if the complete separation between kernels and straw chaff would be undertaken because some portion of their separation curve were overlapping. 2. The analysis of air velocity distribution showed that the separation chamber may be divided into two regions, the discharging and separating. The air velocity of the discharging region was 5-15 m/s and that of the separating region 2-5 m/s. 3. The air movement of the separation chamber may be a turbulence flow, being its speed became greater as it moves from the left to the right section of the separation chamber. The equi-speed line. of air flow had a steep gradient in between the discharging and the separation regions. The air velocity in the discharging region was much higher than the terminal velocity of kernels, because of which those kernels appearing in the region could be possibly exhausted as the grain loss from the chaff outlet. 4. The motion trajectory of threshed material in the separating region was dominantly affected by the winnower fan, on the other hand, its motion in the discharging region was affected by suction fan. 5. The grain loss from the chaff outlet was affected greatly by the winnower fan and the trace of kernel movement. It was observed that the optimum working speed to give minimum grain loss from chaff outlet for the combine tested should be maintained at 950~1,150 rpm for the winnower fan and 1,850 rpm for the suction fan. 6. It was shown that a large portion of grain loss from chaff outlet may occur when the kernels may bump against a portion of separation chamber wall and those kernels thus scattered into the discharging region were sucked by the suction fan. It was accordingly recommended that a new design of the wall of separation chamber so as to bump down kernels may be necessary to reduce grain loss from the chaff outlet.

  • PDF

A 15kW Grid-Connected Battery Charging and Discharging System with AC Regeneration Function

  • Youn, Sun-Jae;Kim, Jun-Gu;Kim, Jae-Hyung;Won, Chung-Yuen;Na, Jong-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.491-493
    • /
    • 2011
  • In this paper, a 15kW grid-connected battery charging and discharging system was proposed. AC regenerative device which consisted of an inverter using IGBTs and LCL filter transferred surplus power to grid. Phase locked loop(PLL) was used to resolve three-phase unbalance. AC regeneration function is able to improve the rate of energy use and the cost savings of energy is expected.

  • PDF