• Title/Summary/Keyword: Discharging

Search Result 1,177, Processing Time 0.031 seconds

Review on hazardous microcystins originating from harmful cyanobacteria and corresponding eliminating methods (유해 남세균 유래 마이크로시스틴의 위해성과 제거 방안 고찰)

  • Sok Kim;Yoon-E Choi
    • Korean Journal of Environmental Biology
    • /
    • v.41 no.4
    • /
    • pp.370-385
    • /
    • 2023
  • Cyanobacterial harmful algal blooms (Cyano-HABs) are an international environmental problem that negatively affects the ecosystem as well as the safety of water resources by discharging cyanotoxins. In particular, the discharge of microcystins (MCs), a highly toxic substance, has been studied most actively, and various water treatment methods have been proposed for this purpose. In this paper, we reviewed adsorption technology, which is recognized as the most feasible, economical, and efficient method among suggested treatment methods for removing MCs. Activated carbons (AC) are widely used adsorbents for MCs removal, and excellent MCs adsorption performance has been reported. Research on alternative adsorption materials for AC such as biochar and biosorbents has been conducted, however, their performance was lower compared to activated carbon. The impacts of adsorbent properties(characteristics of pore surface chemistry) and environmental factors (solution pH, temperature, natural organic matter, and ionic strength) on the MCs adsorption performance were also discussed. In addition, toward effective control of MCs, the possibility of the direct removal of harmful cyanobacteria as well as the removal of dissolved MCs using adsorption strategy was examined. However, to fully utilize the adsorption for the removal of MCs, the application and optimization under actual environmental conditions are still required, thereby meeting the environmental and economic standards. From this study, crucial insights could be provided for the development and selection of effective adsorbent and subsequent adsorption processes for the removal of MCs from water resources.

A Study on the Livestock Resources regarding on the Discharging Characteristics from Farm Land (농지 주입 시 배출특성에 대한 축분자원화물 연구)

  • Lim, Jai-Myug;Lee, Young-Sin;Han, Gee-Bong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.4
    • /
    • pp.91-102
    • /
    • 2009
  • In this study, to estimate the transforming (runoff and leachate) rate of the organic fertilizer made of livestock resources to farm land, laboratory scale test was conducted and the results were obtained as follows: The runoff volume from farm land showed the tendency of increase according to the increase of rainfall intensity. The most rainfall leachated into the underground at the rainfall intensity of 20mm/hr, and rainfall of 5L or less leachated at the rainfall intensity of > 32.4 mm/hr. This shows that surface runoff largely depends on the rainfall intensity when soil characteristic and hardness are similar in each site. When liquid compost was fertilized, the surface runoff was similar with the results from the reactor fertilized by compost, and leachate flow was found to be lower than compost. The runoff ratio of contaminant parameters from farm land were BOD 0.00003,, $COD_{cr}$ 0.00006, TN 0.00056, TP 0.00011, TOC 0.00005, Especially, the runoff ratio of TN showed 10 folds higher than other parameters. On the other hand, the runoff ratio of SS showed higher value of 0.001, and colloid particles of soil caused this result rather than the leachate from compost fertilizer. At all ranges of rainfall intensity, fertilizer removal ratio by farm land was found to be 94.9~98.4% for compost and 85.8~98.1% for liquid compost in terms of BOD. For TN, it resulted in 96.6~98.4% for compost and 97.2~98.5% for liquid compost, and thus the most fertilizer from livestock resources were shown to be reduced through farm land application.

Pebble flow in the HTR-PM reactor core by GPU-DEM simulation: Effect of friction

  • Zuoyi Zhang;Quan Zou;Nan Gui;Bing Xia;Zhiyong Liu;Xingtuan Yang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3835-3850
    • /
    • 2024
  • The high-temperature gas-cooled reactor (HTGR) with spherical fuel elements contains complex pebble flow. The flow behavior of pebbles is influenced by various factors, such as pebble density, friction coefficient, wall structure, and discharge port size. Using a GPU-DEM numerical model, the effects of the friction coefficient on the cyclic loading and unloading of pebbles in the full-scale HTR-PM are studied. Numerical simulations with up to 420,000 spherical pebbles are conducted. Four sets of friction coefficient values are determined for comparative analysis based on experimental measurements. Discharging speed, residence time, stress, porosity, and velocity distribution are quantitatively analyzed. In addition, a comparison with the CT-PFD experiment is carried out to validate the numerical model. The results show that near-wall retention phenomena are observed in the reactor core only when using large friction coefficients. However, using friction coefficient values closer to the measured experimental values, the pebble bed in HTR-PM exhibited good flow characteristics. Furthermore, the friction coefficient also influences the porosity and velocity distribution of the pebble bed, with lower friction coefficients resulting in lower overall stress in the bed. The discharge outlet's influence varies with different friction coefficient values. In summary, this study demonstrates that the value of the friction coefficient has a complex influence on the pebble flow in HTR-PM, which provides important insights for future numerical and experimental studies in this field.

Secondary Battery Electrode Material for Next Generation Mobility Power Storage (차세대 모빌리티 전력 저장 이차전지 핵심소재)

  • Yu-Jin Song;Seo-Hyun Kim;Se-Jin Kim;Jae Hoon Kim
    • Clean Technology
    • /
    • v.30 no.3
    • /
    • pp.159-174
    • /
    • 2024
  • The rapid increase in energy consumption based on fossil fuels is accelerating global warming. In particular, the road transportation sector has high carbon dioxide emissions, so transitioning towards electric vehicles is recommended. Thus, the importance of secondary batteries is increasing. Secondary batteries are reversible batteries that use energy and can be reused through a charging and discharging process. Currently, lithium-ion batteries are widely used. Secondary batteries place importance on six major factors: energy, output, lifespan, environmental friendliness, cost, and stability. Research is actively being conducted to satisfy all six factors by understanding the material characteristics of each component of the battery. As it is difficult to move away from lithium as a cathode material, researchers are investigating higher performance materials that mix materials such as cobalt, nickel, manganese, and aluminum with lithium and use graphite, silicon, and lithium metal to increase capacity. In the case of electrolytes, liquid electrolytes are still mainly used. However, solid electrolytes are being studied due to their stability, but additional research must be conducted to satisfy the energy and output factors. This review paper aims to provide an understanding of secondary batteries through an overview of secondary batteries, the materials and characteristics of their components, their technological trends, and their associated companies.

Characteristics of Fish Fauna Collected from Near Estuaries Bank and Fish-way on the Bank of Naktong River (낙동강 하구둑 수역의 어류 군집구조와 어도 이용 어류)

  • Kang, Eon-Jong;Yang, Hyeon;Lee, Heung-Hun;Kim, Kwang-Sug;Kim, Chi-Hong
    • Korean Journal of Ichthyology
    • /
    • v.24 no.3
    • /
    • pp.201-219
    • /
    • 2012
  • The estuaries bank of Nakdong River, Korea, was constructed in 1987 and many arguments have been under discussion on the subject of ecological impact on ecosystem during 20 years. In this context, however, it was not focused on the role of fish-way and the way of improvement to promote fish movement to complete its life history. This paper was the result of investigation on fish fauna of upper and lower part of the bank and the analysis of comparison of the fishes with those using fish-way which were installed in each side of bank as ladder type and fish gate. The authors discussed the importance of fish gate and its management base on the result. The number of fishes collected in this study for upper part of estuaries bank was 31 species, among them 71% was the pure freshwater residents indicating the characteristics of the area as a freshwater ecosystem. It was observed that 9 species of coastal fishes were found in this region including Coilia ectens and Neosalanx sp. which is anadromous to spawn. Excluding 6 freshwater fishes, 30 fish species collected in lower part of estuaries bank were coastal fishes indicating that former brackish ecosystem was changed into marine one. The freshwater fishes found in this region were restricted the appearance only in the season of discharging freshwater into the sea. The number of fishes found in fish-way was 39 species, more than that of river and coast. But only 19 species founded in fish ladder was comparable with the result of investigation on fish gate including 32 species. It was considered that the fish gate has more important role as a fish passage from the fact that only it allowed to movement of numerous number of fry of Neosalanx sp. and Engraulis japonicus. These results indicates that two-way movement system is more efficient than downward only one in estuaries bank for fish migration.

Thermal Effluent Effects of Domestic Sewage and Industrial Wastewater on the Water Quality of Three Small Streams (Eung, Chiljang and Buso) during the Winter Season, Korea (동계 저온기의 소하천 수질에 미치는 하·폐수의 온배수 영향)

  • Soon-Jin, Hwang;Jeon, Gyeonghye;Eum, Hyun Soo;Kim, Nan-Young;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.2
    • /
    • pp.238-253
    • /
    • 2017
  • The sewage and wastewater (SAW) are a well-known major source of eutrophication and greentide in freshwaters and also a potential source of thermal pollution; however, there were few approaches to thermal effluent of SAW in Korea. This study was performed to understand the behavioral dynamics of the thermal effluents and their effects on the water quality of the connected streams during winter season, considering domestic sewage, industrial wastewater and hot spring wastewater from December 2015 to February 2016. Sampling stations were selected the upstream, the outlet of SAW, and the downstream in each connected stream, and the water temperature change was monitored toward the downstream from the discharging point of SAW. The temperature effect and its range of SAW on the stream were dependent not only on the effluent temperature and quantity but also on the local air temperature, water temperature and stream discharge. The SAW effects on the stream water temperature were observed with temperature increase by $2.1{\sim}5.8^{\circ}C$ in the range of 1.0 to 5.5 km downstream. Temperature effect was the greatest in the hot spring wastewater despite of small amount of effluent. The SAW was not only related to temperature but also to the increase of organic matter and nutrients in the connected stream. The industrial wastewater effluent was discharged with high concentration of nitrogen, while the hot spring wastewater was high in both phosphorus and nitrogen. The difference between these cases was due to with and without chemical T-P treatment in the industrial and the hot spring wastewater, respectively. The chlorophyll-a content of the attached algae was high at the outlet of SAW and the downstream reach, mostly in eutrophic level. These ecological results were presumably due to the high water temperature and phosphorus concentration in the stream brought by the thermal effluents of SAW. These results suggest that high temperature of the SAW needs to be emphasized when evaluating its effects on the stream water quality (water temperature, fertility) through a systematized spatial and temporal investigation.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

A SOC Coefficient Factor Calibration Method to improve accuracy Of The Lithium Battery Equivalence Model (리튬 배터리 등가모델의 정확도 개선을 위한 SOC 계수 보정법)

  • Lee, Dae-Gun;Jung, Won-Jae;Jang, Jong-Eun;Park, Jun-Seok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.99-107
    • /
    • 2017
  • This paper proposes a battery model coefficient correction method for improving the accuracy of existing lithium battery equivalent models. BMS(battery management system) has been researched and developed to minimize shortening of battery life by keeping SOC(state of charge) and state of charge of lithium battery used in various industrial fields such as EV. However, the cell balancing operation based on the battery cell voltage can not follow the SOC change due to the internal resistance and the capacitor. Various battery equivalent models have been studied for estimation of battery SOC according to the internal resistance of the battery and capacitors. However, it is difficult to apply the same to all the batteries, and it tis difficult to estimate the battery state in the transient state. The existing battery electrical equivalent model study simulates charging and discharging dynamic characteristics of one kind of battery with error rate of 5~10% and it is not suitable to apply to actual battery having different electric characteristics. Therefore, this paper proposes a battery model coefficient correction algorithm that is suitable for real battery operating environments with different models and capacities, and can simulate dynamic characteristics with an error rate of less than 5%. To verify proposed battery model coefficient calibration method, a lithium battery of 3.7V rated voltage, 280 mAh, 1600 mAh capacity used, and a two stage RC tank model was used as an electrical equivalent model of a lithium battery. The battery charge/discharge test and model verification were performed using four C-rate of 0.25C, 0.5C, 0.75C, and 1C. The proposed battery model coefficient correction algorithm was applied to two battery models, The error rate of the discharge characteristics and the transient state characteristics is 2.13% at the maximum.

Development of GIS based Water Quality Simulation System for Han River and Kyeonggi Bay Area (한강과 경기만 지역 GIS 기반 통합수질모의 시스템 개발)

  • Lee, Chol-Young;Kim, Kye-Hyun
    • Journal of Korea Spatial Information System Society
    • /
    • v.10 no.4
    • /
    • pp.77-88
    • /
    • 2008
  • There has been growing demands to manage the water quality of west coastal region due to the large scale urbanization along the coastal zone, the possibility of application of TMDL(Total Maximum Daily Loadings) to Han river, and the natural disaster such as oil spill incident in Taean, Chungnam. However, no system has been developed for such purposes. In this background, the demand of GIS based effective water quality management has been increased to monitor water quality environment and propose best management alternatives for Han river and Kyeonggi bay. This study mainly focused on the development of integrated water quality management system for Han river bas in and its estuary are a connected to Kyeonggi bay to support integrated water quality management and its plan. Integration was made based on GIS by spatial linking between water quality attributes and location information. A GIS DB was built to estimate the amount of generated and discharged water pollutants according to TMDL technical guide and it included input data to use two different water quality models--W ASP7 for Han river and EFDC for coastal area--to forecast water quality and to suggest BMP(Best management Practices). The results of BOD, TN, and TP from WASP7 were used as the input to run EFDC. Based on the study results, some critical areas which have relatively higher pollutant loadings were identified, and it was also identified that the locations discharging water pollutant loadings to river and seasonal factor affected water quality. And the relationship of water quality between river and its estuary area was quantitatively verified. The results showed that GIS based integrated system could be used as a tool for estimating status-quo of water quality and proposing economically effective BMPs to mitigate water pollution. Further studies need to be made for improving system's capabilities such as adding decision making function as well as cost-benefit analysis, etc. Also, the concrete methodology for water quality management using the system need to be developed.

  • PDF

Analyses of Synchronous Fluorescence Spectra of Dissolved Organic Matter for Tracing Upstream Pollution Sources in Rivers (상류 오염원 추적을 위한 용존 유기물질 Synchronous 형광스펙트럼 분석 연구)

  • Hur, Jin;Kim, Mi-Kyoung;Park, Sung-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.317-324
    • /
    • 2007
  • Fluorescence measurements of dissolved organic matter(DOM) have the superior advantages over other analysis tools for applying to water quality management. A preliminary study was conducted to test the feasibility of applying synchronous fluorescence measurements for tracing and monitoring pollution sources in a small stream located in an upstream area of the Sooyoung watershed in Busan. The water quality of the small stream is affected by leachate from sawdust pile and discharge of untreated sewage. The sampling sites included an upstream site, two pipes discharging untreated sewage, leachate from sawdust, and a downstream site. Of the five field samples, the leachate was distinguished from the other samples by a high peak at a lower wavelength range and a blunt peak at 350nm, suggesting that synchronous fluorescence can be used as a discrimination tool for monitoring the pollution. The efficacy of various indices derived from the spectral features to discriminate the pollution source was tested for well-defined mixture of the sawdust leachate and the upstream stream by comparing (1)the difference between measured values and those predicted based on mass balance and the characteristics of the two samples and (2)the linear correlations between index values and mass ratios of the sample mixtures. Of various discrimination indices selected, fluorescence intensities at 276 nm$({\Delta}\lambda=30nm)$and 347 nm$({\Delta}\lambda=60nm)$ were suggested as promising potential discrimination indices for the sawdust pollution source. Despite the limited number of samples and the study area, this study illustrates the evaluation process that should be followed to develop rapid, low-cost discrimination indices to monitor pollution sources based on end member mixing analyses.