• 제목/요약/키워드: Discharges

Search Result 1,132, Processing Time 0.037 seconds

Numerical Analysis of Surface Discharge due to Particles Attached to the GIS spacer (GIS 스페이서에 파티클 부착시 연면방전과 전계해석)

  • Jang, D.G.;Lee, J.H.;Kwak, H.R.;Park, H.Y.;Kim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1788-1790
    • /
    • 2003
  • GIS is a typical power equipment with higher reliability. It is compact and safe because all the energized parts are enclosed by a sealed cylindrical tank which is filled with $SF_6$. Generally gas insulated power equipments like GIS are designed to have sufficient electrical strength to prevent partial discharges under normal operating condition. Despite of the careful processes in manufacturing, transporting and assembling, voids or particles can be created, resulting in partial discharges at electrically weak points. The key factors causing partial discharges in GIS are; particles, voids in solid insulation, protrusions, poor contact of metal components, etc. The particle can be attached on; spacers, electrodes, internal wall of the GIS tank. It also moves in GIS freely. Most of partial discharges are likely to occur when particles are attached to spacers. In this paper, the electrical characteristics of a surface discharge were investigated under various conditions by using simulation program of FEMLAB.

  • PDF

Effects of Soil Discharges on the Impulsive Ground Impedance of Ground Rod with Needles (침상 접지봉의 임펄스접지임피던스에 미치는 지중방전의 영향)

  • Yoo, Yang-Woo;Cho, Sung-Chul;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.98-105
    • /
    • 2014
  • Soil discharges near the ground rod play an important role to reduce the ground potential rise and the ground impedance and to help the fault current to spread into the earth. This paper presents the effects of soil discharges on the transient and conventional ground impedances when the lightning impulse voltage was applied to a ground rod with radial needles. The current-voltage (I-V)curves and transient ground impedance curves were calculated based on the measured current and potential traces. Soil discharge behaviors related to I-V curves and transient ground impedance curves were analyzed as a function of the magnitude of lightning impulse voltages. As a result, the soil discharges occurred near the ground electrode contribute to the reduction of conventional ground impedance and limits the ground potential rise effectively under lightning impulse voltages.

Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields (균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성)

  • Kim, Tae-Ki;Kim, Seung-Min;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.

Frequency Spectrum Analysis of Series Arc and Corona Discharges (직렬 아크 및 코로나 방전의 주파수 스펙트럼 분석)

  • Kil, Gyung-Suk;Jung, Kwang-Seok;Park, Dae-Won;Kim, Sun-Jae;Han, Ju-Seop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.7
    • /
    • pp.554-559
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of radiated electromagnetic pulses generated by series arc- and corona- discharges as a basic study to develop an on-line diagnostic technique for power facilities installed inside closed-switchboards. To simulate series arc and corona discharges, five types of electrode system which consists of needle and plane electrodes were arranged. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of an ultra log antenna and an EMI receiver. From the experimental results, the frequency spectrum exists in ranges from 30 MHz to 2 GHz for a series arc discharge and 30 MHz to 1.2 GHz depending on defects for a corona discharge. The peak frequency of the series arc- and corona- discharges were 100 MHz to 160 MHz and 40 MHz to 80 MHz, respectively.

The Characteristics of Tidal Residual Current in Youngil Bay (영일만의 조석잔차류 거동 특성)

  • Kim Jong-Kyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.4 no.1
    • /
    • pp.14-23
    • /
    • 2001
  • The characteristics of tidal circulation with Hyungsan River discharges in Youngil Bay by the numerical experiments is elucidated. For the simulation of tidal residual currents related to inflow by the river discharges in Youngil Bay located in the southeastern part of Korean Peninsula, the two-dimensional numerical experiment is peformed. The tidal elevation boundary conditions of the 4 main tidal harmonic constituents (M₂, S₂, K₁ and O₁) on the open boundary and river discharges at the river boundary are considered. The computed results obtained from numerical experiment showed good agreements with the field observation ones. The residual currents generally flow toward the inner bay through the western (Dalman-Gap) and central areas of the bay, and then the currents go toward the outer bay along the eastern shore (Changgi-Gap) of the bay with anti-clockwise circulation. Especially, in the numerical experiment without Hyungsan River discharges, these flow patterns are disappeared. Based on the results, it showed that the Hyungsan River discharges play the dominant role in the patterns of tidal residual currents. This flow pattern of tidal residual currents are important mechanism of water quality, material transport in Youngil Bay.

  • PDF

Considerations on the TF Anal,ysis using Partial Discharge Pulse Characteristics in Oil (유중 부분방전 펄스 특성을 이용한 TF 분석에 대한 고찰)

  • Kim, Jeong-Tae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.508-514
    • /
    • 2005
  • In this paper, it was investigated the characteristics of PD(partial discharge) pulse shapes in oil and the possibility of TF(Time-Frequency) analysis for the discrimination of air corona in on-site PD measurement of oil transformers. For the purpose, single and multiple discharges combined with oil discharges and air corona were generated and measured by use of artificial models through the HFPD pulse detector and the oscilloscope. PD pulse shapes were different according to the type of defects, especially including air corona- pulses. Also, through the TF analysis, data clusters could be classified each other in the TF Map, even in the case of multiple discharges. Therefore, it is known that TF analysis could be aprlied for the improvement of on-site PD measurement in oil transformers.

Statistical Characteristics of the Electromagnetic Pulses Radiated from Intracloud Discharges (운방전에 의한 뇌전자장 펄스의 특성)

  • Lee, B.H.;Lee, D.M.;Jeong, D.C.;Lee, S.C.;Ahn, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1882-1884
    • /
    • 2004
  • In this paper, the waveform parameters of electromagnetic pulses radiated from intracloud discharges were presented. The zero-crossing times and the full pulse widths of the large bipolar electromagnetic pulses due to intracloud discharges are gradually decreased as the stroke proceeds. Also, the electromagnetic pulses tend to be bipolar, with narrow and fast leader pulses superimposed on the initial half cycle. The mean numbers of leader pulses superimposed on the initial half cycle were 1.61${\pm}$0.74 and 1.75${\pm}$0.73 for the positive and negative polarities, respectively.

  • PDF

Periodic Lateralized Epileptiform Discharges Are lctal Phenomena, and Need an Antiepileptic Treatment (주기편측간질모양방전은 발작현상으로서 항경련제 치료가 필요하다)

  • Kim, Jae-Moon
    • Annals of Clinical Neurophysiology
    • /
    • v.13 no.1
    • /
    • pp.21-25
    • /
    • 2011
  • Periodic lateralized epileptiform discharges (PLEDs) had been debated whether it is ictal or non-ictal phenomenon. As most of PLEDs occur in patients with acute structural lesions, some epileptologists prefer PLEDS as a non-ictal phenomenon, rather an obscure epiphenomenon of etiological diseases. But, almost half of the patients with PLEDs do not have acute structural lesions in the brain and metabolic disorders or old CNS lesions may cause PLEDs and even more, no brain lesion was identified in some patients. There are many data supporting PLEDs as ictal phenomena. Occurrence of PLEDs usually accompanied by decreased mentality and is improved as PLEDs disappeared. Current SPECT study showed marked hyperperfusion in the lesion side of PLEDs, that is striking evidence of PLEDs as ictal phenomena. Also careful review of EEG with PLEDs revealed it is a dynamic process rather than a static state. Despite of these evidences, as PLEDs are an end-stage of animal status epilepticus models, it may be a transition of ictal to interictal state.

An Application of NN on Off-line PD Diagnosis to Stator Coil of Traction Motor (견인전동기용 고정자 코일의 Off-line 부분방전 진단을 위한 NN의 적용)

  • Park, Seong-Hee;Lim, Kee-Joe;Kang, Seong-Hwa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.8
    • /
    • pp.766-771
    • /
    • 2005
  • In this study, PD(partial discharge) signals which occur at stator coil of traction Motor are acquired these data are used for classifying the PD sources. NN(neural network) has recently applied to classify the PD pattern. The PD data are used for the learning process to classify PD sources. The PD data come from normal specimen and defective specimens such as internal void discharges, slot discharges and surface discharges. PD distribution parameters are calculated from a set of the data, which is used to realize diagnostic algorithm. NN which applies distribution parameters is useful to classify the PD patterns of defective sources generating in stator coil of traction motor.

Partial Discharge Measuring Technique in GIS using VHF Sensors (VHF 센서를 이용한 GIS에서 부분방전 측정 기법)

  • Kim, Jeong-Tae;Kim, Dong-Uk;Lee, Young-Jo;Koo, Ja-Yoon;Kim, Ji-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2063-2064
    • /
    • 2011
  • UHF PD sensor has some disadvantages in measuring void discharges due to their frequency characteristics lower than 300MHz. Therefore, in this study, the possibility of VHF sensor in measuring partial discharges(PD) in GIS was investigated using simulated experiments. As a result, by installing VHF sensors to the copper bus of the encloser in GIS, it is confirmed that partial discharges could be perfectly detected, which means that VHF PD measuring technique can be the alternative of UHF PD method.

  • PDF