• 제목/요약/키워드: Discharges

검색결과 1,132건 처리시간 0.029초

주기편측간질모양방전은 발작현상이 아니라 단지 급성 뇌손상을 반영하는 것이다 (Periodic Lateralized Epileptiform Discharges Are Not Ictal Phenomenon, and Just Reflect an Acute Brain Damage)

  • 이상암
    • Annals of Clinical Neurophysiology
    • /
    • 제13권1호
    • /
    • pp.26-30
    • /
    • 2011
  • Although the pathophysiologic mechanism is unknown, there has been long-running debate on whether periodic discharges such as periodic lateralized epileptiform discharges (PLEDs) and generalized periodic epileptiform discharges are an ictal or interictal EEG pattern. The goal of this review is to give evidence that such periodic discharges on EEG are not ictal phenomenon and just represent underlying acute brain damage. This review includes coma with epileptiform EEG pattern and its prognostic and therapeutic implications. Based on previous reports, rather than taking the view PLEDs represent either an underlying ictal process or an electrographic correlate of neuronal injury, it would be more reasonable that PLEDs are considered as a dynamic pathophysiological state in which unstable neurobiological processes create an ictal-interictal continuum.

Pulse-Sequence Analysis of Discharges in Air, Liquid and Solid Insulating Materials

  • Suwayno, Suwayno;Mizutani, Teruyoshi
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.528-533
    • /
    • 2006
  • Electrical discharges may occur in gas, liquid as well as solid insulating materials. This paper describes the investigation results on the discharges in air, silicone oil and low density polyethylene (LDPE) using needle plane electrode system under AC voltage of 50 Hz. The experimental results showed that for discharge in air (corona), discharge pulses were concentrated around the peak of applied voltage at negative half cycle. For silicone oil positive as well as negative discharges were observed which concentrated around the peak of applied voltage. The positive pulse number was smaller but the magnitude was higher than that of negative discharge. Discharges in void took place at wider range of phase of applied voltage. The unbalance in pulse number and magnitude similar to that of oil discharges were observed. For electrical treeing in LDPE, the discharges were spread before the zero cross of the applied voltage up to the peak at both positive and negative half cycles. The discharge pulse sequence analysis indicated that the PD occurrence in air, oil and void were strongly affected by the magnitude of applied voltage. However, for electrical treeing it was observed that the discharge occurrence was strongly affected by the time derivative of the applied voltage (dv/dt).

DC 부분방전 특성 비교 (comparison of Partial Discharge Characteristics of DC Voltage)

  • 김우빈;윤지섭;윤성호;남기진;김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1159-1159
    • /
    • 2015
  • This paper conducted the basic study on partial discharge analysis under the DC voltage. For the purpose, typical discharges such as void discharges, corona discharges and surface discharges with DC voltage were generated and measured. As a pattern analysis, various methods were adopted using the information including PD magnitudes and time interval.

  • PDF

홍수사상별 일평균유량 자료로부터의 참두홍수량 산정 (An Estimation of the Peak Flood Discharges Based on the Mean Daily Discharges during a Flood Event)

  • 원석연;윤용남
    • 물과 미래
    • /
    • 제26권2호
    • /
    • pp.59-65
    • /
    • 1993
  • 본 연구에서는 한강유역의 7개 수위관측소 지점에 기록된 총 198개의 홍수사상예 대한 일평균유량자료와 참두홍수량 자료를 Fuller방법 및 Sangal방법과 유사한 방법으로 상관시켜, 홍수기간별 일평규유량 자료로부터 그 기간동안의 참두홍수량을 산정할 수 있는 방법을 연구 분석하였다. Sangal 방법에 의한 참두홍수량의 산정결과는 실측치와 상당히 높은 상관성을 보였으며, 한강유역 전반에 걸쳐 제안된 지역화 기법은 유역내 수위관측소 지점의 홍수사상별 일평균유량으로부터 참두홍수량을 산정하는데 효과적으로 사용될 수 있을 것이다.

  • PDF

A New Type of Nonthermal Plasma Reactor

  • Geum, Sang-Taek;Moon, Jae-Duk;Jun, Sun-Gon
    • The Korean Journal of Ceramics
    • /
    • 제5권3호
    • /
    • pp.245-249
    • /
    • 1999
  • A new type of nonthermal plasma reactor utilizing ferroelectric pellets is proposed to generate nonthermal plasma efficiently, which is used for simultaneous control of various pollutant gases. Electric charges stored on ferroelctric pellets by corona discharge between a corona tip and a mesh electrode provide partial electrical discharges among ferroelectric pellets. These partial electrical discharges can enhance partial discharges around the surface of ferroelectric pellets. This method utilizes wide reacting area of ferroelectric pellets and partial discharge. Positive and negative dc voltage are applied to the corona tip to generate partial discharges, and corona currents are estimated to investigate charge storage on ferroelectric pellets as function of time and charge relaxation time constants of ferroelectric pellects. As a result, charge relaxationtime, dielectric constants of ferroelectric pellets, polarity of applied voltage and applied time influence partial discharges among ferroelectric pellect.

  • PDF

Near-Field Mixing Characteristics of Submerged Effluent Discharges into Masan Bay

  • Kang, See-Whan;You, Seung-Hyup;Na, Jung-Yul
    • Ocean and Polar Research
    • /
    • 제22권1호
    • /
    • pp.45-56
    • /
    • 2000
  • Hydrodynamic mixing characteristics of submerged effluent discharges into Masan Bay were investigated by both field observations and numerical model simulations. CORMIX model, a length-scale mixing model, was adopted to obtain the near-field dilution and wastefield characteristics of the effluent discharges into Masan Bay. Model predictions of the near-field dilution rates were in a good agreement with field observations in summer and winter seasons. Seasonal variations in the dilution rates showed that the highest dilution rate was obtained in winter while the lowest dilution rate was in summer. As the effluent discharges are increased with the treatment capacity expansion to be completed by 2011, the dilution rates are expected to be much reduced and the near-field stability of the wastefields will become unstable due to the increased effluent discharges.

  • PDF

침-평판 전극 구조에서 발생하는 기중 코로나 방전의 해석 기법 (Analysis Techniques of Corona Discharges in Air with Needle-Plane Electrode System)

  • 강성화;박영국;권순석;정수현;류부형;임기조
    • 한국안전학회지
    • /
    • 제11권4호
    • /
    • pp.49-53
    • /
    • 1996
  • Corona discharges in air insulated electric power systems cause power loss, produce interfering electromagnetic radiation, and can indicate incipient failure. An understanding of corona discharges in air gap is clearly Important. The Wavelet transformation is an extended method of fourier transformation. The fourier method is a powerful tool for signal analysis, but it can't include information for time. However the wavelet transformation analysis can include on the information of time and frequencies at the same time. In this paper we apply the wavelet transformation to the corona signals in needle-plane air gap for the purpose of analysis of developing aspects of corona discharges. We analyzed the developing aspects of corona discharges, namely, corona discharge current, repetition rates, width of Pulse distribution region, pulseless region and frequencies distribution of corona discharge pulses.

  • PDF

기중방전의 방전원별 특성분석 및 패턴분류 (Properties and Classification of Patterns of Air Discharges)

  • 박영국;이광우;장동욱;강성화;정광호;김완수;이용희;임기조
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권1호
    • /
    • pp.19-23
    • /
    • 2000
  • Partial discharges(PD)in air insulated electric power apparatus often lead to deterioration of solid insulation by electron bombardments and electrochemical reaction. The PD caused to reduce the life time of power apparatus and to increase power losses. Thus understanding and classification of PD patterns in air are very important to discern sources of PD. In this paper, PD in air by using statistical methods was investigated. We classified air discharges, corona, surface discharges and cavity discharges by Kohonen network. For classification of PD patterns, we used statistical operators and parameters such as skewness$(S^+,\; S^-),\; kurtosis(K^+, K^-),\; mean phase(AP^+, AP^-)$, cross-correlation factor(CC) and asymmetry derived from the mean pulse-height phase distribution$(H_{avg}(\phi))$, the max pulse-height phase distribution $(H_{qmax}(\phi))$, the pulse count phase distribution $(H_n(\phi))$ and the pulse height vs. Repetition rate $(H_q(n))$.

  • PDF

Ginsenoside Rg1 Reduced Spontaneous Epileptiform Discharges and Behavioral Seizure in the Zebrafish

  • Lee, Yun-Kyoung;Park, Eun-Jin;Lee, Sang-Hun;Kim, Yeon-Hwa;Lee, Chang-Joong
    • Journal of Ginseng Research
    • /
    • 제33권1호
    • /
    • pp.48-54
    • /
    • 2009
  • Epileptifrom discharges were induced in the telencephalon of the adult zebrafish via perfusion with pentylenetetrazole (PTZ), bicuculline methiodide, kainic acid-treated artificial cerebrospinal fluid (aCSF), and $Mg^{2+}$-free aCSF. Ginseng total saponin [GTS ($50{\mu}g/ml$)] was shown to attenuate the occurrence rate of epilpetiform discharges by 50-75%, compared to the control. Ginsenoside $Rg_1$ ($130{\mu}M$) reduced the epileptiform discharges in the isolated telencephalon and delayed the occurrence of behavioral seizures observed from the adult zebrafish placed in the PTZ (10 mM)-containing aquarium water. However, Re was not effective in the suppression of epileptiform discharges and behavioral seizures. These results indicate that $Rg_1$ may be useful in the control of epileptiform discharges and effective in controlling behavioral seizures, and that the zebrafish can be used as a model animal for the testing of potential anticonvulsant drugs.

수중 펄스코로나 방전에 의한 메틸오렌지 제거 특성 (Degradation of methyl orange by pulsed corona discharges in aqueous solution)

  • 이현돈;김종오;김형갑;정재우
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.69-76
    • /
    • 2012
  • A laboratory experiment on methyl orange degradation in pulsed corona discharges was carried out. Effects of operating parameters such as applied voltage, pH, conductivity and initial concentration on methyl orange degradation were investigated. The pulsed corona discharges decreased the pH of solution and increased conductivity, probably due to products generated from methyl orange degradation by corona discharges. The decrease of initial pH enhanced the methyl orange degradation. The methyl orange degradation was fastest in $100{\mu}S/cm$ conductivity solution, followed by 50 and $200{\mu}S/cm$, indicating that $100{\mu}S/cm$ is the most favorable in the aspect of radical generation among the experimented conditions. The methyl orange of initial concentration from 20 to 60mg/L was effectively degraded in pulsed corona discharges. The lower initial concentration of methyl orange, the faster degradation was observed.