• Title/Summary/Keyword: Discharge.

Search Result 13,065, Processing Time 0.039 seconds

Effects of Panel Temperature on the Discharge Characteristics of Micro Discharge Cells

  • Shim, Kyung-Ryeol;Park, Chung-Hoo;Lee, Ho-Jun
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.5
    • /
    • pp.215-219
    • /
    • 2004
  • The effects of ambient temperature on the discharge characteristics of Ne-Xe based micro discharge cells for ac-PDP (plasma display panel) have been studied. In ramp voltage driving, which is generally used as a reset method of PDP, two dissimilar modes of strong and weak discharge were found. As the interval between the former sustaining discharge and ramp voltage discharge becomes greater, the probability of a strong discharge increases. This suggests that a sufficient number of priming particles is necessary for initiating weak mode (Townsend discharge). It was discovered that under higher ambient temperatures, weak discharge occurs more frequently. The discharge time lag observed in square pulse driving of single cells becomes surprisingly smaller under higher ambient temperatures for the constant gas number density condition.

A Study on the Discharge AND Gate of Plasma Display Panels (플라즈마 디스플레이 패널의 방선 AND gate에 간한 연구)

  • 손현성;채승엽;염정덕
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.39-46
    • /
    • 2001
  • The plasma display panel with the electrode structure of new discharge AND gate was developed and the driving system for experiment was developed. And discharge AND gate operation was verified. Discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 20V. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because this method uses the DC discharge, the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the imput discharge and the output discharge of AND gate are separate, the display discharge can be prevented from passing AND gate. Therefore, it is possible to apply to the large screen plasma display. And the decrease of contrast ratio does not occur because the scanning electrical discharge does not influence the picture quality.

  • PDF

Optimization on the Characteristics of DC Discharge Cell in the AND Gate PDPs (ADN Gate PDP의 DC 방전셀 방전특성 최적화)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.34-39
    • /
    • 2004
  • This research investigated the influence on the 4 cell of DC discharge on the side of the discharge characteristic. This DC discharge cells are that composes AND gate of AND gate PDP newly proposed. As for the discharge starting voltage of this discharge cell of 4 pieces, it has been understood that there is deeply a relation up to the space charge generated from the discharge of adjoining discharge cell through the experiment. The discharge voltages which had become each discharge cell optimizations from the experiment result were decided. Moreover, the width of the margin of two AND input voltages is wide and the AND function occurs clearly. However, it has been qualitatively understood that it is difficult enough to obtain the operation margin of the DC priming discharge used to address discharge of PDP.

The Simulated study of different partial discharge sources in GIS (모의된 GIS에서 발생하는 부분방전에 관한 연구)

  • Kang, Dae-Yong;Wu, Guangning;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1737-1739
    • /
    • 1998
  • The paper presents experimental results of Partial Discharge(PD) in Gas Insulated Switchgear(GIS), obtained using a computer-aided PD measurement system. Different discharge sources are simulated and identified. These included internal, interface, surface and protrusion. For internal discharge, it showed symmetrical discharge type between positive and negative cycle. Interface discharge showed smaller number and higher peak than internal discharge but symmetrical discharge as well. For surface discharge, it showed small number and high peak in positive half cycle but large number and low peak in negative half cycle. For protrusion discharge, small number and high peak of discharge were shown only in negative half cycle.

  • PDF

Modification of Discharge Mechanism of Binder Harvesters (바인더수확기(收穫期)의 방출구조(放出構造) 개선(改善)에 관한 연구(硏究))

  • Park, Keum Joo;Chung, Chang Joo;Ryu, Kwan Hee
    • Journal of Biosystems Engineering
    • /
    • v.8 no.2
    • /
    • pp.26-38
    • /
    • 1983
  • Binder harvesters introduced to Korea were originally designed to be used for Japonica varieties which are highly resistant to shattering. In order to improve the performance of the binder to Indica varieties which are easily shattered and have shorter stem, mechanical modifications of the binder are inevitable. Shattering losses of the binder can be classified into two major parts; one incurred before and one after binding operations. The latter has been evaluated as great as the former. Previous studies indicated that the high discharge losses resulted from a great impact force of the discharge arm on the rice bundle during the discharge process. This study was intended to theoretically analyze the discharge mechanism of four-bar linkage. For this purpose, two commercially available binder harvesters having a four-bar linkage as a discharge mechanism were analyzed. Using the results from the motion analysis and the other structural constraints of the machines, they were modified and experimentally compared with the machines without modification to see whether any decrease in grain losses was obtained. The results obtained in this study are summarized as follows: 1. The path, velocity and acceleration of discharge arm were computer analyzed by vector analysis. Using results of the analysis and intrinsic constraints of the binder, discharge mechanism was modified to reduce the impact force on bundle by discharge arm in the range where the discharge performance was not deteriorated. This modification of the discharge mechanism could be done with an aid of four-bar linkage synthesis technique. As a result, average velocity and acceleration of the discharge arm during the discharge process were reduced respectively by 19 percent and 33 percent for binder A, and 17 percent and 35 percent for binder B. 2. Through the modification of the discharge mechanism, discharge losses of binder A were reduced by 42-56 percent for Milyang 23, Poongsan and Hangang chal, and discharge losses of binder B were reduced by 13-20 percent for Milyang 23 and Poongsan. 3. Discharge losses were decreased as the bundle size became larger and the size effect on the decrease rate appeared more significant in the binders with modifications than in those without modifications.

  • PDF

The Effects of Nursing Information on knowledge, physical symptoms, state anxiety and daily activity levels of patients recovering from open heart surgery (퇴원시 간호정보 제공이 개심술 환자의 지식, 신체증상, 상태불안 및 일상활동에 미치는 효과에 관한 연구)

  • 김금순;유경희
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.3
    • /
    • pp.257-267
    • /
    • 1991
  • This study investigated the effects of nursing in formation given verbally and a booklet on the knowledge, Physical symptoms, anxiety and daily activities of patients recovering from open heart surgery from just before discharge to six weeks after discharge. The convenience sample was of patients who had undergone open heart surgery in Seoul National University Hospital. The first 25 patients who agreed to participate in the study became the control group. They did not receive the intentional information but the usual nursing care. The next 28 patients became the experimental group who received a booklet about their post-discharge care which was discussed with them by the researcher before discharge. This study used a non equivalent control group non - synchronized quasiexperimental design. The tools included a 30 item knowledge scale, a 9 item physical symptom scale, Spielberger's state anxiety scale, and a 28 item daily activity scale. The instruments were applied before discharge and at two and six weeks after discharge. For data analysis, frequency, t-test, Pearson's Correlational Coefficient and Cronbach's $\alpha$ were used. The results were as follows : 1. Information given through the booklet was effective in increasing the knowledge of patients recovering from open heart surgery. The experimental group's knowledge was higher at 2 weeks after discharge than prior to discharge (P<0.05). 2. There was no significant difference in physical symptoms between the two groups at two and six weeks after discharge. 3. Information given through the booklet was effective in decreasing the State Anxiety two weeks after discharge (P<0.001) but at six weeks after discharge, there was no significant difference in anxiety between the control and the experimental groups. 4. There was no significant difference in daily activity between the two groups at two and six weeks after discharge. 5. There was a negative correlation between knowledge at discharge and at 2 weeks and anxiety at 2 weeks after discharge. There was a positive correlation between knowledge at discharge and daily activity at 2 weeks after discharge. There was a negative correlation between knowledge at 2 weeks and Physical symptom at 6 weeks after discharge.

  • PDF

Glow Discharge as Detector for Gas Chromatography (글로우방전을 이용한 가스크로마토그라프 검출기의 개발)

  • 김효진;박일영;장성기;김박광;박만기
    • YAKHAK HOEJI
    • /
    • v.37 no.1
    • /
    • pp.76-83
    • /
    • 1993
  • The changes in discharge current, emission and/or oscillation frequency of the electric oscillation of a glow discharge are the potential sensitive measure of the concentration of an impurity in the argon plasma supporting gas. A single jet enhanced glow discharge has been interfaced with the gas chromatograph via 1/8" O.D. tube with a heating pad to study the changes in discharge current. To investigate the optimum operating conditions of the glow discharge system as detector for gas chromatography, pressure, gas flow rate, discharge current, distance between the anode and the cathode have been studied.

  • PDF

Effect of Dielectric Materials on the Silent Discharge Characteristics for Ozone Generation (오존발생을 위한 무성방전특성에 미치는 유전체의 영향)

  • 박명하;곽동주
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.628-630
    • /
    • 2000
  • Since the concept for the ozone generation using a nonequilibrium electric discharge techniques had been proposed by Siemens, some experimental and theoretical studies on the ozone generation by streamer corona discharge, surface discharge and silent discharge have been performed. In this paper some results on the discharge characteristics of the silent discharge gap with various dielectric materials were reported. Dielectric materials used in this study were pyrex glass, quartz and glass beefs with diameter of 1 mm.

  • PDF

A Study on the Characteristics of Floating Discharge in the AND Gate PDP (AND Gate PDP의 Floating 방전특성에 관한 연구)

  • 염정덕
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.22-27
    • /
    • 2004
  • The gas discharge AND gate which have been newly proposed is applied to three electrode surface discharge AC PDP. The address discharge characteristics by the DC-AC floating discharge by which Y electrode is made floating electrode is analyzed The address discharge can be begun by using the floating discharge from the experiment result Moreover, the display discharge can be sustained. The DC priming discharge that the floating discharge is matched to timing is generated in a supplementary electrode. As a result, space charge is supplied enough to the space of the floating discharge and the data voltage is lowered up to l00(V). Driving method to use this DC-AC floating discharge is able to obtain the address operation margin of l00(V).

An Experimental Study on the Implementation and Stabilization of Atmospheric Pressure Glow Discharge (대기압 글로우 방전의 구현 및 안정화에 대한 실험적 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.42-46
    • /
    • 2008
  • Ionizers are essential in various areas of manufacturing industries to protect electrostatic hazards and to reduce inferior products. For ion sources used in the charge neutralizers, there are corona discharge, soft X-ray, ultraviolet and glow discharge. Glow discharge has lots of attractive properties, such as lower discharge sustaining voltage, no generation of ozone, and so on. In this paper, we did an experimental study to trace the mechanism and stabilization of atmospheric pressure glow discharge using the several size and shape of electrodes. As an experimental result, to sustain conditions of atmospheric pressure glow discharge is that discharge voltage is 360V, discharge current is 12mA, apply frequency is 1kHz between electrodes when positive electrode is molybdenum(Mo) and negative electrode is copper(Cu). We confirmed that the mechanism and stabilization of atmospheric glow discharge is deeply concerned with the shape and material of electrode for discharge. Especially, glow discharge in atmospheric pressure was well generated and sustained according with the physical properties used electrode materials, example melting point, thermal conductivity, and etc.