• Title/Summary/Keyword: Discharge time

검색결과 2,623건 처리시간 1.136초

Ionizing Characteristic of Glow Discharge by Controlled Air Flow Rate (공기유량에 따른 글로우 방전의 제전 특성)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • 제23권5호
    • /
    • pp.49-53
    • /
    • 2008
  • Glow discharge has lots of attractive properties, such as lower discharge sustaining voltage, no generation of ozone, and so on. And more, ionizer was developed recently using an atmospheric pressure glow discharge. On the other hand, ionizer needs a compressed or blown air to transport ion for charged objects. This air is very useful in explosive hazardous area to prevent the explosion of flammable gas and/or vapor by ignition sources, e.g. electrical spark. In this paper, we investigated the ionizing characteristic of atmospheric pressure glow discharge by controlled air flow rate from 5 liters to 60 liters a minute, and compared with decay time between the corona discharge and glow discharge as a function of some direction and distance from discharge ion source. We confirmed that an air flow rate needs 25 liters a minute to sustain the most suitable atmospheric pressure glow discharge and to increase an ionizing efficiency.

Time Delay Characteristics of Radiated Electromagnetic Wave with Partial Discharge (부분방전시 방사전자파의 시간지연특성)

  • Kim, Hae-Joon;Park, Kwang-Seo;Lee, Hyun-Dong;Kim, Ki-Chai;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1774-1776
    • /
    • 2001
  • The most of faults in gas insulation of power facilities are caused by partial discharge. Therefore we simulated partial discharge and measured the radiated electromagnetic wave emitted from partial discharge in the $SF_6$ gas by biconical antenna. This paper describes time delay characteristics of radiated electromagnetic waves with distance between antenna and discharge source.

  • PDF

Influence on Metal Removal Rate by Material and Size Difference of the Electrode (전극의 재료와 크기가 방전가공량에 미치는 영향)

  • 김희중
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.809-815
    • /
    • 1998
  • This study has been performed to investigate MRR(metal removal rate) surface roughness with various pulse-on duration using the copper and graphite electrode according to the electrode size on the heat treated STD 11 which is extensively used for metallic molding steel in the EDM. The results obtained are as follow ;a)MRR increases a lot when pulse-on duration is 100 $\mu{s}$ or less but MRR has little difference with pulse-on duration of 100 $\mu{s}$ or more b) According to the increase of Pulse-on duration the large the electrode size the more MRR c) Safe discharge is needed to make maximum of MRR and the metallic organization must be complicated for discharge induction. d) Actual machining time is longer than theoretical machining time at the short pulse-on duration because of skin effect of current. e) Graphite electrode needs the larger electric discharge energy than copper electrode to remove remained chips completely.

  • PDF

Study on the Partial Discharge Characteristics in Polyethylene Using Ultrasonic Sensors (초음파 센서를 이용한 폴리에틸렌의 부분방전특성연구)

  • 이정원;서광석;박치영;곽회로;송일근
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.283-286
    • /
    • 1996
  • A signal generated by partial discharge in low density Polyethylene (LDPE) and cross- linked polyethylene (XLPE) has been detected by ultrasonic sensors. The observed signal is analysed with the quantity of partial discharge, number of peaks, and energy ($\Sigma$y$^2$). It was found that signals between LDPE and XLPE are quite different and that the signal of XLPE has very long duration time and rising time, and that the quantity of partial discharge of XLPE is saturated. It was also found that tree retardant XLPE (TR-XLPE) has lower quantity of partial discharge, number of peaks, and energy than naturalal XLPE.

  • PDF

Experimental Analysis on the Desulfurizarion and Denitrification Efficiencies in Pulsed Corona Discharge Process (펄스 코로나 방전 공정에서 탈질, 탈황 효율의 실험적 분석)

  • Kim, Sung-Min;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • 제23권A호
    • /
    • pp.181-186
    • /
    • 2003
  • In this study, we analyzed $NO_x$ and $SO_x$ removal efficiencies by a pulsed corona discharge process and investigated the effect of several process variables. The removal efficiencies of NO and $SO_2$ were measured changing the process variables of initial concentrations of NO, $H_2O$, and $NH_3$, $SO_2$, applied voltage, pulse frequency and residence time. As the applied voltage or the frequency of applied voltage or the residence time increases, the NO and $SO_2$ removal efficiencies increase. The NO and $SO_2$ removal efficiencies also increase by the addition of $O_2$ or $H_2O$, or by using the large diameter of the discharge electrode. The experimental results can be used as a basis to design the pulsed corona discharge process to remove $NO_x$, $SO_x$ and VOCs.

  • PDF

Identification of Partial Discharge Defect Detection in Cast-Resin Power Transformers Using Back-Propagation Algorithm

  • Sung-Wook Kim
    • Journal of information and communication convergence engineering
    • /
    • 제22권3호
    • /
    • pp.231-236
    • /
    • 2024
  • This paper presents a method used to identify partial discharge defects in cast-resin power transformers using a back-propagation algorithm. The Rogowski-type partial discharge (PD) sensor was designed with a planar and thin structure based on a printed circuit board to detect PD signals. PD electrode systems, such as metal protrusions, particle-on-insulators, delamination, and void defects, were fabricated to simulate the PD defects that occur in service. PD characteristics, such as rising time, falling time, pulse width, skewness, and kurtosis without phase-resolved partial discharge patterns, were extracted to intuitively analyze each PD pulse according to the type of PD defect. A backpropagation algorithm was designed to identify PD defects using a virtual instrument (VI) based on the LabVIEW program. The results show that the accuracy rate of back-propagation (BP) algorithm reaches over 92.75% in identifying four types of PD defects.

Estimation of Maintenance Flow for Suitable Utilization of Fishway (어도의 적절한 이용을 위한 유지유량 평가)

  • Kim, Seok-gyu;Kim, Chul;Kim, Seonghwan;Ko, Kwangyong
    • Journal of Korean Society on Water Environment
    • /
    • 제25권2호
    • /
    • pp.281-287
    • /
    • 2009
  • Achieved monitoring regularly about fishway that is a intake dam belongings to Kyeongchon for 5 years. Result that achieve monitoring, discovered pressing issue of opening and closing degree of discharge control part in fishway. In this research, analyze discharge relation with fishway and intake sluice and presented operation plan of opening and closing of discharge control part. Investigated necessity intake discharge and benefited area to analyze relation of discharge that is flowed in fishway and discharge escaping by intake sluice. When opened discharge control part step by step gradually, analyzed discharge. Compared with survey discharge making ration curve of fishway and intake sluice using orifice and submerged weir formula. Because operation of intake dam is necessary intake discharge and upriver inflow discharge by time, operation uses by survey discharge and calculated opening discharge of fishway by opening discharge of intake sluice via monthly inflow discharge. To sum up, calculated floodgate opening height of fishway by water level to present maintenance standard of intake dam.

A Study of the Method for External Noise Shielding using the GIS UHF Sensor Module Applied to the Partial Discharge Signal Sensitivity and Method of Frequency Transforming in the Internal GIS (GIS내부의 부분방전신호 감도개선 및 주파수변환기법에 의한 GIS UHF Sensor 모듈의 외부노이즈차폐기법에 관한 연구)

  • Lee, Seung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제59권4호
    • /
    • pp.728-732
    • /
    • 2010
  • GIS(Gas insulated switching gear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. Recently, because equipment of GIS was occurring problem of confidence used for a long time, partial discharge on-line diagnosis systems have been importantly recognized. Partial discharge (PD) detection is an effective means for monitoring and evaluation of dielectric condition of gas insulated system (GIS). The ultra-high-frequency (UHF) PD detection technique can detect and locate the PD sources inside GIS by detecting electromagnetic wave emitted from PD source. Therefore, real-time diagnostic system using UHF detection method has been developed for this application is being expanded gradually. However, the signal of partial discharge occurring in SF6 gas is very weak and susceptible to external noises which mainly consist of PD in air. Thus, it is important to distinguish the PD in SF6 gas more sensitively from the external noises. Unfortunately, these external noise signals and the partial discharge signals have very similar characteristics. Therefore, to solve this problem, we need the signal processing method for distinguish partial discharge signals with external noise signals for improvement of SNR(signal to noise ratio) and sensitivity. In this paper, we proposed internal signal processing method for removing external noise signals with built-in pre.amplifier and frequency conversion circuit.

Classification Technique of Kaolin Contaminants Degree for Polymer Insulator using Electromagnetic Wave (방사전자파를 이용한 고분자애자의 오손량 분류기법)

  • Park Jae-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제19권2호
    • /
    • pp.162-168
    • /
    • 2006
  • Recently, diagnosis techniques have been investigated to detect a Partial Discharge associated with a dielectric material defect in a high voltage electrical apparatus, However, the properties of detection technique of Partial Discharge aren't completely understood because the physical process of Partial Discharge. Therefore, this paper analyzes the process on surface discharge of polymer insulator using wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time~frequency domain. As it is important to develop a non-contact method for detecting the kaolin contamination degree, this research analyzes the electromagnetic waves emitted from Partial Discharge using wavelet transform. This result experimentally shows the process of Partial Discharge as a two-dimensional distribution in the time-frequency domain. Feature extraction parameter namely, maximum and average of wavelet coefficients values, wavelet coefficients value at the point of $95\%$ in a histogram and number of maximum wavelet coefficient have used electromagnetic wave signals as input signals in the preprocessing process of neural networks in order to identify kaolin contamination rates. As result, root sum square error was produced by the test with a learning of neural networks obtained 0.00828.

Discharge Capacity of Prefabricated Vertical Drain Confined In-Clay Under Long-Term Conditions (연직배수재 타설 후 장기간 경과된 지반의 통수성능)

  • Jeong, Sang-Guk
    • Journal of the Korean Geosynthetics Society
    • /
    • 제17권4호
    • /
    • pp.239-249
    • /
    • 2018
  • Typically, soft clay improvement is carried out using installation of PVD and surcharge method. According to circumstances, installed PVD has left for a long time due to the change in construction schedule. Therefore, for simulation of this kind of condition, discharge capacity tests were carried out under a series of temperature condition (30, 35, $40^{\circ}C$). The results indicated that under water confinement, the discharge capacities significantly reduced with elapsed time. And, the empirical equation by Miura and Chai (2000) was used for estimating the long-term in-clay discharge capacity. Based on the test results, it is recommended that in term of long-term discharge capacity, Miura and Chai's equation and reliability evaluation using discharge capacity tests under a series of temperature condition may be used.