Discharge Capacity of Prefabricated Vertical Drain Confined In-Clay Under Long-Term Conditions  

Jeong, Sang-Guk (Department of Civil Engineering, Songwon University)
Publication Information
Journal of the Korean Geosynthetics Society / v.17, no.4, 2018 , pp. 239-249 More about this Journal
Abstract
Typically, soft clay improvement is carried out using installation of PVD and surcharge method. According to circumstances, installed PVD has left for a long time due to the change in construction schedule. Therefore, for simulation of this kind of condition, discharge capacity tests were carried out under a series of temperature condition (30, 35, $40^{\circ}C$). The results indicated that under water confinement, the discharge capacities significantly reduced with elapsed time. And, the empirical equation by Miura and Chai (2000) was used for estimating the long-term in-clay discharge capacity. Based on the test results, it is recommended that in term of long-term discharge capacity, Miura and Chai's equation and reliability evaluation using discharge capacity tests under a series of temperature condition may be used.
Keywords
Long-term in-clay discharge capacity; Temperature condition; PVD;
Citations & Related Records
연도 인용수 순위
  • Reference
1 ASTM D4716 (2014), "Standard test method for determining the (in-plane) flow rate per unit width and hydraulic transmissivity of a geosynthetic using a constand head".
2 Arrehenius, S. A. (1889), "Uber die Dissociationswarme und den Einfluss der Temperatur auf den Dissociationsgrad der Elektrolyte", Zeitschrift fur Physikalische Chemie, Vol 4U, Issue 1, pp.96-116.
3 Chai, J. C. and Miura. N. (1999), "Investigation of factors affecting vertical drain behavior", J. of Geotech. and Geoenvir. Engrg., ASCE, Vol.125, No.3, pp.216-226.   DOI
4 Korea Reliability Certification Center (2016), "Prefabricated vertical drain board for soft ground improvement", RSKORAS-FITI-021.
5 KS K 0940 (2008), "Test method for discharge capacity of plastic drain board".
6 KS K ISO 18325 (2017), "Geosynthetics-Test method for the determination of water discharge capacity for prefabriacated vertical drains".
7 Miura. N., Chai, J. C. and Toyota, K. (1998), "Investigation on some factors affecting discharge capacity of prefabricated vertical drain", Proceedings of 6th International Conference on Geosynthetics, Atlanta, pp.845-850.
8 Miura. N. and Chai, J. C. (2000), "Discharge capacity of prefabricated vertical drain confined in-clay", Geosynthetics Journal, Japan Chapter of International Geosynthetics Society, Vol.15.
9 Waloddi Weibull (1951), "A Statistical Distribution Function of Wide Applicability", Journal of Applied Mechanics.