• Title/Summary/Keyword: Discharge time

Search Result 2,603, Processing Time 0.032 seconds

Normalization Diagnosis of Aging Process on Partial Discharge Signals of CV Cable (CV케이블의 부분방전 신호를 통한 열화과정의 정량적 진단)

  • 소순열;임장섭;김진사;이준웅;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.451-455
    • /
    • 1997
  • The partial discharge has been blown as the chief breakdown of power equipments. The analysis and the recognition is much difficult because the partial discharge signal is very small and has complex aging pattern. Recently, insulation aging diagnosis based on pattern of phase(Ф), partial discharge magnitude(q), number(n) has been very important. Owing to depreciate the reappearance of aging progress at the electrical tree pattern and to be difficult to analyze visually, the study on partial discharge pattern is suggested to normalizing analysis method of partial discharge signals. This parer is purposed on prediction of life-time measurement of cv-cable, on decision of risk degree with normalization and real-time measurement of partial discharge signals for aging diagnosis of cv-cable. As normalizing the aging signals of electrical tree in cv-cable, it is able to confirm risk degree of insulation material with the distribution of Ф-q-n and recognize the process of aging pattern using neural network.

  • PDF

Study on Characteristics of Write Discharge with Single Sustain Waveform in AC Plasma Display Panel (교류형 플라즈마 디스플레이에서 단일 유지 파형을 가지는 기입 방전의 특성의 연구 )

  • Byung-Gwon Cho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.1
    • /
    • pp.56-61
    • /
    • 2023
  • The characteristics of write discharge were investigated when the conventional driving method with the unipolar sustain voltages, and the single sustain driving method applying the bipolar sustain voltage were applied in an AC plasma display. In the case of having a single sustain waveform, the strength of the write discharge is weakened compared to the conventional driving method during the address period, because the wall charge inside the panel is more dissipated by the lower scanning voltage. In the driving method with a single sustain waveform, the bias voltage of the other electrodes was changed to improve the write discharge characteristics. As a result, the intensity of the discharge was enhanced by 32% and the delay time was shortened by 60 ㎲.

Current Limiting and Discharge Characteristics of High Tc Superconductive Fuse (고온 초전도 퓨즈의 한류 및 방전 특성)

  • Choi, Hyo-Sang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.673-677
    • /
    • 2004
  • We present the basic properties of a superconductive fuse (SF) based on YBCO/Au films. The SF consists of YBCO stripes covered with Au layers for current shunt. The fault current was limited to a designed value in less than 0.4 msec by resistance development in YBCO/Au upon quenching. This enabled the SF to transfer small fault power and the suppressed current was sustained for more than 0.5 msec while Au layer melting and arcing. The arcing time was less than 2.5 msec, that is short enough to do self-interruption. Under the source voltage of 100 $V_{rms}$, the longer the duration time of fault current was, the shorter its discharge time was. The duration time of fault current and its discharge time were reduced by increased voltages in the range of 200 - 300 $V_{rms}$. We thought that this was because the quench propagation was limited by local melting generated with higher voltage.age.

A Study on the Improvement of the Low Temperature Address Discharge Time Lag of High-Xe Content AC PDP (AC PDP의 저온에서 어드레스 방전 지연 시간 개선에 관한 연구)

  • Kim, Ji-Yong;Kim, Sun;Lee, Seok-Hyun;Lee, Jeong-Hae;Kim, Jun-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2156-2159
    • /
    • 2005
  • ADS(Address Display Period Separation) driving method has been considered to be the most appropriate driving technique for AC PDP. ADS driving method is composed of reset, address, sustain and erase period. Therefore, a long time should be allocated to an address period, which results in a reduction of brightness. To realize a high luminance and high picture quality, it is necessary to high speed addressing. However, address discharge time lag increases as the temperature decreases, which can cause the misfiring and low picture quality In this paper, the electric field effect and priming particle effect are investigated in order to reduce the address discharge time lag at low temperature. Address discharge time lag was reduced effectively when the priming particles are provided.

  • PDF

Surface Deterioration Phenomena in Polyethylene under Corona Discharge (Corona 방전에 의한 Polyethylene의 표면열화현상)

  • 성영권;송진수;민남기
    • 전기의세계
    • /
    • v.24 no.5
    • /
    • pp.82-90
    • /
    • 1975
  • This study investigated the deterioration phenomena of the Polyethylene surface contaminated with organic(Saccharose) or inorganic(NaCl) matters through electrical and optical experiments. And also these experimental results relatively well coincided with which was treated by theoretical process. On the electrical experiment, relation between electric field intensity in corona discharge and time reached to the breakdown, and relation between total amount of charges discharged and increment of applied voltage were investigated. On the optical experiment, discharge time dependence of surface deterioration rate and process of surface deterioration in the X-ray diffraction pattern were investigated. It was concluded that chemical effects by the corona discharge deteriorated insulation characteristics of Polyethylene surface.

  • PDF

Discharge Education and Educational Demands After Hospital Discharge for Mothers of Pediatric Cancer Patients (암 환아 어머니가 받은 퇴원시 교육정도와 퇴원후 교육요구도)

  • Kim, Young-Hae;Jeung, Eun-Ok;Cho, Young-Ran;Yang, Young-Ok
    • Child Health Nursing Research
    • /
    • v.12 no.2
    • /
    • pp.268-276
    • /
    • 2006
  • Purpose: this study is attempted to provide basic data on development of systematic discharge educational programs for discharging cancer patients. Method: The subjects of this study were 132 mothers whose children were diagnosed with cancer and being treated at 3 university hospitals in Busan. The data were collected from December 1 to February 28, 2005, and were analyzed Using SPSS WIN 10.0. Result: The degree of education at the time of discharge from hospital was statistically significantly lower than that of educational demand after the discharge. Such demand significantly varied in accordance with the length of period passed after the discharge. Mother’s educational demand was significantly different in accordance with generation characteristics of her child with cancer, especially the first period of hospitalization and change in weight Conclusions: mothers of children with cancer were higher in educational demand after the child’s discharge from hospital than in education provided at the time of the discharge. Such demand was different in accordance with the length of period passed after the child's discharge from hospital.

  • PDF

The Partial Discharge Properties of Oxidized Polyethylene (산화된풀리에틸렌의 부분방전 특성)

  • 이현수;한상옥
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.7
    • /
    • pp.802-808
    • /
    • 1992
  • To investigate degradation procedure and life time of the oxidized PE and the unoxidized PE, alternative voltage is applied to the CIGRE Method-II (CM-II) electrode system, which is loaded artificial void, and measures the distribution of partial discharging generation. From the results, the samples etched by oxidation had wide degradation area of dielectric strength. Furthermore, discharge starting voltage was shifted to low voltage, the discharge generation frequency was high and consequently, the quantity of mean charge becomes small. Also, life time of the oxdized sample is shortened according as the oxidation time is longer.

  • PDF

Investigation of the Driving Frequency Effect on the RF-Driven Atmospheric Pressure Micro Dielectric Barrier Discharges

  • Bae, Hyowon;Lee, Jung Yeol;Lee, Hae June
    • Applied Science and Convergence Technology
    • /
    • v.26 no.4
    • /
    • pp.74-78
    • /
    • 2017
  • The discharge characteristics of the radio frequency (RF) surface dielectric barrier discharge have been simulated for the investigation of the ratio of the ion transit time to the RF period. From one-dimensional particle-in-cell (PIC) simulation for a planar dielectric barrier discharge (DBD), it was observed that the high-frequency driving voltage confines the ions in the plasma because of a shorter RF period than the ion transit time. For two-dimensional surface dielectric barrier discharges, a fluid simulation is performed to investigate the characteristics of RF discharges from 1 MHz to 40 MHz. The ratio of the peak density to the average density decreases with the increasing frequency, and the spatiotemporal discharge patterns change abruptly with the change in the ratio of ion transit time to the RF period.

Analysis on the Discharge Capacity of Vertical Drains Installed in the Field (현장에 타설된 연직배수재의 통수능력 분석)

  • 박영목;진규남;정하익;정길수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.512-519
    • /
    • 2000
  • The discharge capacity of vertical drains installed in the field is reduced with time elapsed after installation due to deformation of drains and clogging effect. Discharge capacity of two types of vertical drains was analysed about three years after installation in the subsoil. Discharge capacity of two types of vertical drains were measured by small, middle, and large scale test apparatus. The results indicate that the discharge capacity of vertical drains after three years operation dramatically decreased compare to the initial discharge capacity.

  • PDF

Machining Characteristics According to the Thickness Change When Wire-cut Electrical Discharge Machining of Tungsten Carbide (초경합금재 와이어컷 방전가공시 두께변화에 따른 가공 특성)

  • 이재명;김원일;이윤경;왕덕현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.820-823
    • /
    • 2000
  • The characteristics of wire deflection, surface roughness and roundness were observed on changing discharge time for electrical discharge machining(EDM) of tungsten carbide in various conditions of thickness. The wire deflection was decreased as increasing discharge time and wire tension, the gap of deflection was decreased after thickness 60mm and discharge time of 6$\mu\textrm{s}$ due to the changing from fundamental mode to vibration mode. The deflection is the smallest at the water specific resistivity of 7.5 kΩ ㆍcm. The deflection is found to be decreased as increasing dwell time, and the result is due to the vibration of the pressure and the amount of the dielectric. The component of copper(Cu) and zinc(Zn), which is the main material of wire electrode, was observed for rough wire-cutting EDM of STD-11. This phenomena is found to be decreased as the number of EDM is increased. But it will be improved by changing the material and the shape of wire. The roundness of middle is found to be worse than that of upper and it is increased as the thickness of material is increased.

  • PDF