• Title/Summary/Keyword: Discharge ratio

Search Result 1,070, Processing Time 0.027 seconds

Efficacy of mid-upper arm circumference in identification, follow-up and discharge of malnourished children during nutrition rehabilitation

  • Mogendi, Joseph Birundu;De Steur, Hans;Gellynck, Xavier;Saeed, Hibbah Araba;Makokha, Anselimo
    • Nutrition Research and Practice
    • /
    • v.9 no.3
    • /
    • pp.268-277
    • /
    • 2015
  • BACKGROUND/OBJECTIVES: Although it is crucial to identify those children likely to be treated in an appropriate nutrition rehabilitation programme and discharge them at the appropriate time, there is no golden standard for such identification. The current study examined the appropriateness of using Mid-Upper Arm Circumference for the identification, follow-up and discharge of malnourished children. We also assessed its discrepancy with the Weight-for-Height based diagnosis, the rate of recovery, and the discharge criteria of the children during nutrition rehabilitation. SUBJECTS/METHODS: The study present findings from 156 children (aged 6-59 months) attending a supplementary feeding programme at Makadara and Jericho Health Centres, Eastern District of Nairobi, Kenya. Records of age, weight, height and mid-upper arm circumference were selected at three stages of nutrition rehabilitation: admission, follow-up and discharge. The values obtained were then used to calculate z-scores as defined by WHO Anthro while estimating different diagnostic indices. RESULTS: Mid-upper arm circumference single cut-off (< 12.5 cm) was found to exhibit high values of sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio at both admission and discharge. Besides, children recorded higher rate of recovery at 86 days, an average increment of 0.98 cm at the rate of 0.14mm/day, and a weight gain of 13.49gm/day, albeit higher in female than their male counterparts. Nevertheless, children admitted on basis of low MUAC had a significantly higher MUAC gain than WH at 0.19mm/day and 0.13mm/day respectively. CONCLUSIONS: Mid-upper arm circumference can be an appropriate tool for identifying malnourished children for admission to nutrition rehabilitation programs. Our results confirm the appropriateness of this tool for monitoring recovery trends and discharging the children thereafter. In principle the tool has potential to minimize nutrition rehabilitation costs, particularly in community therapeutic centres in developing countries.

A Study on the New Discharge Logic Device for the Plasma Display Panels (플라즈마 디스플레이 패널을 위한 새로운 방전 논리소자에 관한 연구)

  • 염정덕;정영철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2002
  • The plasma display panel with the electrode structure of new discharge AND gate was proposed and the driving system for experiment was developed. And discharge AND gate operation was verified. Discharge AND gate operated by the operation speed of 8${\mu}\textrm{s}$ and the operation margin of 20V. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because this method uses the DC discharge, the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the input discharge and the output discharge of AND gate are separate, the display discharge can be prevented from passing AND gate. Therefore it is possible to app1y to the large screen plasma display. And the decrease of contrast ratio does not occur because the scanning discharge does not influence the picture quality.

Vertical Buoyant Jet in Tidal Water -Crossflowing Environment- (흐름 수역(水域)에서 연직상향부력(鉛直上向浮力)?)

  • Yoon, Tae Hoon;Cha, Young Kee;Kim, Chang Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.11-22
    • /
    • 1987
  • A plane buoyant jet discharged vertically upward into a crossflow is analyzed by numerical solution of the governing equations of continuity, momentum and constituent transport. The turbulent transport is modelled by the Prandtl's mixing length theory. In the numerical solution procedure, the governing equations are transformed by stream function and vorticity transport, non-dimensionalyzed by discharge velocity, slot width, and parameters representing flow characteristics, and solved by Gauss-Seidel iteration method with successive underrelaxation. The numerical experiments were performed for the region of established flow of buoyant jet in the range of discharge densimetric Froude number of 4 to 32 and in the range of velocity ratio of 8 to 15, which is the ratio of discharge velocity to crossflow velocity. Variations of velocities and temperatures, flow patterns and vorticity patterns of receiving water due to buoyant jet were investigated. Also investigated are the effects of velocity ratio and discharge densimetric Froude number on the trajectories of buoyant jet. Computed are velocities, temperatures and local densimetric Froude numbers along the trajectory of the buoyant jet. Spreading rate and dispersion ratio were analyzed in terms of discharge densimetric Froude number, local densimetric Froude number and distance from the source along the jet trajectory. It was noted that the similarity law holds in both the profiles of velocity and temperatures across the jet trajectory and the integral type analysis of Gaussian distribution is applicable.

  • PDF

Numerical Investigation for Spray Angles of Dual Swirl Injector (Dual Swirl 인젝터의 분산각에 관한 해석적 연구)

  • 정해승;김선진
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.132-144
    • /
    • 2003
  • Numerical analysis of the spray angles of Dual swirl injector were investigated to obtain basic design data and to predict the combustion performance. Using the commercial thermal hydraulic program, discharge coefficients and spray angles were numerically analyzed with recess length, pressure drop, velocity ratio, mixture ratio and back hole length. Water was used as simulants for oxidizer and fuel, respectively to compare the experimental results. Swirl injectors were designed to inject oxidizer of 70.5g/s and fuel of 29.5g/s at the pressure drop of 1MPa and two recess lengths were considered. In addition, the effect of injector geometry coefficient and velocity ratio on the discharge coefficient was studied.

A Numerical Study on the Turbulent Flow in the Discharge Flow Path from a Diffuser to a Wall (디퓨저에서 벽면으로의 방출유로에서의 난류유동에 관한 수치 해석적 연구)

  • Lee J.;Kim Y. I.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.44-50
    • /
    • 2001
  • A numerical study was made to choose the better turbulence model for the flow in the discharge flow path from a diffuser to a wall. In this study standard $\kappa-\epsilon$ model(SKE), RNG $\kappa-\epsilon$ model(RNG), and Reynolds stress model(RSM) were applied. In case of the flow with relatively high Reynolds number at a diffuser inlet, the pressure loss coefficients by RNG have a tendency to be near to those by SKE at small ratio(below about 0.35) of $h/D_o$, but to those by RSM at large ratio(above about 0.35). At large ratio RNG begins to enlarge the effects of rapid strain and streamline curvature. RNG & RSM are recommended as the appropriate turbulence models for this case. But it is noticeable that the velocity gradient pattern in RNG is same as in SKE, and also that the total pressure distribution in RNG is same as in RSM only at swirling flow area, same as in SKE only at main flow area.

  • PDF

Estimation of Upstream Ungauged Watershed Streamflow using Downstream Discharge Data (하류 유량자료를 이용한 상류유역의 미계측 유출량 추정)

  • Jung, Young Hun;Jung, Chung Gil;Jung, Sung Won;Park, Jong Yoon;Kim, Seong Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.6
    • /
    • pp.169-176
    • /
    • 2012
  • This study describes the estimation of upstream ungauged watershed streamflow using downstream discharge data. For downstream Dongchon (DC) and upstream Kumho (KH) water level stations in Kumho river basin ($2,087.9km^2$), three methods of Soil and Water Assessment Tool (SWAT) modeling, drainage-area ratio method and regional regression equation were evaluated. The SWAT was calibrated at DC with the determination coefficient ($R^2$) of 0.70 and validated at KH with $R^2$ of 0.60. The drainage-area ratio method showed $R^2$ of 0.93. For the regional regression, the watershed area, average slope, and stream length were used as variables. Using the derived equation at DC, the KH could estimate the flow with maximum 41.2 % error for the observed streamflow.

Pollutant Load Delivery Ratio for Flow Duration at the Chooryeong-cheon Watershed (추령천 유역의 유황별 유달율 계산)

  • Kim, Young-Joo;Yoon, Kwang-Sik;Son, Jae-Gwon;Choi, Jin-Kyu;Chang, Nam-Ik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.4
    • /
    • pp.19-26
    • /
    • 2010
  • To provide the basic information for the water quality management of the Sumjin River Basin, delivery ratios for flow duration were studied. Using the day-interval data set of discharge and water quality observed from the Chooryeong-cheon watershed, the flow-duration and discharge-load relation curves for the watershed were established, then the load-duration curve was constructed. Delivery ratios for flow duration were also developed. Delivery ratios showed wide variation according to flow conditions. In general, delivery ratio of high flow condition showed higher value reflecting nonpoint source pollution contribution from the forest dominating watershed. To resolve this problem, a regression model explaining the relation between flow rate and delivery ratio was suggested. The delivery ratios for different flow regime could be used for pollutant load estimation and TMDL (Total maximum daily load) development.

The study on the electrical and optical characteristics as cell spec in ac-pdp (ac-PDP에서의 셀 치수에 따른 전기, 광학적 특성에 관한 연구)

  • Moon, Young-Seop;Lee, Sung-Hyun;Lim, Sung-Hyun;Shin, Choong-Hong;Yoo, Choong-Hee;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1582-1584
    • /
    • 2001
  • In ac plasma display(PDP), an image quality mainly depends on the contrast ratio. And the contrast ratio is affected by the driving condition and size of discharge cell. In this study, the electrical and optical characteristics during reset, address and sustain discharge were investigated as the height and width of barrier rib were varied in order to obtain the highest contrast ratio. As a result, the optimum rib height and width were 140${\mu}m$ and 600${\mu}m$, respectively.

  • PDF

A Study on the Two-Phase Flow Transition and Atomization Characteristics in Effervescent Injectors (기체주입식 분사기의 이상유동 변화와 분무특성에 관한 연구)

  • Lee, Kangyeong;Jung, Hadong;Kang, Cheolwoong;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.27 no.3
    • /
    • pp.144-154
    • /
    • 2022
  • Gas injection is a technique applied to improve throttling in liquid rocket engines and atomization in effervescent injectors. When a gas is injected into a liquid, it creates a two-phase flow inside the injector. The changes (bubbly flow, slug flow, annular flow, etc.) in the two-phase flow affect the injector's spray characteristics. In this study, cold-flow tests were performed by using three injectors with different orifice diameters and four aerators with different gas injection hole diameters. The experiments were done by changing the thrust ratio (liquid mass flow rate ratio) and gas-liquid mass flow rate ratio. Two-phase flow transition, breakup length, and discharge coefficient according to the injector/aerator design and flow conditions were investigated in detail.

A Study of the Method for External Noise Shielding using the GIS UHF Sensor Module Applied to the Partial Discharge Signal Sensitivity and Method of Frequency Transforming in the Internal GIS (GIS내부의 부분방전신호 감도개선 및 주파수변환기법에 의한 GIS UHF Sensor 모듈의 외부노이즈차폐기법에 관한 연구)

  • Lee, Seung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.728-732
    • /
    • 2010
  • GIS(Gas insulated switching gear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. Recently, because equipment of GIS was occurring problem of confidence used for a long time, partial discharge on-line diagnosis systems have been importantly recognized. Partial discharge (PD) detection is an effective means for monitoring and evaluation of dielectric condition of gas insulated system (GIS). The ultra-high-frequency (UHF) PD detection technique can detect and locate the PD sources inside GIS by detecting electromagnetic wave emitted from PD source. Therefore, real-time diagnostic system using UHF detection method has been developed for this application is being expanded gradually. However, the signal of partial discharge occurring in SF6 gas is very weak and susceptible to external noises which mainly consist of PD in air. Thus, it is important to distinguish the PD in SF6 gas more sensitively from the external noises. Unfortunately, these external noise signals and the partial discharge signals have very similar characteristics. Therefore, to solve this problem, we need the signal processing method for distinguish partial discharge signals with external noise signals for improvement of SNR(signal to noise ratio) and sensitivity. In this paper, we proposed internal signal processing method for removing external noise signals with built-in pre.amplifier and frequency conversion circuit.