• 제목/요약/키워드: Discharge pressure measurement

검색결과 103건 처리시간 0.028초

리스크 완화를 위한 Wet Scrubber 세정수 pH의 효율적 관리 (Efficient Management of the pH of the Wet Scrubber Washing Water for Risk Mitigation)

  • 주동연;서재민;김명철;백종배
    • 한국안전학회지
    • /
    • 제35권6호
    • /
    • pp.85-92
    • /
    • 2020
  • Wet Scrubber reacts the incoming pollutant gas with cleaning water (water + absorbent) to absorb pollutants and release the clean air to the atmosphere. Wet scrubbers and packed tower scrubbers using this principle are widely used in businesses that emit acid gases. In particular, in the etching process using hydrochloric acid (HCl), alkaline washing water (NaOH) having a pH of about 8 to 11 is used to absorb a large amount of acid gas. However, These salts are attached to the injection nozzle (nozzle), filling material (packing), and the demister (Demister), causing air pollution, human damage, and inoperability due to clogging and acid gas discharge. Therefore, In this study, an improvement plan was proposed to manage the washing water with pH 3~4 acidic washing water. The test method takes samples from the Wet Scrubber flue measurement laboratory twice a month for 1 year. Hydrogen chloride (HCl) concentration (ppm) was measured, and nozzle clogging and scale conditions were measured, compared, and analyzed through a differential pressure gauge and a pressure gauge. As a result of the check, it was visually confirmed that the scale was reduced to 50% or less in the spray nozzle, filler, and demister. In addition, the emission limit of hydrogen chloride in accordance with the Enforcement Regulation of the Air Quality Conservation Act [Annex 8] met 3 ppm or less. Therefore, even if the washing water is operated in an acidic pH range of 3 to 4, it is expected to reduce air pollution and human damage due to clogging of internal parts, and it is expected to reduce maintenance costs such as regular cleaning or replacement of parts.

댐 방류 경보방송의 전달 특성 및 적정 위치 선정에 관한 연구 (A Study on Travelling Characteristics and Choice of Proper Location of Dam Discharge Alarm Broadcasting)

  • 김대군;김재수
    • 대한환경공학회지
    • /
    • 제31권8호
    • /
    • pp.635-640
    • /
    • 2009
  • 1960년대 이후 연강수량의 변동 폭이 커짐에 따라 유량조절을 통해 가뭄과 홍수를 방지하기 위한 댐이 건설되었다. 이러한 댐의 경우, 일정 저수량이 되면 수량을 조절하기 위해 수문을 개방하여 저수지 내 많은 양의 물을 방류하게 되는데 이 때 강 또는 강 주변의 주민 및 행락객들의 생명과 재산 등의 큰 피해가 발생할 수 있다. 따라서 이러한 피해를 예방하고 알리기위해 울리는 경보방송은 방류소음이나 주변의 환경적인 요인에 영향을 받지 않고 사람들에게 명료하게 전달될 수 있어야 하지만 지금까지 별다른 연구없이 경험적으로 설치하다보니 경보방송이 효과적으로 전달되지 못하고 그 전달거리 또한 정확히 알수 없었다. 이러한 관점에서 본 연구는 다목적 댐 중의 하나인 대청댐의 방류소음과 경보방송의 거리별 측정 및 분석을 통하여 주파수별 특성과 음압레벨을 파악해보고 이를 토대로 Cadna-A라는 시뮬레이션 프로그램을 이용하여 추가 경보방송지의 적정위치를 예측해 보았다. 이러한 결과는 향후 경보방송의 설계 및 설치시 유용한 자료를 제공할 것으로 사료된다.

전화를 이용한 퇴원환자 만족도 조사 (The Measurement Of Postdischarge Patient Satisfaction Using Telephone Interview)

  • 송정흡
    • 한국의료질향상학회지
    • /
    • 제4권1호
    • /
    • pp.104-114
    • /
    • 1997
  • Background : Hospitals(Health care providers) are under tremendous pressure to meet consumer demands in order to compete in the rapidly changing health care arena. Through evaluating patient satisfaction, hospitals(health care providers) can learn what the consumer Wants from the health care system. Timely feedback is necessary. The purpose of this study is to evaluate patients' hospital experience and satisfaction using telephone interview and to study the usefulness for telephone interview at assessing patient satisfaction. Method : The 846 patients who were discharged from September 17, 1996 to October 11, 1996 were targeted were telephoned. The informations gathered telephone survey were processed by computer and analyzed for the patient satisfaction, contributing factors. Result : The 846 patients who were discharged from September 17, 1996 to October 11, 1996 were called and 197 patients(23.3%) were successful interviewed. 51.3 percent of respondents were male and mean age is 39 years mean LOS(length of stay) is 13 days and 110(56.1%) patients were admitted by outpatients clinic. The mean calling-time is 5.5 minutes. There is no significant difference between interviewers(telemarketer) in patients satisfaction. Seven telephone interviews are possible by interview a day. There in no significant difference between groups in patients satisfaction in length of stay, path of admission, the interval between discharge and interview. 97.5 percent of respondents were satisfied with telephone interview and 81.7% were satisfied with overall satisfaction and 79.4 % of respondents were good response in interviewers' conclusion. Of six variables that were found to be correlated with telephone interview and eight variables correlated with overall hospital satisfaction, a multiple logistic regression analysis revealed that two most important variables which are significantly correlated with telephone interview are to meet doctors, not ask tediously then three variables which are with overall satisfaction are doctors explain, subject response, convenient facilities. Conclusion : The patients interviewed are satisfied with telephone interview. Telephone interview is good method for assessing patient satisfaction, making high levels of patient satisfaction and for hospital marketing.

  • PDF

암모니아 추가 주입에 의한 배열회수보일러 급수의 수소이온농도 조절 (pH Control of Feed Water for HRSG with Additional Injection of NH3)

  • 목용강;문승재;이재헌
    • 플랜트 저널
    • /
    • 제11권2호
    • /
    • pp.32-38
    • /
    • 2015
  • 탈기기-저압드럼 일체형 배열회수보일러로 구성된 복합화력발전소에서 발생한 저압증기발생기의 튜브파손 사례를 관찰하였다. 수소이온농도 변화를 관찰한 결과 복수펌프 후단에 주입된 암모니아가 탈기기를 통과한 후 저압 드럼 내에서 암모니아 분배율에 따라 증기와 함께 다량의 암모니아가 소모되어 급수 내 수소이온농도 저하를 확인하였다. 이를 해결하기 위해 저압드럼 내에 암모니아를 직접 주입할 수 있도록 추가 주입위치를 선정하였으며 적정량의 암모니아 용액을 주입함으로써 보일러 급수의 최적 수소이온농도인 9.2~9.6 으로 조절이 가능하다는 결론을 얻었다.

  • PDF

Controlling the surface energy and electrical properties of carbon films deposited using unbalanced facing target magnetron sputtering plasmas

  • Javid, Amjed;Kumar, Manish;Yoon, Seok Young;Lee, Jung Heon;Han, Jeon Geon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.231.1-231.1
    • /
    • 2015
  • Surface energy, being an important material parameter to control its interactions with the other surfaces plays a key role in bio-related application. Carbon films are found very promising due to their characteristics such as wear and corrosion resistant, high hardness, inert, low resistivity and biocompatibility. The present work deals with the deposition of carbon films using unbalanced facing target magnetron sputtering technique. The discharge characteristics were studied using optical emission spectroscopy and correlated with the film properties. Surface energy was investigated through contact angle measurement. The ID/IG ratio as calculated from Raman spectroscopy data increases with the increase in power density due to the higher number of sp2 clusters embedded in the amorphous matrix. The deposited films were smooth and homogeneous as observed by Atomic force microscopy having RMS roughness in the range of 1.74 to 2.25 nm. It is observed that electrical resistivity and surface energy varies in direct proportionality with operating pressure and has inverse relation with power density. The surface energy results clearly exhibited that these films can have promising applications in cell cultivation.

  • PDF

사냑형 간섭계 광섬유 센서를 이용한 변압기유 내에서의 외부 음향 주파수 모니터링 (Applied Sound Frequency Monitoring in the Transformer Oil Using Fiber Optic Sagnac Interferometer)

  • 이종길;이승홍
    • 한국음향학회지
    • /
    • 제34권4호
    • /
    • pp.288-294
    • /
    • 2015
  • 광섬유 사냑 간섭계는 음향 및 진동과 같은 물리적 변화량을 탐지하는 센서로 잘 개발되어 있다. 본 논문에서는 변압기유가 채워진 원통형 캐비티에 음압이 발생되었을 때 한 개의 루프내에 설치된 광섬유 배열 센서를 이용하여 음향을 탐지하였다. 서로 다른 외부 음향 주파수 $f_1$$f_2$를 피에조 재료를 이용하여 발생시키고 주파수는 5 kHz에서 90 kHz까지로 선정하였다. 실험 결과 광섬유 센서는 하모닉 성분인 $f_1$, $f_2$, $2f_1$, $2f_2$, ${\mid}f_1-f_2{\mid}$, ${\mid}f_1+f_2{\mid}$의 주파수를 탐지하였다. 제안된 광섬유 센서 배열은 변압기 내의 부분 방전으로 인한 음압과 진동과 같은 물리량을 모니터링 하는데 적용할 수 있을 것으로 판단된다.

아르곤/이산화탄소 혼합가스의 유도 결합 플라즈마를 이용한 이산화탄소 분해 연구 (Study on CO2 Decomposition using Ar/CO2 Inductively Coupled Plasma)

  • 김경현;김관용;이효창;정진욱
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.135-140
    • /
    • 2015
  • 유도 결합 플라즈마를 활용하여 $Ar/CO_2$ 혼합가스에서 이산화탄소를 분해하는 연구이다. 고밀도 플라즈마를 발생시키기 위해 Ar 가스를 첨가하였고 이산화탄소 분해율을 측정하기 위해 광학적 광량 측정법을 사용 하였다. 유도 결합 플라즈마를 방전시키고 인가 전력, 압력, 혼합가스 비율을 변경하가며 단일 랭뮤어 프로브를 이용해 플라즈마 변수를 얻고 방출 분광기로 얻은 빛의 스펙트럼을 이용하여 분해율을 측정하였다. 측정된 플라즈마 변수로부터 $CO_2$ 유도 결합 플라즈마의 소스 특성을 확인했고 $CO_2$ 분해 메커니즘은 플라즈마 변수에 직접적인 영향을 받기 때문에 그 상관관계를 분석하였다.

High Performance ESD/Surge Protection Capability of Bidirectional Flip Chip Transient Voltage Suppression Diodes

  • Pharkphoumy, Sakhone;Khurelbaatar, Zagarzusem;Janardhanam, Valliedu;Choi, Chel-Jong;Shim, Kyu-Hwan;Daoheung, Daoheung;Bouangeun, Bouangeun;Choi, Sang-Sik;Cho, Deok-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권4호
    • /
    • pp.196-200
    • /
    • 2016
  • We have developed new electrostatic discharge (ESD) protection devices with, bidirectional flip chip transient voltage suppression. The devices differ in their epitaxial (epi) layers, which were grown by reduced pressure chemical vapor deposition (RPCVD). Their ESD properties were characterized using current-voltage (I-V), capacitance-voltage (C-V) measurement, and ESD analysis, including IEC61000-4-2, surge, and transmission line pulse (TLP) methods. Two BD-FCTVS diodes consisting of either a thick (12 μm) or thin (6 μm), n-Si epi layer showed the same reverse voltage of 8 V, very small reverse current level, and symmetric I-V and C-V curves. The damage found near the corner of the metal pads indicates that the size and shape of the radius governs their failure modes. The BD-FCTVS device made with a thin n- epi layer showed better performance than that made with a thick one in terms of enhancement of the features of ESD robustness, reliability, and protection capability. Therefore, this works confirms that the optimization of device parameters in conjunction with the doping concentration and thickness of epi layers be used to achieve high performance ESD properties.

Evaluation of Nonthermal Plasma Treatment by Measurement of Stored Citrus Properties

  • Seo, Youngwook;Park, Jong-Ryul;Park, Hoe Man
    • Journal of Biosystems Engineering
    • /
    • 제43권4호
    • /
    • pp.401-409
    • /
    • 2018
  • Decay of fruit is one of the greatest issues in fruit storage. Purpose: In this study, citrus sterilization was performed to evaluate a dry sterilization method using an atmospheric-pressure nonthermal plasma treatment based on a dielectric-barrier discharge technique. Methods: Citrus samples were stored under four different environmental conditions as follows: group A had cold storage with plasma treatment with a temperature of $6.2{\pm}1.0^{\circ}C$ and relative humidity (RH) of $93.4{\pm}8.2%$, group B had ambient-temperature storage with $22.9{\pm}2.3^{\circ}C$ and $82.1{\pm}4.5%$ RH, group C ambient-temperature storage with plasma treatment with $25.3{\pm}2.2^{\circ}C$ and $90.0{\pm}2.8%$ RH, and group D had cold storage with $5.7{\pm}1.0^{\circ}C$ and $93.4{\pm}6.5%$ RH. Results: As a result of citrus surface sterilization by plasma treatment, treatment groups A and C together showed an average of 16.1 CFU/mL of mold colonies, while control groups B and D showed an average of $2.2{\times}10^2CFU/mL$ or approximately 13 times greater than the treatment groups. Regarding the mean concentration of aerobic bacteria colonies, the treatment groups (A and C) and control groups (B and D) showed an average of 7.1 CFU/mL and $1.9{\times}10^3CFU/mL$, respectively. This is approximately a 270-fold difference in the concentration of pathogen colonies between treatment and control groups. Conclusions: The results showed the potential of nonthermal plasma treatment for citrus storage in enhancing storage duration and quality preservation.

기능성 소화불량 환자에 대한 한의복합치료 효과 : NDI-K(Nepean Dyspepsia Index-Korean version)를 통한 기능성 소화불량증상, algometer를 통한 압력통각역치 측정을 통하여 (The Effect of Korean Medical Complex Treatment on Functional Dyspepsia Patients : Through Measurement of Functional Dyspepsia Symptoms through NDI-K (Nepean Dyspepsia Index-Korean Version), Pressure Pain Threshold through an Algometer)

  • 노기환;최규호;이상현;최서형;노현민
    • 동의생리병리학회지
    • /
    • 제36권3호
    • /
    • pp.100-104
    • /
    • 2022
  • The purpose of this study is to observe the effectiveness of the Korean medical complex treatments for functional dyspepsia (FD). And we observed NDI-K (Nepean dyspepsia index-Korean version) and algometer on acupoints to confirm the treatment effectiveness. In this retrospective study, we investigated 77 patients with FD symptoms who admitted to 00 Korean Hospital for 2 weeks from April 14, 2020 to March 31, 2021. All patietns were treated with herbal medicines, acupuncture, pharmacopuncture, moxa treatment, aroma therapy, So-jeok and So-jeok II therapy. On the day of admission and discharge, NDI-K, algometer on acupoints (CV12, CV10, ST25, ST27, SP14) were examined twice. Among the NDI-K values, all 14 items except for poor breathing were decreased statistically significantly. The algometer values were increased statistically significantly in all acupoints (CV12, CV10, ST25, ST27, SP14). These results suggest that Korean medical treatment can be useful in the treatment of FD.