• 제목/요약/키워드: Discharge of cold

검색결과 160건 처리시간 0.031초

냉음극 방전관의 기동특성 안정화에 관한 연구 1

  • 지철근
    • 전기의세계
    • /
    • 제14권3호
    • /
    • pp.18-27
    • /
    • 1965
  • It is well known that the starting characteristics of the cold cathode type discharge tubes are irregular. We have two kinds of stabilization for starting characteristics of discharge tubes. Which are the aging test immediately after producing the tubes and the using characteristics. This paper was devoted primaliry to the empric study of relation between the aging and the manufacturing process. And then to stabilize the starting characteristics of discharge tubes by the irradiations of radio-isotope.

  • PDF

전단동축형 분사기의 유량계수에 대한 형상학적 변수들의 영향 (Effect of Geometrical Parameters on Discharge Coefficients of a Shear Coaxial Injector)

  • 안종현;이근석;안규복
    • 한국분무공학회지
    • /
    • 제25권3호
    • /
    • pp.95-102
    • /
    • 2020
  • Six shear coaxial injectors for a 3 tonf-class liquid rocket engine using oxygen and methane as propellants were designed and manufactured by considering geometric design parameters such as a recess length and a taper angle. Cold-flow tests on the injectors were performed using water and air as simulants. By changing the water mass flow rate and air mass flow rate, the injection pressure drop under single-injection and bi-injection was measured. The discharge coefficients through the injector oxidizer-side and fuel-side were calculated and the discharge coefficient ratio between bi-injection and single-injection was obtained. Under single-injection, the recess served to reduce the injection pressure drop on the injector fuel-side. For the injectors without recess, the discharge coefficients under bi-injection were almost the same as those under single-injection. However, for the injectors with recess, the taper angle and bi-injection had a significant effect on the discharge coefficient.

방전유 분사시스템에 의한 냉간금형용 합금강의 형조방전가공 (Die-singing Electrical Discharge Machining of Cold Die Alloy Steel with Dielectric Fluid Djection System)

  • 우정윤
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.473-477
    • /
    • 2000
  • The experimental study of die-sinking electrical discharge machining(EDM) was conducted for Cold Die Alloy Steel of SKD-11 with rotary electrode according to the peak current of 11A, 15A and 19A, and the duty factor of 0.24, 0.45. dielectric fluid flow through the electrode inside according to the change of electrode internal diameter during the EDM working. Material removal rate(MRR) was increased with flushing & rotation of electrode at the condition for the peak current of 15A, 19a but the MRR is decreased at the flushing only. The more surface roughness was obtained for the case of the flushing & rotation under the peak current of 19A.

  • PDF

오리피스 형상에 따른 발사관 내 부가추력 특성 연구 (Analysis of the Thrust Augmentation in the Canister with Baseplate Orifices)

  • 윤진영;임범수
    • 한국군사과학기술학회지
    • /
    • 제14권6호
    • /
    • pp.1067-1072
    • /
    • 2011
  • If the flow of booster gas which is exhausted to the rear part of a canister is properly restricted in the canister of a hot-launch system, the resultant pressure built up in the canister provides additional force to accelerate the missile to a required launch velocity. These thrust augmentation performances can be controlled through the configuration design of baseplate orifices. In this paper, the simple technique to analyze the thrust augmentation performances of baseplate orifices is suggested and the thrust augmentation characteristics by its various configurations are compared. According to the initial displacement of a missile, the inner pressure of a canister is measured from scaled cold flow tests, and the discharge coefficient of baseplate orifices is calculated. Then the thrust augmentation in a canister is simulated by applying these discharge characteristics to the AMESIM software for launch dynamics.

냉간 금형용 공구강의 Cu 전극을 이용한 방전 탭에 관한 연구 (A Study on the Electrical Discharge Machining Tap by using Cu Electrodes of the Cold-Work Tool Steel)

  • 이은주;박인수;김후권;왕덕현;정한식;이광성
    • 한국기계가공학회지
    • /
    • 제15권5호
    • /
    • pp.131-136
    • /
    • 2016
  • Currently, an EDM tapping procedure has comprised some parts of the engraving discharge process for the press die. Usually, tapping has been used in cases where we are unable to mechanically machine using steelwork processes due to an increase in the hardness of a material after heat treatment in relation to a design change or missing process. Here, we analyze the influence of discharge tap shape on discharge time, discharge current, and the number of repetition conditions when a cold-work tool steel (STD11) has been treated with a discharge tapped by a screw-shaped cu electrode. The most important influence on processing condition has been determined to be the number of discharge repetitions. As this number increases, the angle reduction of a thread closes to an angle of the electrode via a power generation reduction. The optimal combination of conditions has been determined to be three discharge repetitions, $180{\mu}s$ of discharge time (same as existing regulations), and 25.4A of peak current. A 0.2749db advantage has emerged after comparing between this combination of optimal conditions and the SN rate of existing regulations.

하절기(夏節期)와 동절기(冬節期)의 감모환아(感冒患兒)에 대한 임상적(臨床的) 고찰(考察) (The Clinical Study in Children with Common Cold (in summer & winter))

  • 구진숙;백정한
    • 대한한방소아과학회지
    • /
    • 제16권2호
    • /
    • pp.101-110
    • /
    • 2002
  • The common cold is the most common pediatric infectious disease and occupies a great number of outpatients in oriental pediatrics. Because children's common cold has characteristic symptoms, we studied 276 children suffering from common cold Oriental Medicine Hospital in Kyungsan University and analyzed sex, age, chief complaints, characteristic symptoms.(period : summer 2001. 6.1.-2001.8.31, winter 2001.12.1-2002. 2. 28) The results were as follows : 1. Male to female ratios were 17: 1 in summer, 1.2: 1 in winter, 1.4: 1 in total 2. Age distribution of children from 0 to 1 was 20.29%, from 1 to 3 was 39.49%, from 3 to 6 was 32.97%, from 6 to 10 was 7.27%, over 10 was 0%, from 0 to 6 was 92.75%. 3. Frequency of chief complaints In summer : cough was 22.28%, nasal discharge was 18.39%, fever was 16.58%, secretion and sputum were 14.50%, sweating was 6.99%, nausea or vomitting were 4.92% etc. In winter : cough was 24.20%, nasal discharge was 18.03%, secretion and sputum were 16.43%, occlusion of nares was 11.64%, fever was 9.58%, nausea or vomitting were 3.88% etc. Frequency of chief complaints has seasonal difference. 4. Children's common cold has characteristic symptoms and seasonal difference. 5. Children's common cold has characteristic clinical subtype.

  • PDF

축냉 시스템이 차 실내 열 쾌적성에 미치는 영향에 관한 실험적 연구 (Experimental Study of the Effect on Cabin Thermal Comfort for Cold Storage Systems in Vehicles)

  • 이대웅
    • 한국자동차공학회논문집
    • /
    • 제23권4호
    • /
    • pp.428-435
    • /
    • 2015
  • This paper presents the experimental study of cabin thermal comfort using a cold storage heat exchanger in a vehicle air-conditioning system. Recent vehicle-applied ISG functions for fuel economy and emission, but when vehicles stop, compressors in the air-conditioning system stop, and the cabin temperature sharply increases, making passengers feel thermal discomfort. This study conducts thermal comfort evaluation in the vehicle, which is applied to a cold storage system for the climate control wind tunnel test and the vehicle fleet road test with various airflow volume rates and ambient temperatures blowing to the cold storage heat exchanger. The experimental results, in the cold storage system, air discharge temperature is $3.1-4.2^{\circ}C$ lower than current air-conditioning system when the compressor stops and provides cold air for at least 38 extra seconds. In addition, the blowing airflow volume to the cold storage heat exchanger with various ambient temperature was examined for the control logic of the cold storage system, and in the results, the airflow volume rate is dominant over the outside temperature. For this study, a cold storage system is economically useful to keep the cabin at a thermally comfortable level during the short period when the engine stops in ISG vehicles.

빙축열을 이용한 저온공조시스템 운전 특성 연구 (Study on operation characteristics of the cold air distribution systems with an ice storage tank)

  • 염한길;박병규;고득용
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.301-312
    • /
    • 1999
  • Experiments were carried out to evaluate performance of the cold air distribution systems with an ice storage tank in test room. Cold air distribution systems provide primary air for comfort conditioning or process cooling at coil discharge temperatures$4^{\circ}C$ to$11^{\circ}C$. The application of a cold air distribution system allows for the downsizing of air distribution equipment and central plant equipment when ice storage tank is used. The benefit of a cold air distribution system include a decrease in the floor-to-floor height, increase floor space, reduced building capital costs, reduced energy use and demand. The use of cold air distribution can result in the most cost effective system and is currently being implemented world wise as the new standard in air conditioning systems. In this study, the cold air distribution system is compared with the general ice storage system. Under the same cooling load conditions, experimental results show that the supply air volume of cold air distribution system decrease 38%, and decrease 45% flow rate of brine for the general ice storage system.

  • PDF

난방공간에서 에어커튼의 토출각도 변화에 따른 성능 변화 (Performance Variation of the Air Curtain for Various Discharge Angles in Feating Space)

  • 성순경
    • 설비공학논문집
    • /
    • 제22권2호
    • /
    • pp.57-63
    • /
    • 2010
  • Air curtains are widely used for gates of shopping mall, warehouse, cold stores and refrigerated display cabinets. The purpose of the air curtain is to reduce the infiltration of outdoor air and heat loss from the air conditioning space to ambient air. The discharge angle of air curtain is very important as the sealing efficiency is affected by it. This paper presents a performance of single jet air curtain in heating space when the discharge angle of nozzle changes. A numerical simulation is used to study the influence of various parameters on the efficiency of the downward-blowing air curtain device which is installed inside of the wall above the door. The performance of the air curtain is evaluated by sealing efficiency which provides the assessment of the energy savings. A condition of discharge angle that has the highest sealing efficiency is proposed.

Development and Test of ion Source with Small Orifice Cold Cathode

  • G. E. Bugrov;S. K. Kondranin;E. A. Kralkina;V. B. Pavlov;K. V. Vavilin;Lee, Heon-Ju
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제5권1호
    • /
    • pp.19-24
    • /
    • 2001
  • The paper represents the results of the development and the test of "cold cathode" ion source model with 5 cm aperture where the glow discharge is utilized for generation of electrons in the cathode of the ion source. The results of probe measurements of the ion source are represented. The integral parameters such as electron energy distribution function(EEDF), electron density and mean electron energy, discharge voltage-current characteristics, and distribution of ion beam were studied.

  • PDF