• Title/Summary/Keyword: Discharge needle

Search Result 211, Processing Time 0.032 seconds

1-Dimensional Simulation of the Corona Discharge using Fluid Method (유체법을 이용한 코로나 방전의 1차원 수치해석)

  • 이용신;심재학;고광철;강형부
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.172-176
    • /
    • 1997
  • It is likely that the corona discharge appears due to the motion and the multiplication of electron and ion under the nonuniform electric field. Because the motion and the multiplication of electron and ion are the function of electric field, for the simulation of the corona discharge, we have to calculate the electric field, before the calculation of the motion and the multiplication of electron and ion. In this paper, the electric field is calculated on the assumption that the gap between a hyperboloidal needle and a plane is 1-dimension, and the motion and the multiplication of electron and ion are determined by Flux-Corrected Transport method. For this purpose, we solve the electron and ion continuity equation together with Poisson equation. We calculated the current density and the electron and ion density distributions between electrodes as well as electric field distortion due to the space charge assuming that the discharge channel radius is 100${\mu}{\textrm}{m}$. In this simulation, it is found that the current density has one peak as observed by experiment, and electric field distortion is important to the formation and the stability of the corona discharge.

  • PDF

Discharge characteristics of FFL as the variation of cell structure (셀 구조 변화에 따른 FFL(Flat Fluorescent Lamp)의 방전특성)

  • 윤성현;박철현;조민정;임민수;권순석;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.600-603
    • /
    • 2000
  • Recently, Display devices have become important in the information-oriented society and flat display devices are greatly demanded. Liquid crystal display(LCD) represents one of the most promising devices for large size desk-top monitors, notebook PC and car navigation system. However LCD cannot give forth light itself and must have backlight system. The most popular backlighting system is composed of a lighting-guide plate and CCFL as a lighting source. The number of CCFL must increase up if the area of display is increased. So a new backlighting source with high luminance is needed for large LCDs. In this paper, we proposed a surface discharge FFL with the new electrode structure like the needle shaped electrode as the variation of cell structure to high luminance and low power consumption. In comparison with different electrode structure it has low discharge voltage and current and good optical characteristics. So it has better discharge characteristics than different surface discharge FFL and can be fungible for a backlight as a lighting source in LCDs.

  • PDF

The induced discharge characteristics in atmosphere adopting a pulsed $CO_2$ laser (펄스형 $CO_2$ 레이저를 이용한 기중 침 대 침 전극간의 유도방전 특성)

  • Jung, Yong-Ho;Choi, Jin-Young;Lee, Yu-Soo;Chung, Hyun-Ju;Song, Gun-Ju;Kim, Hee-Je
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.172-175
    • /
    • 2002
  • The technique of induced discharge by a pulsed CO2 laser is being applied to control electrical discharge path, material processing, triggered lightning for protecting the power equipments. In this paper, we have investigated about the characteristics of the induced discharge at atmospheric conditions by using a plasma channel, which is produced when a pulsed CO2 laser radiation is focused by a focusing mirror as a trigger source. A plasma channel produced by laser radiation has an effect on decreasing the threshold voltage and inducing the discharge in both needle electrodes. We have confirmed a delay time between a produced plasma channel and an electrical discharge after laser radiation. We provided the decreased voltage lower than the natural discharge voltage between electrode type of needles and was induced the discharge by forming a plasma channel between them. In this research we could understand the time delay of induced discharge by laser radiation, and the characteristics of the discharge cause by the decrease in the threshold voltage, and the polarity effect by changes of plasma channel positions between two electrodes.

  • PDF

Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields (균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성)

  • Kim, Tae-Ki;Kim, Seung-Min;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.

Transient Ground Impedance of Small-sized Needle-rod Electrodes due to Underground Soil Discharge (토양의 지중방전에 따른 소형 침봉전극의 과도접지임피던스)

  • Lee, Tae-Hyung;Cho, Sung-Chul;Eom, Ju-Hong;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.211-215
    • /
    • 2008
  • This paper deals with the transient ground impedance of small-sized needle-rod installed in a test field, Impulse voltage generator was used to inject lightning impulse on a ground electrode and modified fall-of potential method was proposed to measure the high ground potential rise. Transient ground impedance was analysed with impedance curve and I-V curve as respects the resistivity of soil. Soil ionization near the ground electrode is activated in high resistivity soil and have an effect on the reduction of transient ground impedance significantly.

  • PDF

A Characteristics of UV images and PD quantity at Needle-Plane electrodes (침대평판 전극에서의 부분방전량과 자외선 이미지 특성)

  • Shong, Kil-Mok;Kim, Young-Seok;Park, Sang-Taek
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.101-104
    • /
    • 2009
  • In this paper, it's described the techniques for the analysis of corona generated in open live parts of electric facilities. At needle-plane electrodes, when the voltage increased($0{\sim}70kV$, ramping 10kV) using the high voltage generation system(HIPOTRINICS $0{\sim}200kV$, USA), it's generated the partial discharge. There are compared between UV detected image and PD quantity. As these results, UV areas and gains are normalized. And electric facilities are evaluated the 5 steps such as 'good', 'recognition', 'check', 'inspection', 'change(replacement)'.

  • PDF

Soil Discharge Characteristics in Inhomogeneous Field Caused by Lightning Impulse Voltages (뇌임펄스전압에 의한 불평등전계에서 토양방전특성)

  • Yoo, Yang-Woo;Kim, Seung-Min;Kim, You-Ha;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.95-101
    • /
    • 2015
  • This paper presents experimental results about characteristics of soil discharge as a function of moisture content when the $1.2/50{\mu}s$ lightning impulse voltage is applied. The laboratory experiments, for this study, were carried out based on factors affecting the transient behavior in soils. The electrical breakdown in soils was measured over a 0-6% range of moisture content for sands and a 0-4% range of moisture content for gravels. Needle-plane electrode systems was used As a result, the conduction current prior to ionization growth in dry soil is a little, but it in wet soil is increased with the applied voltage because the wet soil particles act as conductors. The soil impedance curves show an abrupt reduction just after breakdown. The general tendency measured in different soils is that the higher the water content, the lower the breakdown voltage and the shorter the time-lag to breakdown.

The Measurment and Analysis of Electromagnetic Waves by Discharge in Air (기중방전에 대한 방사전자파 측정과 분석)

  • Lee, Sang-Hoon;Park, Kwang-Seo;Kim, Chung-Nyen;Kim, Ki-Chai;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2028-2030
    • /
    • 1999
  • In this paper, partial discharge(PD) was generated under the two types of needle -plane electrodes in the air. Using a monopole antenna to detect the radiated electromagnetic waves by stream of charge between the electrodes. the progress of partial discharge was studied. To analyze the progress of PD, statistical re-search was introduced. It was executed by personal computer and it can be possible to visualize the progress of PD. The t-test was used for lower voltage applied. The population of background noise spectrum and applied voltage spectrum showed the difference. The new method was introduced to analyze the spectrum. According tho the magnitude of applied voltage, the different statistical methods were used. The results obtained from this work will provide the useful information on partial discharge in time to come.

  • PDF

Frequency Spectrum Analysis of Series Arc and Corona Discharges (직렬 아크 및 코로나 방전의 주파수 스펙트럼 분석)

  • Kil, Gyung-Suk;Jung, Kwang-Seok;Park, Dae-Won;Kim, Sun-Jae;Han, Ju-Seop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.7
    • /
    • pp.554-559
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of radiated electromagnetic pulses generated by series arc- and corona- discharges as a basic study to develop an on-line diagnostic technique for power facilities installed inside closed-switchboards. To simulate series arc and corona discharges, five types of electrode system which consists of needle and plane electrodes were arranged. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of an ultra log antenna and an EMI receiver. From the experimental results, the frequency spectrum exists in ranges from 30 MHz to 2 GHz for a series arc discharge and 30 MHz to 1.2 GHz depending on defects for a corona discharge. The peak frequency of the series arc- and corona- discharges were 100 MHz to 160 MHz and 40 MHz to 80 MHz, respectively.

An internal partial discharge measurement method excepted an external corona noise (외부 코로나 노이즈를 제거한 내부 부분방전 측정기법)

  • 권동진;진상범;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.44-50
    • /
    • 2001
  • The largest problem in applying the elecbical partial discharge measurement method the transformer that has been operated until now is the removal of external corona noise In this thesis, a methcd was studied. to rneasme only fue partial discharge sIgnal due to the defoct in transfonrer except the external corona noise. To find out the types of partial discharge and corona noise within a transfomr, a partial discharge was made in use of a needle-plane electrodes within a model transfonner and, at the same time, an external corona noise was generated in use of a rod-sphere electrcdes in the air around the transformer. Both of a partial clischarge signal caused from an intemat defect within a transformer and an external noise were found at the rogowski coil which was located at transformer earth wire. When the external corona noise, which was separately measured in use of an antenna sensor out of transfonner, was removed from the signal measured on rogowski coil, the signal caused by partial discharge within a transformer would effectively be acquired.quired.

  • PDF