• 제목/요약/키워드: Discharge machining

검색결과 324건 처리시간 0.029초

Detection of Deep Subsurface Cracks in Thick Stainless Steel Plate

  • Kishore, M.B.;Park, D.G.;Jeong, J.R.;Kim, J.Y.;Jacobs, L.J.;Lee, D.H.
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.312-316
    • /
    • 2015
  • Unlike conventional Eddy Current Test (ECT), Pulsed Eddy Current (PEC) uses a multiple-frequency current pulse through the excitation coil. In the present study, the detection of subsurface cracks using a specially designed probe that allows the detection of a deeper crack with a relatively small current density has been attempted using the PEC technique. The tested sample is a piece of 304 stainless steel (SS304) with a thickness of 30mm. Small electrical discharge machining (EDM) notches were put in the test sample at different depths from the surface to simulate the subsurface cracks in a pipe. The designed PEC probe consists of an excitation coil and a Hall sensor and can detect a subsurface crack as narrow and shallow as 0.2 mm wide and 2 mm deep. The maximum distance between the probe and the defect is 28 mm. The peak amplitude of the detected pulse is used to evaluate the cracks under the sample surface. In time domain analysis, the greater the crack depth the greater the peak amplitude of the detected pulse. The experimental results indicated that the proposed system has the potential to detect the subsurface cracks in stainless steel plates.

와이어 컷 방전가공 조건에 따른 STD-11 Die-hole 가공시 진직정밀도 고찰 (The study on the Straightness forms of STD-11 Die-hole in wire-cut Electronic Discharge Machining Conditions)

  • 조규재;김선진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.739-742
    • /
    • 2000
  • From the experimental study of W-EDM for alloyed steel, the characteristics such as Hand Drum Form and surface roughness have been observed and evaluated for various conditions. In square hole, the increase of If as to made condition the calculate high value of surface roughness. Also compare dimensionless square hole with circle hole' graph. In circle hole, if a value of surface roughness IP 6 in a side of circle it show a 0.4${\mu}{\textrm}{m}$ and in IP 8, 0.6${\mu}{\textrm}{m}$, in IP 10, 0.7${\mu}{\textrm}{m}$, in IP 12. 0.8${\mu}{\textrm}{m}$ higher than before. This figure show the surface roughness is higher than before, because a table move in either X-axis or Y-axis in square hole, on the contrary, in circle there table move in X-axis and Y-axis at the same time. hand drum form getting small when wire tension increase 1000gf to 1500gf, at the same working conditions. the smaller of off time, the mailer of hand drum form in same condition and same wire tension. but if you compare square hole with circle hole' graph hand drum form displayed in maintained term of working condision, on the contrary, in case of square hole variation of hand drum form is more increase than a grow of IP

  • PDF

PDP 격벽용 금형의 마이크로 홈 연삭 특성 (Characteristics of Micro Groove grinding for the Mold of PDP Barrier Ribs)

  • 조인호;정상철;박준민;정해도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.963-966
    • /
    • 2000
  • Plasma display panel (PDP) is a type of flat panel display utilizing the light emission that is produced by gas discharge. Barrier Ribs of PDP separating each sub-pixel prevents optical and electrical crosstalk from adjacent sub-pixels. Mold for forming barrier ribs has been newly researched to overcome the disadvantages of conventional manufacturing process such as screen printing, sand-blasting and photosensitive glass methods. Mold for PDP barrier ribs have stripes of micro grooves transferring stripes of glass-material wall. In this paper. Stripes of grooves of which width 48 um, depth 124um, pitch 274um was acquired by machining the material of WC with dicing saw blade. Maximum roughness of the bottom and sidewall of the grooves was respectively 120 nm, 287 nm. Maximum tilt angle caused by difference between upper-most width and lower-most width was 2$^{\circ}$. Maximum Radius of curvature of bottom was 7.75 ${\mu}{\textrm}{m}$. This results meets the specification for barrier ribs of 50 inch XGA PDP. Forming the glass paste will be followed by using mold in the near future.

  • PDF

Fabrication of EDM Electrodes by Localized Electrochemical Deposition

  • Habib, Mohammad Ahsan;Gan, Sze Wei;Lim, Han-Seok;Rahman, Mustafizur
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권2호
    • /
    • pp.75-80
    • /
    • 2008
  • The fabrication of complex three-dimensional electrodes for micro electrical discharge machining (micro-EDM) is an important issue in the field of micromachining Localized electrochemical deposition (LECD) is a simple and inexpensive technique for fabricating micro-EDM electrodes. This study presents a new process for manufacturing electrodes with complex cross-sections using masks of different shapes, In this process, a non-conductive mask is placed between an anode and cathode that are immersed in a plating solution of acidified copper sulfate. The LECD is achieved by applying a pulsed voltage between the anode and cathode, which are separated by a small distance. In this setup, the cathode is placed above the anode and the mask, so that the deposited electrode can be used directly for EDM without changing the tool orientation. We found that the microstructure of the deposited electrode is influenced by the concentration of the plating solution and organic additives. Moreover, the values of the voltage, frequency, and duty cycle of the pulsed input have significant effects on the microstructure of the fabricated electrode. Finally, the optimum values of the voltage, frequency, and duty cycle were determined for the most effective fabrication of complex-shaped electrodes.

An Application of Fuzzy Logic with Desirability Functions to Multi-response Optimization in the Taguchi Method

  • Kim Seong-Jun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제5권3호
    • /
    • pp.183-188
    • /
    • 2005
  • Although it is widely used to find an optimum setting of manufacturing process parameters in a variety of engineering fields, the Taguchi method has a difficulty in dealing with multi-response situations in which several response variables should be considered at the same time. For example, electrode wear, surface roughness, and material removal rate are important process response variables in an electrical discharge machining (EDM) process. A simultaneous optimization should be accomplished. Many researches from various disciplines have been conducted for such multi-response optimizations. One of them is a fuzzy logic approach presented by Lin et al. [1]. They showed that two response characteristics are converted into a single performance index based upon fuzzy logic. However, it is pointed out that information regarding relative importance of response variables is not considered in that method. In order to overcome this problem, a desirability function can be adopted, which frequently appears in the statistical literature. In this paper, we propose a novel approach for the multi-response optimization by incorporating fuzzy logic into desirability function. The present method is illustrated by an EDM data of Lin and Lin [2].

자장 여과 아크 이온빔 식각 공정을 이용한 WC-Co 및 SCM415 금속 소재 표면 구조 제어 연구 (Surface Modification of WC-Co and SCM415 by the Ion Bombardment Process of Filtered Vacuum Arc Plasma)

  • 이승훈;윤성환;김도근;권정대;김종국
    • 한국표면공학회지
    • /
    • 제43권2호
    • /
    • pp.80-85
    • /
    • 2010
  • The surfaces of WC-Co and SCM415 were etched to form a micro size protrusion for oil based ultra low friction applications using an ion bombardment process in a filtered vacuum arc plasma. WC-Co species showed that a self-patterned surface was available by the ion bombarding process due to the difference of sputtering yield of WC and Co. And the increasing rate of roughness was 0.6 nm/min at -600 V substrate bias voltage. The increasing rate of roughness of SCM415 species was 1.5 nm/min at -800 V, but the selfpatterning effect as shown in WC-Co was not appeared. When the SCM415 species pretreated by electrical discharge machining is etched, the increasing rate of roughness increased from 1.5 nm/min to 40 nm/min at -800 V substrate bias voltage and the uniform surface treatment was available.

와이어 방전가공을 이용한 상어 표피 모사 리블렛 표면 제작 (Fabrication of a Micro-riblet Shark Skin-like Surface using a WEDM Process)

  • 박영환;김태완
    • Tribology and Lubricants
    • /
    • 제32권6호
    • /
    • pp.201-206
    • /
    • 2016
  • In this study, we attempt to produce a semi-elliptical riblet with a shark skin-like surface using wire electrical discharge machining (WEDM) and micro molding techniques. Our design for the production of the semi-elliptical mold includes an electrode, a winding roller, and a guide on the WEDM system. A replication mold with negative riblets is machined using WEDM, and a shark skin inspired surface with positive riblets is fabricated using a micro molding technique. For a comparison with the original shark skin, a shark skin replica is also produced using the micro molding technique directly from a shark skin template. Droplet contact angles on a flat surface, the shark skin replica, and the epoxy resin-based micro riblet shark skin-like surface are evaluated. The effect of a Teflon coating on the contact angles for the three different surfaces is also investigated. The results show the micro riblet with a shark skin-like surface has a similar contact angle as the shark skin replica, which means that the simplified riblet shark skin surface strongly influences the performance of wettability. This study confirms the effectiveness of using the WEDM method to prepare hydrophobic surfaces with diverse surface patterns.

냉간금형용 합금강의 정밀입자가공에 의한 표면정밀도 향상 (Improvement of Surface Morphology by Precision Particle Process for Cold Die Steel Alloy)

  • 왕덕현;김원일
    • 한국산업융합학회 논문집
    • /
    • 제5권4호
    • /
    • pp.367-372
    • /
    • 2002
  • Experimental study was conducted for lapping process after WEDMed specimen. In order to decide the lapping depth of the specimen, the number of the grain size was increased from 400, 600 to 800 to obtain the better surface. Observation of scanning electron microscope, hardness test, surface roughness test and energy dispersive spectrum(EDS) analysis were used for this experimental study. From the comparison and analyses of the results of between the wire-cut electrical discharge machining and the lapping, the following results were obtained. The surface roughness after lapping was found to be improved as increasing the number of lapping process like 1st, 2nd, 3rd lapping and the number of grain size such as 400, 600, 800. The surface hardness after increasing the lapping depth of the specimen was slowly increased. It was found that after 3rd lapping process the hardness was reached the hardness of original base material. It was found that the small amount of coating components within 3% was remained after the 1st lapping process, compared to that approximately 16% after WEDM process.

  • PDF

A STUDY ON THE RESPONSES OF OSTEOBLASTS TO VARIOUS SURFACE-TREATED TITANIUM

  • Lee Joung-Min;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • 대한치과보철학회지
    • /
    • 제42권3호
    • /
    • pp.307-326
    • /
    • 2004
  • Statement of problem. The long-term success of implants is the development of a stable direct connection between bone and implant surface, which must be structural and functional. To improve a direct implant fixation to the bone, various strategies have been developed focusing on the surface of materials. Among them, altering the surface properties can modify cellular responses such as cell adhesion, cell motility and bone deposition. Purpose. This study was to evaluate the cellular behaviors on the surface-modified titanium by morphological observation, cellular proliferation and differentiation. Material and methods. Specimens were divided into five groups, depending on their surface treatment: electropolishing(EP) anoclizing(AN), machining(MA), blasting with hydroxyapatite particle(RBM) and electrical discharge machining(EDM). Physicochemical properties and microstructures of the specimens were examined and the responses of osteoblast-like cells were investigated. The microtopography of specimens was observed by scanning electron microscopy(SEM). Surface roughness was measured by a three-dimensional roughness measuring system. The microstructure was analyzed by X-ray diffractometer(XRD) and scanning auger electron microscopy(AES). To evaluate cellular responses to modified titanium surfaces, osteoblasts isolated from neonatal rat were cultured. The cellular morphology and total protein amounts of osteoblast-like cell were taken as the marker for cellular proliferation, while the expression of alkaline phosphatase was used as the early differentiation marker for osteoblast. In addition, the type I collagen production was determined to be a reliable indicator of bone matrix synthesis. Results. 1. Each prepared specimen showed specific microtopography at SEM examination. The RBM group had a rough and irregular pattern with reticulated appearance. The EDM-treated surface had evident cracks and was heterogeneous consisting of broad sheet or plate with smooth edges and clusters of small grains, deep pores or craters. 2. Surface roughness values were, from the lowest to the highest, electropolished group, anodized group, machined group, RBM group and EDM group. 3. All groups showed amorphous structures. Especially anodized group was found to have increased surface oxide thickness and EDM group had titaniumcarbide(TiC) structure. 4. Cells on electropolished, anodized and machined surfaces developed flattened cell shape and cells on RBM appeared spherical and EDM showed both. After 14 days, the cells cultured from all groups were formed to be confluent and exhibited multilayer proliferation, often overlapped or stratified. 5. Total protein amounts were formed to be quite similar among all the group at 48 hours. At 14 days, the electropolished group and the anodized group induced more total protein amount than the RBM group(P<.05). 6. There was no significant difference among five groups for alkaline phosphatase(ALP) activity at 48 hours. The AN group showed significantly higher ALP activity than any other groups at 14 days(P<.05). 7. All the groups showed similar collagen synthesis except the EDM group. The amount of collagen on the electropolished and anodized surfaces were higher than that on the EDM surface(P<.05).

하이브리드 Ti2AlC 세라믹 소결체의 재료특성 및 Micro-EDM 유용성 연구 (Micro-EDM Feasibility and Material Properties of Hybrid Ti2AlC Ceramic Bulk Materials)

  • 정국현;김광호;강명창
    • 한국분말재료학회지
    • /
    • 제21권4호
    • /
    • pp.301-306
    • /
    • 2014
  • Titanium alloys are extensively used in high-temperature applications due to their excellent high strength and corrosion resistance properties. However, titanium alloys are problematic because they tend to be extremely difficult-to-cut material. In this paper, the powder synthesis, spark plasma sintering (SPS), bulk material characteristics and machinability test of hybrid $Ti_2AlC$ ceramic bulk materials were systematically examined. The bulk samples mainly consisted of $Ti_2AlC$ materials with density close to theoretical value were synthesized by a SPS method. Random orientation and good crystallization of the $Ti_2AlC$ was observed at $1100^{\circ}C$ for 10 min under SPS sintering conditions. Scanning electron microscopy results indicated a homogeneous distribution and nano-laminated structure of $Ti_2AlC$ MAX phase. The hardness and electrical conductivity of $Ti_2AlC$ were higher than that of Ti 6242 alloy at sintering temperature of $1000^{\circ}C{\sim}1100^{\circ}C$. Consequently, the machinability of the hybrid $Ti_2AlC$ bulk materials is better than that of the Ti 6242 alloy for micro-EDM process of micro-hole shape workpiece.