• Title/Summary/Keyword: Discharge Test

Search Result 1,604, Processing Time 0.027 seconds

Perfluorinated Sulfonic Acid based Composite Membranes for Vanadium Redox Flow Battery (바나듐 레독스 흐름 전지를 위한 과불소화 술폰산 복합막)

  • Cho, Kook-Jin;Park, Jin-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.1
    • /
    • pp.21-27
    • /
    • 2016
  • Vanadium redox flow batteries (VRFBs) using the electrolytes containing various vanadium ions in sulfuric acid as supporting solution are one of the energy storage devices in alternatively charging and discharging operation modes. The positive electrolyte contains $V^{5+}/V^{4+}$ and the negative electrolyte $V^{2+}/V^{3+}$ depending on the operation mode. To prevent the mixing of two solutions, proton exchange membranes are mainly used in VRFBs. Nafion 117 could be the most promising candidate due to the strong oxidative property of $V^{5+}$ ion, but causes high crossover of electroactive species to result in a decrease in coulombic efficiency. In this study, the composite membranes using Nafion ionomer and porous polyethylene substrate were prepared to keep good chemical stability and to decrease the cost of membranes, and were compared to the properties and performance of the commercially available electrolyte membrane, Nafion 117. As a result, the water uptake and ionic conductivity of the composite membranes increased as the thickness of the composite membranes increased, but those of Nafion 117 slightly decreased. The permeability of vanadium ions for the composite membranes significantly decreased compared to that for Nafion 117. In a single cell test for the composite membranes, the voltage efficiency decreased and the coulombic efficiency increased, finally resulting in the similar energy efficiency. In conclusion, the less cost of the composite membranes by decreasing 6.4 wt.% of the amount of perfluorinated sulfonic acid polymer due to the introduction of porous substrate and lower vanadium ion permeability to decrease self-discharge were achieved than Nafion 117.

Preparation and Characterization of a Sn-Anode Fabricated by Organic-Electroplating for Rechargeable Thin-Film Batteries (유기용매 전해조를 이용한 리튬이차박막전지용 Sn 음극의 제조)

  • Kim, Dong-Hun;Doh, Chil-Hoon;Lee, Jeong-Hoon;Lee, Duck-Jun;Ha, Kyeong-Hwa;Jin, Bong-Soo;Kim, Hyun-Soo;Moon, Seong-In;Hwang, Young-Ki
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.4
    • /
    • pp.284-288
    • /
    • 2008
  • Sn-thin film as high capacitive anode for thin film lithium-ion battery was prepared by organic-electrolyte electroplating using Sn(II) acetate. Electrolytic solution including $Li^+$ and $Sn^{2+}$ had 3 reduction peaks at cyclic voltammogram. Current peak at $2.0{\sim}2.5\;V$ region correspond to the electroplating of Sn on Ni substrate. This potential value is lower than 2.91 V vs. $Li^+/Li^{\circ}$, of the standard reduction potential of $Sn^{2+}$ under aqueous media. It is the result of high overpotential caused by high resistive organic electrolytic solution and low $Sn^{2+}$ concentration. Physical and electrochemical properties were evaluated using by XRD, FE-SEM, cyclic voltammogram and galvanostatic charge-discharge test. Crystallinity of electroplated Sn-anode on a Ni substrate could be increased through heat treatment at $150^{\circ}C$ for 2 h. Cyclic voltammogram shows reversible electrochemical reaction of reduction(alloying) and oxidation(de-alloying) at 0.25 V and 0.75 V, respectively. Thickness of Sn-thin film, which was calculated based on electrochemical capacity, was $7.35{\mu}m$. And reversible capacity of this cell was $400{\mu}Ah/cm^2$.

A Case Report of Lumbar HIVD Treated with Korean Medicine on a Polycystic Kidney Patient (다낭신 환자의 요추 추간판탈출증에 대한 통합한방치료 1례)

  • Ju, Ah-ra;Ryu, Gwang-hyun;Park, Mi-so;Choi, Yo-sup;Choo, Won-jung;Chae, Ji-won
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.2
    • /
    • pp.132-140
    • /
    • 2020
  • Objectives: This research study aimed to determine the effect of Korean medicine treatments on a patient with lumbar disc herniation accompanying polycystic kidney disease. Methods: Acupuncture, herbal medicine, pharmacopuncture, spine decompression therapy, Motion Style Acupuncture Treatment (MSAT), and Chuna were preceded for treatment. We checked the patient's Oswestry Disability Index (ODI), numeric rating scale (NRS), and straight leg raise test (SLRT) on admission and discharge; we also used the NRS and SLRT to evaluate the patient's symptoms on every third day during the hospital stay. Because it is important to manage blood urea nitrogen (BUN), serum creatinine, and blood pressure during the early stage of polycystic kidney disease, BUN and serum creatinine levels were checked weekly while blood pressure was checked every morning. Results: Twelve days after admission, the NRS for lower back pain and right leg pain decreased from 7 to 3 and from 7 to 2, respectively. The ODI value also decreased from 56 to 20 while the SLRT value increased from 30/70 to 60/70. The BUN and serum creatinine levels and the blood pressure readings were all within normal range every time they were checked. Conclusions: The use of Korean medicine treatments resulted in improvements in NRS, ODI, and SLRT on a patient with a herniated lumbar disc herniated who had a past history of polycystic kidney disease; thus, the patient was able to maintaining kidney functioning. Herbal medicine, an alternative method of analgesic anti-inflammatory drugs that has been evaluated as relatively safe on liver and kidney function, could be suggested on a patient with a past history of polycystic kidney disease to maintain kidney function when renal function and blood pressure are monitored.

Pre-operative Predictive Factors for Intra-operative Pathological Lymph Node Metastasis in Rectal Cancers

  • Gao, Chun;Li, Jing-Tao;Fang, Long;Wen, Si-Wei;Zhang, Lei;Zhao, Hong-Chuan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6293-6299
    • /
    • 2013
  • Background: A number of clinicopathologic factors have been found to be associated with pathological lymph node metastasis (pLNM) in rectal cancer; however, most of them can only be identified by expensive high resolution imaging or obtained after surgical treatment. Just like the Child-Turcotte-Pugh (CTP) and the model for end-stage liver disease (MELD) scores which have been widely used in clinical practice, our study was designed to assess the pre-operative factors which could be obtained easily to predict intra-operative pLNM in rectal cancer. Methods: A cohort of 469 patients who were treated at our hospital in the period from January 2003 to June 2011, and with a pathologically hospital discharge diagnosis of rectal cancer, were included. Clinical, laboratory and pathologic parameters were analyzed. A multivariate unconditional logistic regression model, areas under the curve (AUC), the Kaplan-Meier method (log-rank test) and the Cox regression model were used. Results: Of the 469 patients, 231 were diagnosed with pLNM (49.3%). Four variables were associated with pLNM by multivariate logistic analysis, age<60 yr (OR=1.819; 95% CI, 1.231-2.687; P=0.003), presence of abdominal pain or discomfort (OR=1.637; 95% CI, 1.052-2.547; P=0.029), absence of allergic history (OR=1.879; 95% CI, 1.041-3.392; P=0.036), and direct $bilirubin{\geq}2.60{\mu}mol/L$ (OR=1.540; 95% CI, 1.054-2.250; P=0.026). The combination of all 4 variables had the highest sensitivity (98.7%) for diagnostic performance. In addition, age<60 yr and direct $bilirubin{\geq}2.60{\mu}mol/L$ were found to be associated with prognosis. Conclusion: Age, abdominal pain or discomfort, allergic history and direct bilirubin were associated with pLNM, which may be helpful for preoperative selection.

A Study on Changes in Indoor Air Pollution by Educational Activities -Centering on Newly-Established Elementary Schools- (교육활동에 따른 실내오염도 변화에 관한 연구 -신설 초등학교를 중심으로-)

  • Jeon, Seok-Jin
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.6 no.2
    • /
    • pp.66-90
    • /
    • 2007
  • The purpose of this study is to measure and analyze primary causes of indoor air pollution, including carbon dioxide, minute dust, and total volatile organic compounds, for each room before the beginning of a class through the time of discharge after the end of the class in general classrooms, computer rooms, and science rooms of three newly-established schools that opened in 2006, examine properties of indoor air environment in each room by educational activities at school, and determine effective management schemes; the results of this study can be summarized as follows: 1) As for implications for each item found in the mean for each place, since minute dust (PM10) was more likely to occur in time slots full of students' activities, such as a traveling class and a recess, than in the middle of a class and could be expected fully, it is necessary to make a scheme for cleaning in order to reduce minute dust within a room, for example, by usually using a vacuum cleaner indoors. 2) While carbon dioxide was expected to vary with the differences in the amount of breath between higher-graders and lower-graders in a general classroom but showed insignificant difference by grades, showing differences in pollution by four times at a maximum according to the opening of a window as expected, it is necessary to implement artificial or natural ventilation and take a positive measure, for example, by presenting a concrete ventilation scheme, in order to improve indoor air pollution at a room practice. 3) Total volatile organic compounds were found to exceed the standard by more than twice in general classrooms, science rooms, and computer rooms of the schools because of building materials, furnitures including desks and chairs, panels and boards for environment beautification, and items which could be detected even from students' clothes; while a field directly-reading tool was used, obtaining high reliability for the results, it is necessary to apply an analytical method based on process test separately for actual correct measurement if a significantly great amount of total volatile organic compounds appear as compared with other schools due to measuring expenses and consecutive measurements. 4) Since formaldehyde (HCHO) was generally found to exceed the standard in general classrooms, science rooms, and computer rooms, it is necessary to establish and operate a ventilator during a class in a computer room which requires airtightness and a science room in which an organic compound should be used for a class.

  • PDF

Lifetime test of batteries for BLE modules for site identification of vessel's crews and passengers (SIVCP) (SIVCP용 BLE 모듈의 배터리 수명시험)

  • Kwon, Hyuk-joo;Kim, Min-Gwon;Kim, Yoon-Sik;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.754-759
    • /
    • 2015
  • Nowadays, short distance communication systems with low power energy (LPE) are developed for identification and monitoring of site identification of vessel crews and passengers (SIVCP). LPE communication modules, such as Bluetooth low energy (BLE) and Zigbee, are used for short distance communications with LPE. These modules enable 1:N communications and their popularity is growing since the modules can be mounted on movable objects, such as mobile devices and human body. When these modules are used, the important factor that affects their operation time and design are the capacity and size of battery. Therefore, they must be made as small as possible, and the battery should be selected to be slightly smaller than the module. In this study, we calculate the theoretical life of batteries used in SIVCP BLE modules using data sheet and discharge characteristic graph under the condition of a 1/250 transmission-ratio (TR). We thus calculate experimental life by measuring transmission current for the same TR, and low speed mode current for a 1/5000 TR and measure long-term experimental life using 1/25 TR for days. Through these experiments, we verify experimental methods for the prediction and extension of battery life that would enable us to select appropriate sizes of batteries based on vessel usage and passenger types. The selections of the module TR and battery size are important factors affecting the cost reduction of module design, the battery maintenance, and passenger convenience.

The Homecare Needs of Cancer Patients (암환자의 퇴원 후 가정간호 요구)

  • Kwon, In-Soo;Eun, Young
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.4
    • /
    • pp.743-754
    • /
    • 1999
  • The purpose of this descriptive study was to identify the homecare needs of patients with cancer and to provide a basis of interventions. One hundred and two patients at one general hospital in Gyeongnam responded to a questionnaire developed on the basis of care needs perceived by nurses caring for hospitalized patients with cancer. The questionnaire was a Likert type 5 point scale with 56 items on five need categories ; 1) informational 2) physical care : 3) emotional care 4) socioeconomic care and 5) special care needs. Internal consistency of this questionnaire was Cronbach's $\alpha$=.9101 for total items. The data was collected from March 1st to May 31th, 1998, by two graduate nurses. In the data analysis, mean & standard deviation were calculated to identify the degree of care need of each item, and the t-test & ANOVA were done to determine the effects of patients' demographic background on their care needs. The findings are summarized as follows ; 1) The mean score of total of need items was 3.048. Of the four need categories the highest score was informational at 3.4, followed by emotional care, 3.063, physical care, 2.623, and socioeconomic care, 2.599. 2) In the informational need category there were four subcategories with 19 items. Medication and pain control had the highest score, 3.755 ; second was diet and exercise, 3.613 ; third was disease and treatment process, 3.337 ; and last was personal hygiene and infection prevention at 2.687. 3) In the physical care need category there was nine items, IV infusion for nutrition and management of treatment complication was above 3.2 points and the remaining items were in the 2.847-2.070 score ranges. 4) In the emotional care need category there were seven items. The highest need was in support for relationships with health personnel, 3.673. The need for support of religions beliefs and support for having a religion were low at about 2 points. 5) In the socioeconomic care need category there were six items. Support for medical insurance expansion and financial support were above 3 points. Legal support and support for caring of children were low in the care needs. 6) In the special care need category the there were 15 items. Informational need about immunization and informational need about effects of disease on growth and development were high, above 4.1 points. Need for decubitus care and prevention, sitz bath and incontinence care were low, below 2 points. 7) There were significant differences in degree of care need according to admission rate, education level, marital status, religion and caregiver's religion. In conclusion, homecare needs perceived by hospitalized patient's with cancer was moderate, but informational need was higher than direct care need, leading to the conclusion that the provision of sufficient information to patients with cancer at discharge is needed. Nursing interventions should be developed considering the patient's background.

  • PDF

Infusion Methods for Continuous Interscalene Brachial Plexus Block for Postoperative Pain Control after Arthroscopic Rotator Cuff Repair

  • Byeon, Gyeong Jo;Shin, Sang Wook;Yoon, Ji Uk;Kim, Eun Jung;Baek, Seung Hoon;Ri, Hyun Su
    • The Korean Journal of Pain
    • /
    • v.28 no.3
    • /
    • pp.210-216
    • /
    • 2015
  • Background: Infusion methods during regional analgesia using perineural catheters may influence the quality of postoperative analgesia. This study was conducted to compare the effects of combined or bolus-only infusion of 0.2% ropivacaine on the postoperative analgesia in interscalene brachial plexus block (ISBPB) with perineural catheterization. Methods: Patients scheduled for arthroscopic rotator cuff repair were divided into two groups, one that would receive a combined infusion (group C, n = 32), and one that would receive intermittent infusion (group I, n = 32). A perineural catheter was inserted into the interscalene brachial plexus (ISBP) using ultrasound (US) and nerve stimulation, and 10 ml of 0.2% ropivacaine was administered. After the operation, group C received a continuous infusion of 4 ml/h, and a 4 ml bolus with a lockout interval of 60 min. Group I received only a 4 ml bolus, and the lockout interval was 30 min. Postoperative pain by the numeric rating scale (NRS) and the forearm muscle tone by the manual muscle test (MMT) were checked and evaluated at the following timepoints: preoperative, and postoperative 1, 4, 12, 24, 36, and 48 h. Supplemental opioid requirements, total consumed dose of local anesthetic, and adverse effects were compared between the two groups. Results: Sixty-four patients completed the study and the postoperative values such as operation time, time to discharge, and operation site were comparable. There were no differences in NRS scores and supplemental opioid requirements between the two groups. The MMT scores of group I at 4 and 12 h after surgery were significantly higher than those of group C (P < 0.05). The total consumed dose of local anesthetic was significantly lower in group I than in group C (P < 0.05). The adverse effects were not different between the groups. Conclusions: The bolus-only administration of 0.2% ropivacaine provided a similar analgesic effect with a lower total volume of local anesthetic and decreased motor weakness compared to combined infusion. Therefore, bolus-only administration is an effective postoperative analgesic method in ISBPB with perineural catheterization after rotator cuff repair.

A Study on Groundwater Flow Modeling in the Fluvial Aquifer Adjacent to the Nakdong River, Book-Myeon Area, Changwon City (창원시 북면 낙동강 주변 하성퇴적층의 지하수유동 모델링 연구)

  • Hamm Se-Yeong;Cheong Jae-Yeol;Kim Hyoung-Su;Hahn Jeong-Sang;Ryu Su-Hee
    • Economic and Environmental Geology
    • /
    • v.37 no.5
    • /
    • pp.499-508
    • /
    • 2004
  • Changwon City first constructed riverbank filtration plants in Book-Myeon and Daesan-Myeon in Korea in the year 2001. This study evaluated hydrogeological characteristics and groundwater flow simulation between the Nakdong River and the fluvial aquifers adjacent to the river in Book-Myeon, Changwon City. The groundwater simulation calculated the influx rate from the Nakdong River and the fluvial aquifers to pumping wells through the riverbank filtration system. The groundwater flow model utilized drilling, grain size analysis, pumping test, groundwater level measurements, river water discharge and rainfall data. Hydraulic heads calculated by the steady-state model closely matched measured heads in pumping and observation wells. According to the transient flow model, using a total pumping amount of 14,000 $m^3$/day, the flux into the pumping wells from the Nakdong River accounts for 8,390 $m^3$/day (60%), 590 $m^3$/day (4%) is from the aquifer in the rectilinea. direction to the Nakdong River, and 5,020 $m^3$/day (36%) is from the aquifer in the parallel direction to the Nakdong River. The particle tracking analysis shows that a particle from the Nakdong River moves toward the pumping wells at a rate of about 1.85 m/day and a particle from the aquifer moves toward the pumping wells at a rate of about 0.75 m/day. This study contributes to surface water/groundwater management modeling, and helps in understanding, how seasonal change affects pumping rates, water quality, and natural recharge.

Development of a Vegetation Buffer Strip Module for a Distributed Watershed Model CAMEL (유역모델 CAMEL 기반 식생여과대 모듈의 개발)

  • Park, Min-Hye;Cho, Hong-Lae;Koo, Bhon-Kyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.5
    • /
    • pp.516-531
    • /
    • 2015
  • In this study, a software module to predict the effectiveness of vegetation buffer strip (VBS) has been developed for using with Chemicals, Agricultural Management and Erosion Losses (CAMEL), a distributed watershed model. Most basic functions for the VBS module are same as CAMEL except functions newly developed to implement sedimentation enhancement by vegetation and level spreaders. For verification of the VBS module, sensitivity analyses for length, roughness, soil and vegetation type of VBS were carried out using a test grid cell. The surface discharge of sediment are highly sensitive to the roughness coefficient of VBS. The removal efficiencies of VBS for the surface discharges of sediment and TP are generally high regardless of environment changes. The surface discharges of TOC and TN are highly sensitive to the length and soil of VBS. The removal efficiencies of VBS for the surface discharges of TOC and TN are generally lower than those of sediment and TP. The newly developed VBS module reasonably simulates the removal efficiencies of surface discharges that vary according to the environment changes. It is expected that this VBS module can be used for evaluating the effectiveness of VBS-based best management practices to be applied to reduce pollution discharges from various non-point sources.