• Title/Summary/Keyword: Discharge Mode

Search Result 292, Processing Time 0.031 seconds

A Real-Time Diagnostic Study of MgO Thin Film Deposition Process by ICP Magnetron Sputtering Method (MgO 증착을 위한 유도결합 플라즈마 마그네트론 스퍼터링에서 실시간 공정 진단)

  • Joo Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.2
    • /
    • pp.73-78
    • /
    • 2005
  • A real-time monitoring of ICP(inductively coupled plasma) assisted magnetron sputtering of MgO was carried out using a QMS(quadrupole mass spectrometer), an OES(optical emission spectrometer), and a digital oscilloscope with a high voltage probe and a current monitor. At the time of ICP ignition, the most distinct impurity was OH emission (308.9 nm) which was dissociated from water molecules. For reactive deposition oxygen was added to Ar and the OH emission intensity was reduced abruptly When the discharge voltage was regulated by a PID controller from 240V(metallic mode) to 120V(oxide mode), the emission intensity from Mg (285.2 nm) changed proportionally to the discharge voltage, but the intensity of Ar I(811.6 nm) was constant. At 100V of discharge voltage, Mg sputtering was almost stopped. Emissions from Ar I(420.1 nm) and Mg I were dropped down to 1/10, but Ar I(811.6 nm) didn't change. And the emission from atomic oxygen (O I, 777.3 nm) was increased to 10 times. These results are compatible with those from QMS study.

An Experimental Study on Performance Improvement of Automotive Air Handling System (자동차용 공기분배장치의 성능개선에 관한 실험적 연구)

  • Yoo, Seong-Yeon;Lee, Dae-Woong;Kim, Jin-Hyuck
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.622-629
    • /
    • 2007
  • Compact semi-center type automotive air handling system(AHS) is developed in this study and it's performance is compared with the conventional 3-pieces type air hand-ling system. The pressure drop is measured at component level and system level, and air flow rate and air distribution of discharge air through each ducts from air handling system are measured. System level characteristics of pressure drop at face and windshield discharge mode and air flow rate are investigated, and also temperature control linearities are tested. The volume of the air handling system package is reduced about 20%. And air flow rate increase about 5 to 20% compared to the conventional 3-pieces type air handling system at each discharge mode with significantly improved air pressure drop both component and system level. Also, air distribution and temperature controllability meet to evaluation criteria.

A New Driving Method for Gray-scale Expression in an AC Plasma Display Panel (교류형 플라즈마 디스플레이 패널에서 계조표현을 위한 새로운 구동방식)

  • 김재성;황현태;서정현;이석현
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.8
    • /
    • pp.407-414
    • /
    • 2004
  • In this paper, a new gray scale expression method that divides the scan lines into multiple blocks is suggested. The proposed method can drive 16 sub-fields per 1 TV field in the panel with XGA ($1366{\times}768$) resolution. The on and off states of even subfields depend on the condition of odd subfields. The write address mode is used in the odd subfields, while the erase address mode is used in the even subfields. Because the ramp reset pulse is applied every 2 sub-fields, both the contrast ratio and the dynamic voltage margin are sufficiently obtained in comparison with previous AWD (Address While Display) methods. In realizing 16 subfields, shortening the scan time in the erase address period was important. The X bias voltage in the erase address period affected the minimum address voltage but did not the delay time of the address discharge. The delay time of the address discharge was affected by the address voltage and the time interval between the last sustain discharge and the scanning time. We also evaluated the dynamic false contour. New method shows an improved image quality in horizontal moving, but discontinuous lines were observed at the boundaries of each block in vertical moving

On-line PD Monitoring Using UHF Technique (UHF 가술을 이용한 온라인 PD 모니터링)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.115-118
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers. is designed, which has been installed inside the oil tank of a transformer by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

Sustain Discharge Mode Assisted by Various Auxiliary Pulses in AC PDP

  • Cho, Byung-Gwon;Tae, Heung-Sik;Chien, Sung-Ii
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.113-116
    • /
    • 2003
  • The sustain discharge mode using various auxiliary pulses was proposed to improve both the luminance and luminous efficiency of ac-plasma display panel (ac-PDP). It was found that the various auxiliary pulses, which were applied at the rising and falling time of the sustain pulse, played a role in strengthening both the main and self-erasing discharges. As a result, the sustain waveforms with auxiliary pulse improved both the luminance of 23 % and the luminous efficiency of 36 %, when compared with the conventional sustain waveform without auxiliary pulse.

  • PDF

On-line Insulation Diagnostic by PD Monitoring Field Practical of UHF Technique for On-line PD Monitoring (UHF 기술을 이용한 온라인 부분방전 모니터링)

  • Oh, Yong;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.176-180
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of transformer in a substation by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

The Characteristics of Tracking Phenomena and Surface Discharge Using Various Types of Electrode Arrangement in $LN_{2}$ at the Atmospheric Pressure (대기압하의 액체질소중 전극배치에 따른 고체유전체 표면의 연면방전 및 Tracking현상)

  • 박경태;신호영;박광서;최병주;이광식;이동인
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.114-118
    • /
    • 2002
  • This paper were investigated discharge characteristics in the Liquid Nitrogen($LN_{2}$) noticed as a cooling medium of high temperature superconductor, and the characteristics of surface discharge and tracking phenomena on the solid insulators of cryocable. In order to investigate the bubbles which have much influence on electric surface discharge in Liquid Nitrogen, knife type electrode and plane electrode was formed oppositely with mode A and B, C configuration. It is considered that these result are fundamental data for electric insulation design of superconductivity and cryogenic application machinery which will be studied and developed in the future.

  • PDF

Development of discharge lamp ballast for wave improvement (파형개선을 위한 방전등 안정기 개발)

  • Lee, O.K.;Song, D.S.;Kim, T.W.;Lee, J.T.;Song, H.S.;Kim, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.85-88
    • /
    • 2000
  • This paper was development a discharge lamp ballast in order to wave improvement of high power factor and high efficiency. The discharge lamp ballast consists of a power factor correction circuit and a correction circuit on switching frequency of inverter. Instead of passive power factor circuit, active power factor circuit is adopted. Because it has the advantage of size, weight, total harmonic distortion, out DC voltage regulation, and power factor. The power factor circuit with MG34262 is controlled by variable frequency discontinuous mode. Results experiments, discharge lamp ballast is showed to have excellent for the proposed electronic ballast's operation and characteristics.

  • PDF

Characteristics of Laser-Guided DC Discharge for Modes by Infrared Laser (모드 변화에 따른 적외선 레이저에 의한 방전 유도 특성)

  • Lee, D.H.;Nahm, G.H.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1905-1907
    • /
    • 1997
  • The experiments of laser-guided de discharge were carried out by using pulsed Nd:YAG laser radiation at low air pressure ranging from 0.3 to 20 torr. The minimum laser-guided de discharge voltages($V_{MD}$) at given pressure and distances between anode and cathode electrode were obtained. In order to generate TEM(transverse electromagnetic waves) modes, a pinhole was installed between a rod and a half mirror, and its diameter was adjusted from 6mm to 1.7mm. And then, we investigated the characteristics of laser-guided de discharge corresponding to different TEM modes. As a result, it was found that $V_{MD}$ at $TEM_{00}$ mode was lower than $V_{MD}$ at multimodes.

  • PDF

An Analysis of the Characteristics of Pseudo-Spark Discharge (Pseudo-Spark 방전 특실의 해석(1))

  • Shim, Jae-Hak;Chang, Yong-Moo;Ko, Kwang-Cheol;Kang, Hyung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1533-1535
    • /
    • 1994
  • The Monte-Carlo simulation was used to define the physical mechanisms of the initiation phase of pseudo-spark discharge. The pseudo-spark discharge employing the hollow cathode geometry is accompanied by very fast current rising and intense charged particle beams. In this model, time-dependent continuity equation for the electrons and ions were solved consistently with Poisson's equation for the electric field in a two-dimensional, sysmmetrically cylinderical geometry. From the simulation, a sequence of physical mechanisms that cause the rapid current rise associated with the onset of pseudo-spark discharge mode were identified.

  • PDF