• Title/Summary/Keyword: Discharge Delay

Search Result 124, Processing Time 0.026 seconds

A Study on Change of Suspended Solids by Forest Road Construction(I) -Parallel Watersheds Method- (임도개설(林道開設)에 따른 부유토사량(浮遊土砂量) 변화(變化)(I) -대조유역법(對照流域法)을 중심(中心)으로-)

  • Kim, Kyoung-Jin;Chun, Kun-Woo
    • Journal of Forest and Environmental Science
    • /
    • v.10 no.1
    • /
    • pp.57-65
    • /
    • 1994
  • This study was carried out to clarify the sediment export by measuring suspended solids included in streamflow during the rainy season. The study area is located in Experimental Forests, Kangwon National University, where the forest road is under construction. For this purpose, the forest watershed with construction of forest road was compared with normal forest watershed in amount of rainfall and discharge, suspended solids and discharge, and the amount of rainfall and suspended solids. The results were shown as followings. 1. The relationship of discharge and the amount of rainfall was shown as Table 3 and Fig. 3. The delay time of peak point observed in hydrograph was changed by rainfall intensity and amount of previous rainfall. That is, when there was a rain on 12. Jun(more than 20mm/hour for hours), the peak point began three hours after the rainfall intensity over 20mm/hour, and showed $1514m^3/hour$ in automatic water level recorder. In case of the 8th of Aug.(maximum rainfall intensity: 40mm/hour), the peak point of discharge was $1246m^3/hour$ in the same time with maximum rainfall intensity. And on the 20th of Aug.(the maximum rainfall intensity: 17.2mm/hour), the peak point of discharge was $1245m^3/hour$ two hours after the maximum rainfall intensity. 2. On watershed under forest road construction, the relationship between discharge and suspended solids is that suspended solids was proportionately increased by raising discharge. That is, on the 12th of Jun, the maximum of discharge per hour was $1514m^3/hour$ and 1261mg/l of suspended solids was observed an hour after peak point of discharge. And in case of 8th and 20th Aug., each of peak points is $1246m^3/hour$ and $1245m^3/hour$ by measuring time. The maximums of suspended solids measured within two watersheds were examined in value of 4952mg/l and 472mg/l at the same time. 3. During the rainy season, the concentration of suspended solids was influenced by rainfall intensity and indicated especially curve-regressional increase in case of strong rainfall intensity. In each of watersheds, the maximums of suspended solids were 1261mg/l and 125mg/l, 4952mg/l and 44mg/l, and 472mg/l and 4mg/l by the order of rain(a), (b), and (c). Two watersheds showed a remarkable difference.

  • PDF

Improvement of Luminous Efficacy of Plasma Display Panel with Double Pulse Memory (Double Pulse Memory 방식을 이용한 Plasma Display Panel의 효율 향상에 관한 연구)

  • Choi, Kyung-Cheol;Shin, Bum-Jae;Whang, Ki-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.423-426
    • /
    • 1991
  • A Plasma Display Panel with Double Pulse Memory was fabricated and its luminance and luminous efficacy were investigated. Application of non-discharge pulses to an auxiliary anode increased luminance by 43% and luminous efficacy by 33%. Compared to PDP with PPM(Planar Pulse Memory) driving technique, PDP with DPM obtained higher luminous efficacy and consumed lower power with the same delay time.

  • PDF

Surgical Treatment of Femoral & Popliteal Arteries Thrombosis Caused by Collagen Material Closure Device - A case report - (콜라겐제제 봉합제 사용으로 인한 우측 대퇴동맥, 우측 슬와동맥 혈전증의 수술적 치료)

  • Jo, Tae-Jun;Chee,, Hyun-Keun
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.396-399
    • /
    • 2005
  • Manual or mechanical compression followed by 4 to 8 hours of bed rest is still the standard technique for accessing site management of the femoral arterial puncture site. But these methods are often uncomfortable and delay hospital discharge. Recently, a number of new devices to achieve hemostasis have been developed. These devices uses collagen to facilitate local hemostasis. But many complications associated with the use these devices have been reported internationally. We present a case of successful treatment of Rt. femoral and Rt. popliteal arteries thrombosis caused by Angioseal.

Influence of gas mixing ratio on Xe spectrum for improving Luminous Efficiency & High Speed discharge images in AC-PDP

  • 안정철
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.233-233
    • /
    • 1999
  • 본 연구에서는 2성분계 gas(Ne+Xe)를 사용하여 기체압력(p), 진동수(f)에 따라 VUV(Vacuum Ultra Violet) spectrum 147, 173nm 파장과 IR(Infrared) spectrum 823nm, 828nm을 Vacuum Monochromator(Acton-VM 507)를 통해 측정하였다. 휘도(Luminance)와 전력(Power)측면에서 Ne+ Xe 최적의 가스 조성비를 찾기 위해서 Xe의 혼합비에 따른 IR영역인 823nm, 828nm을 측정결과, Xe 4%일 때 좋은 효율을 나타냈다. 기체압력이 200Torr에서는 Xe(3P1)에 기인하는 147nm가 주요한 파장이며, 기체압력이 400Torr, 600Torr일때는 Xe(3P2)에 기인하는 173nm 파장이 주요함을 알 수 있었다. 또한 공간 방전 이미지를 전압 pulse 인가후 ICCD Camera(V-Tek)의 Ready time, On Time을 조절하면서 50ns delay로 관측하였다. 향후 실험계획은 실제 상용화되고 있는 혼합가스 He+Ne+Xe의 조성비에 따른 자세한 실험을 할 것이다.

  • PDF

A Study on Mixture Composition and Combustion Characteristics in Gasoline Engine (가솔린 기관의 혼합기 조성과 연소 특성에 관한 연구)

  • Kim, Gi-Bok;Yoon, Chang-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.18 no.4
    • /
    • pp.197-206
    • /
    • 2015
  • Recently the automobile engine has been developed in achieving the high performance, fuel economy, and emission reduction. In a conventional spark ignition engine the fuel and air are mixed together in the intake system, inducted through the intake valve into the cylinder, and then compressed. Under normal operating conditions, the combustion is initiated towards the end of the compression stroke at the spark plug by an electric discharge. Following inflammation, a flame develops and propagates through this premixed fuel-air mixture. Therefore the state of mixture is very important in the combustion and emission characteristics. In this study the combustion and emission characteristics were tested and analyzed with changing the mixture composition and engine operating parameters in order to improve the combustion and performance in engine.

A Sensitivity Measurement of Ultrasonic Signals by PZT Sensor (PZT 센서를 이용한 초음파 신호 감도측정)

  • 최인혁;권동진;윤장완;정길조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.403-405
    • /
    • 1999
  • Power transformers have a tendency of ultra-high voltage and huge capacity as power demand increases day after day. Therefore, the fault by insulation destruction gives rise to large area of power failure in huge capacity transformers. On-line predictive diagnostics is very important In power transformers because of economic loss and its spreading effect. Hence, this study presents experiments of partial discharge method using ultrasonic sensor in order to confirm the possibility of ultrasonic sensor in power transformers. It carries out the experiments of measuring delay time between ultrasonic sensor and transducer, sensitiities by temperature change of oil and by barriers inside transformers. It is also Included wave analysis by ultrasonic sensor for needle-plate electrode powered on through high-voltage equipments.

  • PDF

A Study of Negative Waveform in ac PDP during Reset and Address Periods (ac PDP에서의 Reset과 Address 구간에서 Negative Waveform특성에 관한 연구)

  • Eom, Cheol-Hwan;Kang, Jung-Won
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.1
    • /
    • pp.27-31
    • /
    • 2009
  • A characteristic of new waveform, called a negative waveform, was studied during reset and address periods. IR distribution, black luminance and time delay were measured to compare the negative waveform with the conventional positive waveform. Based on the analysis of IR measurement, the negative waveform could accumulate more wall charges than the positive waveform. Also the black luminance of negative waveform was lower than that of positive waveform under the same bias and ramp-slope conditions. During address period, the discharge time lag was measured. The negative waveform was showed 0.25 us faster formative time lag and 0.1 us faster average time lag than those of positive waveform.

  • PDF

Design and Test of Vacuum Rotary Arc Gap Switch (Vacuum Rotary Arc Gap Switch의 설계 및 시험)

  • 서길수;황동원;이태호;황리호;김희진;이홍식;임근희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • Design and test results of a VRAG(Vacuum Rotary Arc Gap) switch were presented. To control the damage of electrodes caused by the vacuum arc, Lorentz's force by the radial magnetic field between spiral electrodes was used to rotate the vacuum uc. VRAG switch electrodes were made of the material of CuCr and OFHC. Gap distance between two spiral type electrodes for the rotation of the arc discharge is 8, 10, 12mm. In the cathode, one trigger electrode was inserted into each spiral wing. Normal operation of the VRAG switch was confirmed with 10.6[$mutextrm{s}$]of trigger delay and 2~3[$mutextrm{s}$] of the jitter time. The speed of the vacuum arc was measured to be 0.6 ~ 1[km/s] by a motion analyzer.

A Study on the Delay-Time of DC Discharge in the Plasma Display Panel (플라즈마 디스플레이 패널의 직류방전 지연시간에 관한 연구)

  • Ryeom, Jeong-Duk;Kwak, Hee-Ro
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.200-204
    • /
    • 2006
  • 본 연구에서는 새로 고안된 NOT-AND 논리에 의한 방전 논리 gate PDP의 입력 DC 방전특성에 대해 고찰하고 동작특성을 해석하였다. 새로 고안된 방전 AND gate는 방전 경로에 따른 전극사이의 전위차의 변화로 AND 출력을 유도한다. 이러한 방전 논리 소자를 가지는 PDP에서는 직류방전이 논리게이트의 역할을 한다. 실험결과 이 DC 입력방전을 위해 priming 방전을 인가한 경우가 인가하지 않은 경우에 비해 방전지연시간이 1/3로 단축되며 방전개시전압은 1/2로 감소하였다. 또한 이 priming 방전은 방전종료후 $30{\mu}s$ 정도까지 영향을 미친다. 그리고 이 직류방전의 시간적, 위치적 방전특성을 측정한 결과, 방전에 따른 시간적 거리의 변화는 상당한 영향을 미치나 인접 전극들의 위치적인 영향은 거의 미미하다는 결론을 얻었다.

  • PDF

A Pilot Test of Various Vertical Drains and its Initial Monitoring Results (다양한 연직배수재의 시험시공 및 초기현장 계측)

  • Kim, Ju-Hyong;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.2
    • /
    • pp.45-50
    • /
    • 2006
  • Although the discharge capacity of the natural fiber drains are very low compared to that of plastic drain board (PDB), it is found that the conventional fiber drains and the new developed straw drain boards have great potential for use as a substitute for conventional plastic drain boards through several model tests. To verify their field application, a pilot test using environmentally friendly drains is also being carried out to prove their effective discharge capacity in the field. The pilot test site was divided into 5 different areas, with various combinations of vertical and horizontal drains installed for evaluation. Definite characteristics of various drains are still to be found due to the delay in construction of embankment. Consolidation behavior of three types of vertical drains and two types of horizontal drains will be analyzed after the completion of the embankment in the near future.

  • PDF