• 제목/요약/키워드: Disc Spring

검색결과 57건 처리시간 0.046초

Seismic response analysis of RC frame core-tube building with self-centering braces

  • Xu, Long-He;Xiao, Shui-Jing;Lu, Xiao
    • Structural Monitoring and Maintenance
    • /
    • 제5권2호
    • /
    • pp.189-204
    • /
    • 2018
  • This paper examines the seismic responses of a reinforced concrete (RC) frame core-tube building with pre-pressed spring self-centering energy dissipation (PS-SCED) braces. The PS-SCED brace system consists of friction devices for energy dissipation, pre-pressed combination disc springs for self-centering and tube members as guiding elements. A constitutive model of self-centering flag-shaped hysteresis for PS-SCED brace is developed to better simulate the seismic responses of the RC frame core-tube building with PS-SCED braces, which is also verified by the tests of two braces under low cyclic reversed loading. Results indicate that the self-centering and energy dissipation capabilities are well predicted by the proposed constitutive model of the PS-SCED brace. The structure with PS-SCED braces presents similar peak story drift ratio, smaller peak acceleration, smaller base shear force and much smaller residual deformations as compared to the RC frame core-tube building with bucking-restrained braces (BRBs).

자동차용(自動車用) 충격흡수기(衝擊吸收器)의 해석(解析) 및 품질향상(品質向上)을 위(爲)한 설계방안(設計方案) (Analysis shockabsorber of automobile and Design Criterion)

  • 김형섭;이화석;오흥국
    • 한국안전학회지
    • /
    • 제2권1호
    • /
    • pp.59-71
    • /
    • 1987
  • A study has been made of the damping force phenomena of the shockabsorber for automobile. The main results obtained are as follows; 1) We can neglect friction loss between cylinder and piston, as it is very small compared to other damping force. 2) Damping force due to coil spring and disc valve shows comparatively stable at various piston speed and oil temperature. 3) Theoretical and experimental values are well agreed on relatively low piston speed. 4) Theoretical value on piston speed of 600mm/sec, 900mm/sec at oil temperature $20^{\circ}C$, $40^{\circ}C$, $60^{\circ}C$ and $80^{\circ}C$ is about 82% of experimental value. 5) Theretical value at oil temperature $-20^{\circ}C$, $0^{\circ}C$ is about 67% of experimental value.

  • PDF

Crack identification in short shafts using wavelet-based element and neural networks

  • Xiang, Jiawei;Chen, Xuefeng;Yang, Lianfa
    • Structural Engineering and Mechanics
    • /
    • 제33권5호
    • /
    • pp.543-560
    • /
    • 2009
  • The rotating Rayleigh-Timoshenko beam element based on B-spline wavelet on the interval (BSWI) is constructed to discrete short shaft and stiffness disc. The crack is represented by non-dimensional linear spring using linear fracture mechanics theory. The wavelet-based finite element model of rotor system is constructed to solve the first three natural frequencies functions of normalized crack location and depth. The normalized crack location, normalized crack depth and the first three natural frequencies are then employed as the training samples to achieve the neural networks for crack diagnosis. Measured natural frequencies are served as inputs of the trained neural networks and the normalized crack location and depth can be identified. The experimental results of fatigue crack in short shaft is also given.

구조해석을 통한 척추측만증 교정 분석에 필요한 모델 개발 (Development of a Mathematical Model for Effect of Scoliosis Surgical Correction)

  • 김영은;최형연;손창규;이광희;이춘기
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.1059-1061
    • /
    • 2002
  • A FE model is to develop a personalized biomechanical model of the scoliotic spine that will allow the design of clinical test providing optimal estimation of the post-operation results. A flexible multi-body model of the spine including rib cage, clavicle, and scapular was developed to simulate several mobility simulations. Vertebrae, clavicle and scapular were represented using rigid bodies and ribs and sternum were modeled as flexible bodies. Kinematical Joints and spring elements were used to represent the intervertebral disc and ligaments respectively. Postero-anterior and lateral radiographics of a scoliotic spine were used to represent a 3D reconstruction. CT data for same patient were also used to verify vertebrae rotation driven from postero-anterior and lateral radiographic images. Simulated results showed good reducibility almost uniformly distributed along the spinal segments. It was also found that boundary and loading conditions, required to mimic the operation procedures, were proven to be very sensitive parameters to its results rather than its mechanical properties

  • PDF

Wobbling Mass를 고려한 인체 진동 모텔의 개발 (Development of Human Body Vibration Model Including Wobbling Mass)

  • 김영은;백광현;최준희
    • 한국자동차공학회논문집
    • /
    • 제10권2호
    • /
    • pp.193-200
    • /
    • 2002
  • Simple spring-damper-mass models have been widely used to investigate whole-body vortical biodynamic response characteristics of the seated vehicle driver. Most previous models have not considered the effect of wobbling masses; i.e. heart, lungs, liver, intestine, etc. In this study, 4 -DOF seated driver model including one non-rigid mass representing wobbling visceral mass, 5-DOF model including intestine, and 10-DOF model including five lumbar vertebral masses were proposed. The model parameters were identified by a combinatorial optimization technique. simulated annealing method. The objective function was chosen as the sum of error between model response of seat-to-head transmissibility and driving point mechanical impedance and those of experimental data for subjects seated erect without backrest support. The model response showed a good agreement with the experimental response characteristics. Using a 10-DOF model, calculated resonance frequency of lumbar spine at 4Hz was matched well with experimental results of Panjabi et al.

충격력에 대한 인체의 머리와 목의 동력학적 응답특성 (Characteristiis of Dynamic Response in the Human Head and Neck to Implusive Loading)

  • 김영은;김정훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권4호
    • /
    • pp.491-498
    • /
    • 1995
  • A numerical human head/neck model was constructed for analyzing the implication in decleration injuries. This model consists of nine rigid bodies representing the head, cervical vertebrae C1-C7, and T1. These rigid bodies were connected by intervertebral disks described by massless beam elements. Muscles and ligaments were also incoperated in the model represented by nonlinear spring and viscoblastic element respectively Agreement of the analytical kinematic response with the results of experimental data from a volunteer run was satisfactory. Moreover, possible injury estimation from the calculated moment, force variations in the disc, and force variation in ligaments matched well with clinical observations.

  • PDF

안전방출밸브 개발과 용량인증 사례 (Experience for development and capacity certification of safely relief valves)

  • 김칠성;노희선;김강태;김지헌;김종수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.492-500
    • /
    • 2004
  • The purpose of this study is localization of safety relief valves fur Nuclear Service through technical development with overall design, fabrication, inspection, capacity certification test and functional qualification test of safety relief valves in accordance with KEPIC MN Code(or ASME Sec.III ). The safely relief valve is the important equipment used to protect the pressure vessel, the steam generator and the other pressure facility from overpressure by discharging the operating medium when the pressure of system is reaching the design pressure of the system. But we're depending on technology of the other country up to the present time. Because we don't have our own technologies, we have been spent the great time and money on installing and repairing safety relief valve at nuclear power plant. Therefore we have to achieve the development of safety relief valves for Nuclear Service with our own technologies.

  • PDF

영천댐의 식물플랑크톤 군집과 환경요인의 동태 (Dynamics of Phytoplankton Community and the Physico-chemical Environmental Factors in Youngchun Dam)

  • 김숙찬;김한순
    • ALGAE
    • /
    • 제19권3호
    • /
    • pp.227-234
    • /
    • 2004
  • A study on the dynamics of phytoplankton community and the physico-chemical environmental factors was performed biweekly from April 1998 to March 1999 in Youngchun Dam. A total 72 phytoplankton taxa was identified and dominant taxa were blue-green algae and diatoms. The highest value of phytoplankton standing crop (24,826cells·ml$^{-1}$) was observed in September 7, 1998, the blooming period of blue-green algae Phormidium sp., while the lowest (318cells·ml$^{-1}$) was measured in June 18, 1999. The phytoplankton communities were dominated by blue-green algae of Anabaena planktonica, Microcystis aeruginosa and Phormidium sp. during the summer and autumn periods and were dominated by diatoms of Synedra acus and Aulacoseira spp. during the spring and winter periods. Secchi disc transparency, chlorophyll-a, total nitrogen, total phosphorus and silicate concentration were varied in the ranges of 0.4-2.5 m, 2.4-32.2mg·m$^{-1}$, 0.845-2.352mg·l$^{-1}$, 0.005-0.093mg·l$^{-1}$, 0.2-15.7mg·l$^{-1}$, respectively. The trophic status of Youngchun Dam were estimated eutrophic according to Lake Trophic States Index (LTSI).

ORTHOPEDIC FORCE에 의한 백서악관절 주위조직의 변화에 대한 조직학적 연구 (A HISTOLOGICAL STUDY ON THE CHANCES OF THE SURROUNDING TISSUE IN MANDIBULAR JOINT BY THE ORTHOPEDIC FORCE IN RATS)

  • 이백민
    • 대한치과교정학회지
    • /
    • 제13권2호
    • /
    • pp.155-163
    • /
    • 1983
  • Many different appliances have been used to move teeth or to attempt to inhibit or stimulate growth of the jaws. Especially, Orthopedic force was used to apply a constant force on the mandible. Various orthopedic forces bring the changes of surrounding tissue, growth and development on the mandibular joint. Author carried out this study to find the histological changes of the mandibular joint in rats when the mandible applied posterior displacement. For the purpose of this study, $009\times036inch$ closed coil spring and 030inch orthopedic wire were used between the post occipital region and the chin region in order to render the orthopedic forces, posteriorly. The experimental animals vu. used 1 month old (GroupI), 3 months old (Group II), and 12 months old (Group III) rats. Following results were obtained; 1. At the beginning of the experimental Group I, there were predominant increment of Cartilage layer in the posterior parts of condylar head. Especially, the mature chondrocyte zone was increased. 2. In the experimental Group II, the chondroblastic zone was decreased while it showed slightly increased mature cartilage zone. 3. In the experimental Group III, the mature chondrocyte zone was disappeared gradually and there was a tendency to reduce the endochondral bone formation in condylar head. 4. After 30 days of experimental Group I and in experimental Group II, there was a tendency to decrease the immature cellular zone in the glenoid fossa by pressure. 5. There were no histological changes in the articular disc by pressure.

  • PDF

유압 회로를 이용한 초고속 스핀들의 언클램핑(unclamping) 시간 저감 방안 연구 (A Study on the Decrease of the Unclamping time using Hydraulic Circuit)

  • 정원지;이춘만;조영덕;황영국;정동원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1745-1748
    • /
    • 2005
  • According to the demand of the high productivity, the interest of manufacturing skills is growing in industrial society. Especially the high speed spindle in machining center becomes important these days. The exchange time of the tool in machining center usually calls T-T(tool to tool) time. Detailly explaning, It is influenced by the unclamping time. Affecting factors of the unclamping time are various(the hydraulic system, drawbar mass, a flow meter, disc spring, a piston diameter, pipe diameters, and so on). In this study, we could find factors that decrease the unclamping time and verify it for softwares.(AMESim $4.0^{(R)}$ & visual Nastran $4D^{(R)}$)

  • PDF