• Title/Summary/Keyword: Disaster Prevention Systems

Search Result 319, Processing Time 0.023 seconds

Study of the Risk of Ignition due to Internal Combustion Engines in Areas with Potentially Explosive Gas Atmospheres (잠재적 폭발위험장소에서 내연기관에 의한 점화 위험성에 관한 연구)

  • Kim, Yun Seok;Rie, Dong Ho
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.1-8
    • /
    • 2016
  • Safety management in hazardous areas with potentially explosive gas atmospheres (here in after referred to as hazardous areas) in large scale facilities dealing with combustible or flammable materials at home and abroad is very important (significant) for the coexistence of the company and local society based on business continuity management (BCM) and reliance. For the safety management in hazardous areas, two systems are mainly used: (1) the control system for the prevention of combustible or flammable substances and (2) the explosion proof system for the elimination of ignition sources when flammable gases are leaked to inhibit the transition to fire or explosion accidents. While technology and regulations on explosion proof facilities or devices for electrical ignition sources are well developed and defined, those for thermal ignition sources need to be more developed and established. In this study, the internal combustion engine in hazardous areas was investigated to determine the risk of ignition. For this purpose, document searches were conducted on the relevant international standards and accidents cases and risk analysis reports. In addition, this study assessed the application cases of the diesel engine's safety equipment, such as spark arresters regarding the site of process safety management (PSM) system in central Korea. To practically apply these results to the hydrocarbon industry, the safety management method for explosion prevention in hazardous areas was provided by risk identification for ignition sources of internal combustion engines, such as diesel engines.

A Study on the Contents for Operation of Tunnel Management Systems Using a View Synthesis Technology (영상정합 기술을 활용한 터널관리시스템의 운영 효율성 제고를 위한 콘텐츠 연구)

  • Roh, Chang-gyun;Park, Bum-Jin;Kim, Jisoo
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.6
    • /
    • pp.507-515
    • /
    • 2016
  • In South Korea, there are a large number of tunnels because of the mountainous terrain, and to overcome this characteristics, lengths of tunnels are more longer than existing tunnels. The need to improvement current tunnel management contents is giving rise for accidents in tunnel section is continuously increased although lots of efforts to reduce the accidents. Conventionally, disaster prevention have been focused on the Tunnel Management Systems, tunnel operators generally tend to depend on CCTV images for most contents of detailed traffic flow managing. In this paper, investigation about current Tunnel Management Systems contents using IPA survey was conducted, and Priority Improvement Contents(Accident Situation Management Support, 2nd Accident Management Support, Traffic Flow Monitoring), which importance are high, but satisfaction are low, are deducted. Also, CCTV images, lack intuitive understanding, are judged as a main cause of low satisfaction of those contents. To overcome those limitations of the existing Tunnel Management Systems, this study sought to develop a technology for the synthesis of road images to derive traffic information from synthesis images, and the contents improvement stragegy is established. Tunnel operators-oriented satisfaction survey on new contents was carried out, and scored 4.2 on a 5-point scale. This has confirmed that the availability of new contents and at this stage, with pushing ahead of long-tunnels and undersea tunnels construction, politic applications are expected.

Design of an Integrated Monitoring System for Constructional Structures Based on Mobile Cloud in Traditional Towns with Local Heritage

  • Min, Byung-Won;Oh, Sang-Hoon;Oh, Yong-Sun;Okazaki, Yasuhisa;Yoo, Jae-Soo;Park, Sun-Gyu;Noh, Hwang-Woo
    • International Journal of Contents
    • /
    • v.11 no.2
    • /
    • pp.37-49
    • /
    • 2015
  • Sensors, equipment, ICT facilities and their corresponding software have a relatively short lifetime relative to that of constructional structure, so these devices have to be continuously fixed or exchanged during maintenance and management. Furthermore, software or analysis tools should be periodically upgraded according to advances in ICT and analysis technology. Conventional monitoring systems have serious problems in that it is difficult for site engineers to modify or upgrade hardware and analysis algorithms. Moreover, we depend on the original system developer when we want to modify or upgrade inner program structures. In this paper, we propose a novel design for integrated maintenance and management of a monitoring system by applying the mobile cloud concept. The system is intended for use in disaster prevention of constructional structures, including bridges, tunnels, and in traditional buildings in a local heritage village, we analyze the status of these structures over a long term or a short-term period as well as in disaster situations. Data are collected over a mobile cloud and future expectations are analyzed according to probabilistic and statistical techniques. We implement our integrated monitoring system to solve the existing problems mentioned above. The final goal of this study is to design and implement a monitoring system for more than 10,000 structures spread within Korea. Furthermore, we can specifically apply the monitoring system presented here to a bridge made from timber in Asan Oeam Village and a traditional house in Andong Hahoe Village to monitor for possible disasters. The entire system design and implementation can be developed on the LinkSaaS platform and the monitoring services can also be implemented on the platform. We prove that the proposed system has good performance by performing a TTA authentication test, web accommodation test, and operation test using emulated data.

A Study on the Improvement Plan of Electrostatic Safety Management Level through Injury Analysis (재해분석을 통한 정전기 안전관리 수준 향상 방안 연구)

  • Choi, Sang-won;Jeong, Seong-Choon;Park, Jae Suk;Yang, Jeong Yeol;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.37-45
    • /
    • 2019
  • The characteristic of fire and explosion related to electrostatic discharge is that it is difficult to reproduce the electrostatic charge and discharge phenomenon in addition to the large human and material damage. Therefore, in order to prevent accidents and disasters related to electrostatic in fire and explosion hazard areas, it is important to manage the level of electrostatic in a safe manner from the perspective of system between industrial facilities and human bodies. Rule 325 of the Occupational Safety and Health Regulations, "Prevention of Fire / Explosion due to Electrostatic", requires the use of grounding, conductive materials, humidification and electrification in order to prevent the risk of disaster caused by static explosion and electrostatic in the production process. In order to comply with these measures, related technologies, standards and systems are needed from the viewpoint of preventive measures related to electrostatic in fire and explosion hazard areas, but in Korea, it is still insufficient. Therefore, technical, institutional and managerial measures are needed as a precautionary measure to improve the level of ESD safety in fire and explosion hazard areas and prevent electrostatic related injury. In Korea, we analyzed the current status and characteristics of electrostatic related disaster by using the statistics of industrial accident and fire statistics of the Ministry of Employment and Labor. We also analyzed the current status and characteristics of electrostatic related disasters in Japan using JNIOSH accidents and disasters investigation cases and JNIOSH fire accident data of Japan Fire Bureau. The purpose of this study is to compare and analyze the current status of electrostatic related accidents and disasters in Korea and Japan in order to improve the safety management of electrostatic in fire and explosion hazard areas. In order to prevent accidents and disasters in the industrial field, The technical, institutional, and managerial measures to manage the level of electrostatic in a safe state were derived from the system point of view.

A Case Study on Performance Analysis of Antimicrobial Copper Film Attaching to Window for Responding to COVID-19 and Others (코로나19 등 대응을 위한 "유리창 부착용 항바이러스 동필름" 성능분석 사례연구)

  • Kim, Seong Je
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.1
    • /
    • pp.23-40
    • /
    • 2021
  • In the era of the global coronal 19 pandemic, there is a risk of cross-infection in hospitals at the stage where treatments and vaccines are currently being developed and marketed, so individuals should enhance their acquired immunity and generalize their living systems by the performance of copper ions in the social environment. In order to prevent the spread of infection, the need for anti-bacterial film and its efficacy were analyzed through anti-viral performance tests based on research and development cases of worldwide and immemorial time. he Korea Construction Research Institute (KCL) has received anti-bacterial performance certification and anti-viral test scores from the "National Approval Performance Certification Agency." At the time, NCCP 43326 Human Corona virus (BetaCoV/Korea/KCDC03/2020), which was approved by the Centers for Disease Control and Prevention, was introduced to ensure that the activity rate of infected cells was satisfied in the anti-viral performance test. Anti-proliferation measures for the Corona 19 virus require a quality clinical trial study comparing the experimental group within the glass space where the antiviral copper film is constructed with the comparator of the same condition without copper film.

Comparison of Liquefaction Assessment Results with regard to Geotechnical Information DB Construction Method for Geostatistical Analyses (지반 보간을 위한 지반정보DB 구축 방법에 따른 액상화 평가 결과 비교)

  • Kang, Byeong-Ju;Hwang, Bum-Sik;Bang, Tea-Wan;Cho, Wan-Jei
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.4
    • /
    • pp.59-70
    • /
    • 2022
  • There is a growing interest in evaluating earthquake damage and determining disaster prevention measures due to the magnitude 5.8 earthquake in Pohang, Korea. Since the liquefaction phenomena occurred extensively in the residential area as a result of the earthquake, there was a demand for research on liquefaction phenomenon evaluation and liquefaction disaster prediction. Liquefaction is defined as a phenomenon where the strength of the ground is completely lost due to a sudden increase in excess pore water pressure caused due to large dynamic stress, such as an earthquake, acting on loose sand particles in a short period of time. The liquefaction potential index, which can identify the occurrence of liquefaction and predict the risk of liquefaction in a targeted area, can be used to create a liquefaction hazard map. However, since liquefaction assessment using existing field testing is predicated on a single borehole liquefaction assessment, there has been a representative issue for the whole targeted area. Spatial interpolation and geographic information systems can help to solve this issue to some extent. Therefore, in order to solve the representative problem of geotechnical information, this research uses the kriging method, one of the geostatistical spatial interpolation techniques, and constructs a geotechnical information database for liquefaction and spatial interpolation. Additionally, the liquefaction hazard map was created for each return period using the constructed geotechnical information database. Cross validation was used to confirm the accuracy of this liquefaction hazard map.

Practical Construction of Tsunami Inundation Map to Link Disaster Forecast/Warning and Prevention Systems (예경보와 방재시스템의 연계를 위한 지진해일 범람도의 실용적 작성)

  • Choi, Jun-Woo;Kim, Kyung-Hee;Jeon, Young-Joon;Yoon, Sung-Bum
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.2
    • /
    • pp.194-202
    • /
    • 2008
  • In general, forecast tsunami heights announced for tsunami warning are computed by using a linear tsunami model with coarse grids which leads the underestimation of inundation area. Thus, an accurate tsunami inundation map corresponding the forecast tsunami height is needed for an emergency evacuation plan. A practical way to construct a relatively accurate tsunami inundation map was proposed in this study for the quantitative forecast of inundation area. This procedure can be introduced as in the followings: The fault dislocations of potential tsunami sources generating a specific tsunami height near an interested area are found by using a linear tsunami model. Based on these fault dislocations, maximum inundation envelops of the interested area are computed and illustrated by using nonlinear inundation numerical model. In this study, the tsunami inundation map for Imwon area was constructed according to 11 potential tsunami sources, and the validity of this process was examined.

Environment Monitoring System Using RF Sensor (RF 센서를 이용한 해양 환경 관리 시스템)

  • Cha, Jin-Man;Park, Yeoun-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.896-898
    • /
    • 2012
  • Recently, many countries are making efforts for the development of ocean resources because the necessity and importance of the ocean resources are increased. Underwater sensor networks have emerged as a very powerful technique for many applications, including monitoring, measurement, surveillance and control and envisioned to enable applications for oceanographic data collection, ocean sampling, environmental and pollution monitoring, offshore exploration, disaster prevention, tsunami and seaquake warning, assisted navigation, distributed tactical surveillance, and mine reconnaissance. The idea of applying sensor networks into underwater environments (i.e., forming underwater sensor networks) has received increasing interests in monitoring aquatic environments for scientific, environmental, commercial, safety, and military reasons. The data obtained by observing around the environment are wireless-transmitted by a radio set with various waves. According to the technical development of the medium set, some parameters restricted in observing the ocean have been gradually developed with the solution of power, distance, and corrosion and watertight by the seawater. The actual matters such as variety of required data, real-time observation, and data transmission, however, have not enough been improved just as various telecommunication systems on the land. In this paper, a wireless management system will be studied through a setup of wireless network available at fishery around the coast, real-time environmental observation with RF sensor, and data collection by a sensing device at the coastal areas.

  • PDF

Analysis of Risk Factors of Sinkholes with Geospatial Information (지형공간정보를 이용한 싱크홀의 위험요인 분석)

  • Kim, Dong-Moon
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.4
    • /
    • pp.37-43
    • /
    • 2016
  • Sinkholes happen in increasingly higher frequency in downtown areas with a concentration of social infrastructure these days. Most sinkholes occur around the living areas of citizens, which calls for a systematic countermeasure plan for urban development and underground water management, which are parts of the main causes of sinkholes. This study thus set out to analyze the risk factors of sinkholes in the subject area by using geospatial information deeply connected to sinkholes both directly and indirectly. The geospatial information used in analysis was obtained by examining the causes of sinkholes from a topographical perspective. Collected data were treated and analyzed with a range of spatial analysis tools based on GIS. The findings show that topographical factors had significant relations with sinkhole causes and raise a need to manage all kinds of pipe networks underground, the movement characteristics of underground water levels, and other topographical features. The findings may serve as data to support decision-making processes in the field of urban disaster prevention and call for extensive research to incorporate hydro-geomorphology and spatial modeling.

PR-MAC Protocol based on Priority in Underwater Acoustic Sensor Networks (수중 음파 센서 네트워크에서 우선순위 기반의 PR-MAC 포로토콜)

  • Cho, Hui-Jin;NamGung, Jung-Il;Yun, Nam-Yeol;Park, Soo-Hyun;Ryuh, Young-Sun
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.2
    • /
    • pp.258-268
    • /
    • 2011
  • Underwater acoustic sensor networks can be used disaster prevention and environmental monitoring systems in underwater environments. Because, the underwater environment is different from the ground, the long propagation delay, low transfer rates and limited bandwidth characteristics should be considered. In this, paper will propose the MAC protocol that allocates time slot into each node according to priority policy through the period of contention-free slot reservation in underwater acoustic sensor networks in order to avoid collision and minimize energy consumption waste. We perform mathematical analysis to evaluate the performance of the proposed protocol with regard to the collision probability, the energy consumption by collision, throughput and channel utilization. We compare the proposed protocol with the conventional protocol, and the performance results show that the proposed protocol outperforms the conventional protocol.